Acknowledgement
Supported by : Ho Chi Minh City University
References
- Ayres, J.W., Lalande, F., Chaudhry, Z. and Rogers, C.A. (1998), "Qualitative impedance-based health monitoring of civil infrastructures", Smart Mater. Struct., 7(5), 599-605. https://doi.org/10.1088/0964-1726/7/5/004
- Bhalla, S. and Soh, C.K. (2003), "Structural impedance based damage diagnosis by piezo-transducers", Earthq. Eng. Struct. D., 32(12), 1897-1916. https://doi.org/10.1002/eqe.307
- Chaudhry, Z., Lalande, F., Ganino, A. and Rogers, C.A. (1996), Monitoring the integrity of composite patch structural repair via piezoelectric actuators/sensors, AIAA-1996-1074-CP.
- Doebling, S.W., Farrar, C.R. and Prime, M.B. (1998), "A summary review of vibration-based damage identification methods", Shock Vib. Dig., 30( 2), 91-105. https://doi.org/10.1177/058310249803000201
- Farrar, C.R. (2001), Historical overview of structural health monitoring, Lecture Notes on Structural Health Monitoring Using Statistical Pattern Recognition, Los Alamos Dynamics, Los Alamos, NM.
- Giurgiutiu, V. and Zagrai, A. (2005), "Damage detection in thin plates and aerospace structures with the electro-mechanical impedance method", Struct. Health Monit,, 4(2), 0099-20. https://doi.org/10.1177/1475921705049752
- Giurgiutiu, V. and Zagrai, A.N. (2002), "Embedded self-sensing piezoelectric active sensors for online structural identification", J. Vib. Acoust., 124(1), 116-125. https://doi.org/10.1115/1.1421056
- Ho, D.D. (2012), Multi-scale smart sensing of vibration and impedance for structural health monitoring of cable-stayed bridge, Ph.D. Dissertation, Pukyong National University, Korea.
- Kim, J.T., Huynh, T.C. and Lee, S.Y. (2014), "Wireless structural health monitoring of stay cables under two consecutive typhoons", Struct.Monit. Maint., 1(1), 47-67.
- Kim, J.T., Park, J.H., Hong, D.S. and Park, W.S. (2010), "Hybrid health monitoring of prestressed concrete girder bridges by sequential vibration impedance approaches", Eng. Struct., 32(1), 115-128. https://doi.org/10.1016/j.engstruct.2009.08.021
- Li, H.N., Yi, T.H., Ren, L., Li, D.S. and Huo, L.S. (2014), "Reviews on innovations and applications in structural health monitoring for infrastructures", Structural Monit. Maint., 1(1), 1-45. https://doi.org/10.12989/smm.2014.1.1.001
- Liang, C., Sun, F.P. and Rogers, C.A. (1994), "Coupled electro-mechanical analysis of adaptive material systems-determination of the actuator power consumption and system energy transfer", J. Intel. Mat. Syst. Str., 5(1), 12-20. https://doi.org/10.1177/1045389X9400500102
- Liu, X. and Jiang, Z. (2009), "Design of a PZT patch for measuring longitudinal mode impedance in the assessment of truss structure damage", Smart Mater. Struct., 18(12), ID125017.
- Min, J., Park, S., Yun, C.B. and Song, B. (2010), "Development of a low-cost multifunctional wireless impedance sensor node", Smart Struct. Syst., 6(5-6), 689-709. https://doi.org/10.12989/sss.2010.6.5_6.689
- Nassar, S.A., Barber, G.C. and Zuo, D. (2005), "Bearing friction torque in bolted joints", Tribilogy Transactions, 48, 69-75. https://doi.org/10.1080/05698190590899967
- Park, G., Sohn, H., Farrar, C. and Inman, D. (2003), "Overview of piezoelectric impedance-based health monitoring and path forward", Shock Vib. Dig., 35(6), 451-463. https://doi.org/10.1177/05831024030356001
- Park, S., Ahmad, S., Yun, C.B. and Roh, Y. (2006), "Multiple crack detection of concrete structures using impedance-based structural health monitoring techniques", Exp. Mech., 46(5), 609-618. https://doi.org/10.1007/s11340-006-8734-0
- Park, S., Yun, C.B., Roh, Y. and Lee, J. (2005), "Health monitoring of steel structures using impedance of thickness modes at PZT patches", Smart Struct. Syst., 1(4), 339-353. https://doi.org/10.12989/sss.2005.1.4.339
- Pohl, J., Herold, S., Mook, G. and Michel, F. (2001), "Damage detection in smart CFRP composites using impedance spectroscopy", Smart Mater. Struct., 10(4), 834-842. https://doi.org/10.1088/0964-1726/10/4/328
- Raju, V. (1998), Implementing impedance-based health monitoring technique, Master Thesis, Virginia Polytechnic Institute and State University, Blacksburg, VA.
- Soh, C., Tseng, K., Bhalla, S. and Gupta, A. (2000), "Performance of smart piezoceramic patches in health monitoring of a RC bridges", Smart Mater. Struct., 9(4), 533-542. https://doi.org/10.1088/0964-1726/9/4/317
- Sun, F.P., Chaudhry, Z., Liang, C. and Rogers, C.A. (1995), "Truss structure integrity identification using PZT sensor-actuator", J. Intel. Mat. Syst. Str., 6(1), 134-139. https://doi.org/10.1177/1045389X9500600117
- Zagrai, A.N. and Giurgiutiu, V. (2001), "Electro-mechanical impedance method for crack detection in thin plates", J. Intel. Mat. Syst. Str., 12(10), 709-718. https://doi.org/10.1177/104538901320560355
Cited by
- Temperature effect on wireless impedance monitoring in tendon anchorage of prestressed concrete girder vol.15, pp.4, 2015, https://doi.org/10.12989/sss.2015.15.4.1159
- Load monitoring of pin-connected structures using piezoelectric impedance measurement vol.25, pp.10, 2016, https://doi.org/10.1088/0964-1726/25/10/105011
- Sensing Region Characteristics of Smart Piezoelectric Interface for Damage Monitoring in Plate-Like Structures vol.19, pp.6, 2019, https://doi.org/10.3390/s19061377