References
- Aizawa, S. and Fukao, Y. et al. (1988), "An experimental study on the active mass damper", Proceedings of the 9th World Conference on Earthquake Engineering, Tokyo, Japan. August.
- Cao, H., Reinhorn, A.M. and Soong, T.T. (1998), "Design of an active mass damper for a tall TV tower in Nanjing, China", Eng. Struct., 20(3), 134-143. https://doi.org/10.1016/S0141-0296(97)00072-2
- Chunyan, J., Huajun, L. and Qingmin, M. (2004), "Active control strategy for offshore structures accounting for AMD constraints", High Technol. Lett., 10(4), 63-68.
- Fujita, T., Kamada, T. and Masaki, N. (1992), "Fundamental study of active mass damper using multistage rubber bearing and hydraulic actuator for vibration control of tall buildings: part 1 study on control law for the active mass damper", Trans. JSME, 58, 87-91. https://doi.org/10.1299/kikaic.58.87
- Ikeda, Y., Sasaki, K., Sakamoto, M. and Kobori, T. (2001), "Active mass driver system as the first application of active structural control", Earthq. Eng. Struct. D. , 30(11),1575-1595. https://doi.org/10.1002/eqe.82
- Ikeda, Y. (2009), "Active and semi-active vibration control of buildings in Japan - Practical applications and verification", Struct. Control Health Monit, 16(7-8), 703-723. https://doi.org/10.1002/stc.315
- Kawai, N. and Ohtsuka, M. et al. (1994), "A development of active response control system. Part 3: shaking table test results on variable gain control method", Trans. AIJ annual meeting, 895-896. (in Japanese).
- Nishitani, A. (1998), "Application of active structural control in Japan", Prog. Struct. Eng. Mater., 1(3), 301-307. https://doi.org/10.1002/pse.2260010312
- Nishitanil, A. and Inoue, Y. (2001), "Overview of the application of active/semiactive control to building structures in Japan", Earthq. Eng. Struct. D., 30(11), 1565-1574. https://doi.org/10.1002/eqe.81
- Nagashima, I. and Shinozaki, Y. (1997), "Variable gain feedback control technology of active mass damper and its application to hybrid structural control", Earthq. Eng. Struct. D., 26(8), 815-838. https://doi.org/10.1002/(SICI)1096-9845(199708)26:8<815::AID-EQE678>3.0.CO;2-E
- Ou, J.P. (2003), Structural vibration control-active, semi-active and intelligent control [M], Science Press, 56-57 and 98-125 (in Chinese).
- Soong, T.T. and Costantinou, M.C. (Eds.) (1994), Passive and active structural vibration control in civil engineering, CISM Lecture Notes, Springer-Verlag New York, USA.
- Suzuki, T. and Kageyama, M. et al. (1993), "Active vibration control system for high-rise buildings. Part 14: vibration test on variable feedback gain control", Trans. AIJ annual meeting, 735-754 (in Japanese).
- Yamamoto, M., Aizawa, S., Higashino, M. and Toyama, K. (2001), "Practical applications of active mass dampers with hydraulic actuator", Earthq. Eng. Struct. D., 30(11), 1697-1717. https://doi.org/10.1002/eqe.88
- Yao, J.T.P. (1972), "Concept of structure control", J. Struct. Division, ASCE, 98(7), 1567-1574.
- Yoshida, K., Nishimura, Y. and Yonezawa, Y. (1986), "Variable gain feedback control for linear sampled-data systems with bounded control", Control Theory Adv. Technol., 2,313-323.
Cited by
- An Observer-Based Controller with a LMI-Based Filter against Wind-Induced Motion for High-Rise Buildings vol.2017, 2017, https://doi.org/10.1155/2017/1427270
- Influence analysis of time delay to active mass damper control system using pole assignment method vol.80, 2016, https://doi.org/10.1016/j.ymssp.2016.04.008
- Influence Analysis of a Higher-Order CSI Effect on AMD Systems and Its Time-Varying Delay Compensation Using a Guaranteed Cost Control Algorithm vol.7, pp.4, 2017, https://doi.org/10.3390/app7040313
- Effects of control-structure interaction in active mass driver systems with electric torsional servomotor for seismic applications vol.15, pp.4, 2017, https://doi.org/10.1007/s10518-016-0021-6
- Smart tuned mass dampers: recent developments vol.13, pp.2, 2014, https://doi.org/10.12989/sss.2014.13.2.173
- A Review on Adaptive Methods for Structural Control vol.10, pp.None, 2016, https://doi.org/10.2174/1874149501610010653
- Velocity feedback for controlling vertical vibrations of pedestrian-bridge crossing. Practical guidelines vol.22, pp.1, 2014, https://doi.org/10.12989/sss.2018.22.1.095
- An observer‐based fault tolerance control system with a static filter and its application to high‐rise buildings vol.2, pp.6, 2014, https://doi.org/10.1002/eng2.12174