References
- AISC (2005), Steel Construction Manual, American Institute of Steel Construction (AISC), Chicago, IL.
- Chan, P. K. C., Jin, W., Gong, J. M., Demokan, M. S. (1999), Multiplexing of fiber Bragg grating sensors using an FMCW technique, IEEE Photonic Technology Letter, 11, 1470-1472. https://doi.org/10.1109/68.803082
- Choi, S. W., Lee, J., Oh, B. K., Park, H. S. (2013), Analytical models for estimation of the maximum strain of beam structures based on optical fiber bragg grating sensors, Journal of Civil Engineering and Management (Accepted).
- Grattan, K. T. V., Sun, T. (2000), Fiber optic sensors technology: an overview, Sensors and Actuators A: Physical, 82(1-3), 40-61. https://doi.org/10.1016/S0924-4247(99)00368-4
- Hahn, H. G., Ahn, H. J. (2012), A Study on Development of Structural Health Monitoring System for Steel Beams Using Strain Gauges, Journal of the Korea Institute for Structural Maintenance and Inspection, 16(1), 99-109 (in Korean). https://doi.org/10.11112/jksmi.2012.16.1.099
- Hampshire, T. A., Adeli, H. (2000), Monitoring the behavior of steel structures using distributed optical fiber sensor, Journal of Constructional Steel Research, 53, 267-281. https://doi.org/10.1016/S0143-974X(99)00043-7
- Lee, H. M., Park, H. S. (2013), Measurement of maximum strain of steel beam structures based on average strains from vibrating wire strain gages, Experimental Techniques, 37, 23-29. https://doi.org/10.1111/j.1747-1567.2011.00733.x
- Lee, J. H., Choi, S. W., Park, H. S. (2013), A Regressionbased Estimation of Strain Distribution for Safety Monitoring of the Steel Girder Subjected to Uncertain Loads, Journal of the Korea Institute for Structural Maintenance and Inspection, 17(2), 10-20 (in Korean).
- Li, H. N., Li, D. S., Song, G. B. (2004), Recent application of fiber optic sensors to health monitoring in civil engineering, Engineering Structures, 26(11), 1647-1657. https://doi.org/10.1016/j.engstruct.2004.05.018
- Lioe, R., Wong, W. (2012), The Sands Hotel and Sands SkyPark, The Arup Journal, 1, 17-20.
- Majumder, M., Gangopadhyay, T. K., Chakraborty, A. K., Dasgupta, K., Bhattacharty, D. K. (2008), Fibre Bragg gratings in structural health monitoring-Present Status and applications, Sensors and Actuators A: Physical, 147(1), 150-164. https://doi.org/10.1016/j.sna.2008.04.008
- Park, H. S., Jung, H. S., Kwon, Y. H., Seo, J. H. (2006), Analytical models for assessment of the safety of steel beams based on average strains from long gage optic sensors, Sensors and Actuators A: Physical, 125, 109-113. https://doi.org/10.1016/j.sna.2005.04.038
- Park, H. S., Jung, S. M., Lee, H. M., Kwon, Y. H., Seo, J. H. (2007), Analytical models for assessment of the safety of multi-span steel beams based on average strains from long gage optic sensors, Sensors and Actuators A: Physical, 137, 6-12. https://doi.org/10.1016/j.sna.2007.01.015
- Park, H. S., Park, K. T., Lee, K. W. (2001), An Experimental Study on Characteristic Analysis of Deflection Response of RC Structures Using Measured Strain, Journal of the Korea Institute for Structural Maintenance and Inspection, 5(3), 173-180 (in Korean).
- Park, H. S., Shin, Y., Choi, S. W., and Kim, Y. (2013), An Integrated Structural Health Monitoring System for the Local/Global Response of a Large-Scale Irregular Building under Construction, Sensors, 13, 9085-9103. https://doi.org/10.3390/s130709085
- Tam, H., Au, H. Y., Chung, K. M., Liao, W. Y., Chung, W. H., Liu, S. Y., Lai, S. Y., Lai, C. C., Ni, Y. Q., Csipkes, A. (2011), Distribution Optical Sensor System on the 610-m Guangzhou New TV Tower, Optical Fiber Communication Conference, Los Angeles.
- Yu, F., Gupta, N. (2005), An efficient model for improving performance of vibrating-wire instruments, Measurement: Journal of the International Measurement Confederation, 37(3), 278-283. https://doi.org/10.1016/j.measurement.2004.12.003
Cited by
- A Strain based Load Identification for the Safety Monitoring of the Steel Structure vol.18, pp.2, 2014, https://doi.org/10.11112/jksmi.2014.18.2.064