DOI QR코드

DOI QR Code

Smart tuned mass dampers: recent developments

  • 발행 : 2014.02.25

초록

This special issue focuses on Smart Tuned Mass Dampers (STMD) that are either active or smart or semi-active in nature. Active tuned mass dampers or active mass dampers have found wide acceptance and have been implemented in many tall buildings and long span bridges. Recently researchers have developed a new class of smart tuned mass dampers using either variable stiffness and/or variable damping to effect the change in instantaneous frequency and damping. Since tuning plays a central role in STMDs it is of great current interest thus the topic of this special issue. Discussions of recent active and smart TMD implementations in tall buildings and bridges are also included.

키워드

참고문헌

  1. Abe, M, and Igusa, T. (1996), "Semi-active dynamic vibration absorbers for controlling transient response", J. Sound Vib., 198, 547-569. https://doi.org/10.1006/jsvi.1996.0588
  2. Arrigan, J., Huang, C., Staino, A., Basu, B. and Nagarajaiah, S. (2014), "A frequency tracking semi-active algorithm for control of edgewise vibrations in wind turbine blades", Smart Struct. Syst., 13(2), 177-201. https://doi.org/10.12989/sss.2014.13.2.177
  3. Bonello, P., Brennan, M.J., Elliott, S.J., Vincent, J.F.V. and Jeronimidis, G. (2005), "Designs for an adaptive tuned vibration absorber with variable shape stiffness element", Proc. R. Soc. A., 461, doi:10.1098/rspa.2005.1547.
  4. Chang, J.C.H. and Soong, T.T. (1980), "Structural control using active tuned mass damper", J. Eng. Mech. - ASCE, 106, 1091-1099.
  5. Contreras, M.T., Pasala, D,T.R. and Nagarajaiah, S. (2014), "Adaptive length SMA pendulum smart tuned mass damper performance in the presence of real time primary system stiffness change", Smart Struct. Syst., 13(2), 219-233. https://doi.org/10.12989/sss.2014.13.2.219
  6. Den Hartog, J.P. (1956), Mechanical vibrations (4th Ed.), McGraw-Hill, New York.
  7. Warburton, G.B. (1982), "Optimum absorber parameters for various combinations of response and excitation parameters", Earthq. Eng. Struct. D., 10, 381-401. https://doi.org/10.1002/eqe.4290100304
  8. Housner, G.W., Bergman, L.A., Caughey, T.K., Chassiakos, A.G., Claus, R.O., Masri, S.F. et al. (1997), "Structural control: past, present, and future", J. Eng. Mech. - ASCE, 123, 897-971. https://doi.org/10.1061/(ASCE)0733-9399(1997)123:9(897)
  9. Hrovat, D., Barak, P. and Rabins, M. (1983), "Semi-active versus passive or active tuned mass dampers for structural control", J. Eng. Mech. - ASCE., 109(3), 897-971.
  10. Jang, D.D., Jung, H.J. and Moon, Y.J. (2014), "Active mass damper system using time delay control algorithm for building structure with unknown dynamics", Smart Struct. Syst., 13(2), 281-303. https://doi.org/10.12989/sss.2014.13.2.281
  11. Kareem, A., Kijewski, T. and Tamura, Y. (1999), "Mitigation of motions of tall buildings with specific examples of recent applications", Wind Struct., 2(3), 201-251. https://doi.org/10.12989/was.1999.2.3.201
  12. Nagarajaiah, S. and Varadarajan, N. (2005), "Short time Fourier transform algorithm for wind response control of buildings with variable stiffness TMD", J. Eng. Struct., 27(3), 431-441. https://doi.org/10.1016/j.engstruct.2004.10.015
  13. Nagarajaiah, S. and Sonmez, E. (2007), "Structures with semiactive variable stiffness single/multiple tuned mass dampers", J. Struct. Eng., 133(1), 67-77. https://doi.org/10.1061/(ASCE)0733-9445(2007)133:1(67)
  14. Nagarajaiah, S. (2009), "Adaptive passive, semi-active, smart tuned mass dampers: identification and control using empirical mode decomposition, Hilbert transform, and short-term Fourier transform", Struct. Control Health Monit., 16(7-8), 800-841. https://doi.org/10.1002/stc.349
  15. Ormondroyd, J. and Den Hartog, J.P. (1928), "The theory of the dynamic vibration absorber", T. Am. Soc. Mech. Eng., 50, 9-22.
  16. Pasala, D.T.R. and Nagarajaiah, S. (2014), "Adaptive-length pendulum smart tuned mass damper using shape-memory-alloy wire for tuning period in real time", Smart Struct. Syst., 13(2), 203-217. https://doi.org/10.12989/sss.2014.13.2.203
  17. Pinkaew, T. and Fujino, Y. (2001), "Effectiveness of semi-active tuned mass dampers under harmonic excitation ", Eng. Struct., 23, 850-856. https://doi.org/10.1016/S0141-0296(00)00091-2
  18. Sadhu, A., Hazra, B. and Narasimhan, S. (2014), "Ambient modal identification of structures equipped with tuned mass dampers using parallel factor blind source separation", Smart Struct. Syst., 13(2), 257-280. https://doi.org/10.12989/sss.2014.13.2.257
  19. Spencer, B. and Nagarajaiah, S. (2003), "State of the art of structural control", J. Struct. Eng. - ASCE, 129(7), 845-856. https://doi.org/10.1061/(ASCE)0733-9445(2003)129:7(845)
  20. Sun, C. and Nagarajaiah, S. (2013), "Study on semi-active tuned mass damper with variable damping and stiffness under seismic excitations", Struct. Control Health Monit., DOI:10.1002/stc.1620.
  21. Sun, C., Nagarajaiah, S. and Dick, A.J. (2014), "Family of smart tuned mass dampers with variable frequency under harmonic excitations and ground motions: closed-form evaluation", Smart Struct. Syst., 13(2), 203-217. https://doi.org/10.12989/sss.2014.13.2.203
  22. Teng, J., Xing, H.B., Xiao, Y.Q., Liu, C.Y., Li, H. and Ou, J.P. (2014), "Design and implementation of AMD system for response control in tall buildings", Smart Struct. Syst., 13(2), 235-255. https://doi.org/10.12989/sss.2014.13.2.235
  23. Walsh, P.L. and Lamancusa, J.S.A (1992), "Variable stiffness vibration absorber for minimization of transient vibrations", J. Sound Vib., 158, 195-211. https://doi.org/10.1016/0022-460X(92)90045-Y
  24. Weber, F. (2013), "Dynamic characteristics of controlled MR-STMDs of Wolgograd Bridge", Smart. Mater. Struct., 22(9), Article Number: 095008, DOI: 10.1088/0964-1726/22/9/095008.
  25. Varadarajan, N. and Nagarajaiah, S. (2004), "Wind response control of building with variable stiffness tuned mass damper using EMD/HT", J. Eng. Mech. - ASCE, 130(4), 451-458. https://doi.org/10.1061/(ASCE)0733-9399(2004)130:4(451)
  26. Xu, H.B., Zhang, C.W., Li, H., Tan, P., Ou, J.P. and Zhou, F.L. (2014), "Active mass driver control system for suppressing wind-induced vibration of the Canton Tower", Smart Struct. Syst., 13(2), 305-318. https://doi.org/10.12989/sss.2014.13.2.305

피인용 문헌

  1. Seismic control response of structures using an ATMD with fuzzy logic controller and PSO method vol.51, pp.4, 2014, https://doi.org/10.12989/sem.2014.51.4.547
  2. Vibration control of smart TMD for retractable-roof spatial structure considering closed and open roof condition vol.17, pp.4, 2017, https://doi.org/10.1007/s13296-017-1221-x
  3. An electromagnetic vibration absorber with harvesting and tuning capabilities vol.22, pp.11, 2015, https://doi.org/10.1002/stc.1748
  4. Integration of health monitoring and vibration control for smart building structures with time-varying structural parameters and unknown excitations vol.15, pp.3, 2015, https://doi.org/10.12989/sss.2015.15.3.807
  5. Toward an adaptive vibration absorber using shape-memory alloys, for civil engineering applications 2017, https://doi.org/10.1177/1045389X17721031
  6. Seismic Response Control of Retractable-roof Spatial Structure Using Smart TMD vol.16, pp.4, 2016, https://doi.org/10.9712/KASS.2016.16.4.091
  7. Frequency-independent hysteretic dampers for mitigating wind-induced vibrations of tall buildings pp.15452255, 2019, https://doi.org/10.1002/stc.2341
  8. Analog active valve control design for non-linear semi-active resetable devices vol.19, pp.5, 2014, https://doi.org/10.12989/sss.2017.19.5.487
  9. 개폐식 대공간 구조물을 위한 스마트 TMD 설계기법 개발 vol.17, pp.3, 2014, https://doi.org/10.9712/kass.2017.17.3.107
  10. 스마트 TMD의 최적설계를 위한 파라메터 연구 vol.17, pp.4, 2017, https://doi.org/10.9712/kass.2017.17.4.123
  11. Motion-based design of TMD for vibrating footbridges under uncertainty conditions vol.21, pp.6, 2014, https://doi.org/10.12989/sss.2018.21.6.727
  12. Velocity feedback for controlling vertical vibrations of pedestrian-bridge crossing. Practical guidelines vol.22, pp.1, 2014, https://doi.org/10.12989/sss.2018.22.1.095
  13. Performance of passive and active MTMDs in seismic response of Ahvaz cable-stayed bridge vol.23, pp.5, 2019, https://doi.org/10.12989/sss.2019.23.5.449
  14. Stochastic stability control analysis of an inclined stay cable under random and periodic support motion excitations vol.23, pp.6, 2019, https://doi.org/10.12989/sss.2019.23.6.641