DOI QR코드

DOI QR Code

Fast-Transient Repetitive Control Strategy for a Three-phase LCL Filter-based Shunt Active Power Filter

  • Zeng, Zheng (College of Electrical Engineering, Zhejiang University) ;
  • Yang, Jia-Qiang (College of Electrical Engineering, Zhejiang University) ;
  • Chen, Shi-Lan (College of Electrical Engineering, Zhejiang University) ;
  • Huang, Jin (College of Electrical Engineering, Zhejiang University)
  • Received : 2013.03.28
  • Accepted : 2013.12.30
  • Published : 2014.03.20

Abstract

A fast-transient repetitive control strategy for a three-phase shunt active power filter is presented in this study to improve dynamic performance without sacrificing steady-state accuracy. The proposed approach requires one-sixth of the fundamental period required by conventional repetitive control methods as the repetitive control time delay in the synchronous reference frames. Therefore, the proposed method allows the system to achieve a fast dynamic response, and the program occupies minimal storage space. A proportional-integral regulator is also added to the current control loop to eliminate arbitrary-order harmonics and ensure system stability under severe harmonic distortion conditions. The design process of the corrector in the fast-transient repetitive controller is also presented in detail. The LCL filter resonance problem is avoided by the appropriately designed corrector, which increases the margin of system stability and maintains the original compensation current tracking accuracy. Finally, experimental results are presented to verify the feasibility of the proposed strategy.

Keywords

References

  1. H. Akagi, "Active harmonic filters," in Proc. the IEEE, Vol. 93, No. 12, pp. 2128-2141, Dec. 2005. https://doi.org/10.1109/JPROC.2005.859603
  2. M. Liserre, F. Blaabjerg, and S. Hansen, "Design and control of an LCL-filter-based three-phase active rectifier," IEEE Trans. Ind. Appl., Vol. 41, No.5, pp. 1281-1291, Sep./Oct. 2005. https://doi.org/10.1109/TIA.2005.853373
  3. T. Yi, C. L. Poh, W. Peng, H. C. Fook, G. Feng, and F. Blaabjerg, "Generalized design of high performance shunt active power filter with output LCL filter," IEEE Trans. Ind. Electron., Vol. 59, No. 3, pp. 1443-1452, Mar. 2012. https://doi.org/10.1109/TIE.2011.2167117
  4. D. Wojciechowski and R. Strzelecki, "High power, zero ripples active filtering system with power modules operating in parallel," in Electronics Conference (BEC), pp. 305-308, 2010.
  5. O. Vodyakho and C. C. Mi, "Three-level inverter-based shunt active power filter in three-Phase three-wire and four-wire systems," IEEE Trans. Power Electron., Vol. 24, No. 5, pp. 1350-1363, May 2009. https://doi.org/10.1109/TPEL.2009.2016663
  6. M. I. M. Montero, E. R. Cadaval, and F. B. Gonzalez, "Comparison of control strategies for shunt active power filters in three-phase four-wire systems," IEEE Trans. Power Electron., Vol. 22, No. 1, pp. 229-236, Jan. 2007. https://doi.org/10.1109/TPEL.2006.886616
  7. A. Luo, Z. Shuai, W. Zhu, R. Fan, and C. Tu, "Development of hybrid active power filter based on the adaptive fuzzy dividing frequency-control method," IEEE Trans. Power Del., Vol. 24, No. 1, pp. 424-432, Jan. 2009. https://doi.org/10.1109/TPWRD.2008.2005877
  8. J. Matas, L. G. de Vicuna, J. Miret, J. M. Guerrero, and M. Castilla, "Feedback linearization of a single-phase active power filter via sliding mode control," IEEE Trans. Power Electron., Vol. 23, No. 1, pp. 116-125, Jan. 2008. https://doi.org/10.1109/TPEL.2007.911790
  9. B. Singh and J. Solanki, "An implementation of an adaptive control algorithm for a three-phase shunt active filter, " IEEE Trans. Ind. Electron., Vol. 56, No.8, pp. 2811-2820, Aug. 2009.
  10. I. J. Gabe, V. F. Montagner, and H. Pinheiro, "Design and implementation of a robust current controller for VSI connected to the grid through an LCL filter," IEEE Trans. Power Electron., Vol.24, No. 6, pp. 1444-1452, Jun. 2009. https://doi.org/10.1109/TPEL.2009.2016097
  11. Z. Wang, C. Xie, C. He, and G. Chen, "A waveform control technique for high power shunt active power filter based on repetitive control algorithm," in Proc. IEEE APEC, pp. 361-366, 2010.
  12. R. I. Bojoi, G. Griva, V. Bostan, M. Guerriero, F. Farina, and F. Profumo, "Current control strategy for power conditioners using sinusoidal signal integrators in synchronous reference frame," IEEE Trans. Power Electron., Vol. 20, No.6, pp. 1402-1412, Nov. 2005. https://doi.org/10.1109/TPEL.2005.857558
  13. B. Zhang, D. Wang, K. Zhou, and Y. Wang, "Linear phase lead compensation repetitive control of a CVCF PWM inverter," IEEE Trans. Ind. Electron., Vol. 55, No. 4, pp. 1595-1602, Apr. 2008. https://doi.org/10.1109/TIE.2008.917105
  14. G. Escobar, A. A. Valdez, J. Leyva-Ramos, and P. Mattavelli, "Repetitive-based controller for a UPS inverter to compensate unbalance and harmonic distortion," IEEE Trans. Ind. Electron., Vol. 54, No. 1, pp. 504-510, Feb. 2007.
  15. T. Xin, K. M. Tsang, and W. L. Chan, "A power quality compensator with DG interface capability using repetitive control," IEEE Trans. Energy Convers., Vol. 27, No. 2, pp. 213-219, Jun. 2012. https://doi.org/10.1109/TEC.2012.2183874
  16. A. Garcia-Cerrada, O. Pinzon-Ardila, V. Feliu-Batlle, P. Roncero-Sanchez, and P. Garcia-Gonzalez, "Application of a repetitive controller for a three-phase active power filter," IEEE Trans. Power Electron., Vol. 22, No.1, pp. 237-246, Jan. 2007. https://doi.org/10.1109/TPEL.2006.886609
  17. R. Costa Castello, R. Grino, R. Cardoner Parpal, and E. Fossas, "High-performance control of a single-phase shunt active filter," IEEE Trans. Control Syst. Technol., Vol. 17, No. 6, pp. 1318-1329, Nov. 2009. https://doi.org/10.1109/TCST.2008.2007494
  18. J. Miret, M. Castilla, J. Matas, J. M. Guerrero, and J. C. Vasquez, "Selective harmonic-compensation control for single-phase active power filter with high harmonic rejection," IEEE Trans. Power Electron., Vol. 56, No.8, pp. 3117-3127, Aug. 2009.
  19. Z. Zou, Z. Wang, M. Cheng, and Y. Yang, "Active power filter for harmonic compensation using a digital dual-mode-structure repetitive control approach," in Proc. IEEE PEDG, pp. 161-166, 2012.
  20. Z. Zeng, J. Yang, and N. Yu, "Research on PI and repetitive control strategy for shunt active power filter with LCL filter," in Proc. IEEE IPEMC, pp. 2833-2837, 2012.
  21. R. Costa-Castello and R. Grino and E. Fossas, "Odd-harmonic digital repetitive control of a single-phase current active filter," IEEE Trans. Power Electron., Vol. 19, No. 4, pp. 1060-1068, Jul. 2004. https://doi.org/10.1109/TPEL.2004.830045
  22. R. Grino, R. Cardoner, R. Costa-Castello, and E. Fossas, "Digital repetitive control of a three-phase four-wire shunt active filter," IEEE Trans. Ind. Electron., Vol. 54, No.3, pp. 1495-1503, Jun. 2007. https://doi.org/10.1109/TIE.2007.894790
  23. W. Lu, K. Zhou, M. Cheng, Y. Yang, and S. Fan, "Parallel structure repetitive controller for CVCF three-phase PWM inverter," in Proc. IEEE APEC, pp. 207-210, 2012.
  24. G. Escobar, P. G. Hernandez-Briones, P. R. Martinez, M. Hernandez-Gomez, and R. E. Torres-Olguin, "A repetitive-based controller for the compensation of $61{\pm}1$ harmonic components," IEEE Trans. Ind. Electron., Vol. 55, No.8, pp. 3150-3158, Aug. 2008.
  25. S. Jiang, D. Cao, Y. Li, J. Liu, and F. Z. Peng, "Low-THD, fast-transient, and cost-effective synchronous-frame repetitive controller for three-phase UPS inverters," IEEE Trans. Power Electron., Vol. 27, No.6, pp. 2994-3005, Jun. 2012. https://doi.org/10.1109/TPEL.2011.2178266
  26. G. F. Teng, G. C. Xiao, L. L. Hu, Y. Lu, and Y. R. Kafle, "Control Strategy Based on Equivalent Fundamental and Odd Harmonic Resonators for Single-Phase DVRs," Journal of Power Electronics, Vol. 12, No.4, pp. 654-663, Jul. 2012. https://doi.org/10.6113/JPE.2012.12.4.654

Cited by

  1. Versatile UPQC Control System with a Modified Repetitive Controller under Nonlinear and Unbalanced Loads vol.15, pp.4, 2015, https://doi.org/10.6113/JPE.2015.15.4.1093
  2. An Efficient FPGA based Real-Time Implementation Shunt Active Power Filter for Current Harmonic Elimination and Reactive Power Compensation vol.10, pp.4, 2015, https://doi.org/10.5370/JEET.2015.10.4.1655
  3. Parallel Structure Fractional Repetitive Control for PWM Inverters vol.62, pp.8, 2015, https://doi.org/10.1109/TIE.2015.2402117
  4. High-Performance Grid Simulator Using Parallel Structure Fractional Repetitive Control vol.31, pp.3, 2016, https://doi.org/10.1109/TPEL.2015.2441732
  5. Topologies, generalized designs, passive and active damping methods of switching ripple filters for voltage source inverter: A comprehensive review vol.62, 2016, https://doi.org/10.1016/j.rser.2016.04.006
  6. Analysis and Application of Repetitive Control Scheme for Three-Phase Active Power Filter with Frequency Adaptive Capability vol.11, pp.3, 2016, https://doi.org/10.5370/JEET.2016.11.3.618
  7. An Inductance Voltage Vector Control Strategy and Stability Study Based on Proportional Resonant Regulators under the Stationary αβ Frame for PWM Converters vol.16, pp.3, 2016, https://doi.org/10.6113/JPE.2016.16.3.1110
  8. Active Damping of LLCL Filters Using PR Control for Grid-Connected Three-Level T-Type Converters vol.15, pp.3, 2015, https://doi.org/10.6113/JPE.2015.15.3.786
  9. A novel serial structure repetitive control strategy for shunt active power filter pp.0332-1649, 2019, https://doi.org/10.1108/COMPEL-02-2018-0079