Effectiveness of R/C jacketing of substandard R/C columns with short lap splices

  • Kalogeropoulos, George I. (Department of Civil Engineering, Aristotle University of Thessaloniki) ;
  • Tsonos, Alexander G. (Department of Civil Engineering, Aristotle University of Thessaloniki)
  • Received : 2014.05.30
  • Accepted : 2014.08.20
  • Published : 2014.09.25

Abstract

The effectiveness of a retrofitting method for concrete columns with particular weaknesses is experimentally evaluated and presented in this paper. Structural deficiencies namely the inadequacy of transverse reinforcement and short length of lap splices are very common in columns found in structures built prior to the 1960s and 1970s. Recent earthquakes worldwide have caused severe damages and collapses of these structures. Nevertheless, the importance of improving the load transfer capacity between the deficiently lap-spliced bars is usually underestimated during the strengthening procedures applied in old buildings, though critical for the safety of the residents' lives. Thus, the seismic performance of the enhanced columns is frequently overestimated. The retrofitting approach presented herein involves reinforced concrete jacketing of the column sub-assemblages and welding of the lap-spliced bars to prevent the splice failure and conform to the provisions of modern design Codes. The cyclic lateral loading response of poorly confined original column specimens with insufficient lap splices and the seismic behavior of the retrofitted columns are compared. Test results clearly demonstrate that the retrofitting procedure followed is an effective way of significantly improving the seismic performance of substandard columns found in old buildings.

Keywords

References

  1. Chai, H.Y., Priestley., M.J.N. and Seible, F. (1991), "Seismic retrofit of circular bridge columns for enhanced flexural performance", ACI Struct. J., 88(5), 572-584.
  2. Cho, J.Y. and Pincheira, A.J. (2006), "Inelastic analysis of reinforced concrete columns with short lap splices subjected to reversed cyclic loads", ACI Struct. J., 103(2), 280-290.
  3. Choi, E., Chung, Y.S., Park, K. and Jeon, J.S. (2013), "Effect of steel wrapping jackets on the bond strength of concrete and the lateral performance of circular rc columns", Eng. Struct., 48, 43-54. https://doi.org/10.1016/j.engstruct.2012.08.026
  4. Ehsani, M.R. and Wight, J.K. (1985), "Exterior reinforced concrete beam-to-column connections subjected to earthquake - type loading", ACI J., Proceedings, 82(4), 492-499.
  5. ElGawady, M., Endeshaw, M., McLean, D. and Sack, R. (2010), "Retrofitting of rectangular columns with deficient lap splices", J. Compos. Constr., 14(1), 22-35. https://doi.org/10.1061/(ASCE)CC.1943-5614.0000047
  6. Engideniz, M., Kahn, L.F. and Zureick, A.H. (1993), "Repair and strengthening of reinforced concrete beam-column joints", State of the Art, ACI Struct. J., 90(3), 249-261.
  7. EN 1998-1 (2004), Eurocode 2: Design of Concrete Structures-Part 1-1: General rules and rules for Buildings.
  8. EN 1998-1 (2004), Eurocode 8: Design of Structures for Earthquake Resistance -Part 1: General Rules, Seismic Actions and Rules for Buildings.
  9. Gomes, A.M. and Appleton, J. (1998), "Repair and strengthening of reinforced concrete elements under cyclic loading", Proceedings of the 11th European Conference of Earthquake Engineering, Paris, France.
  10. Harajli, M.H. (2009), "Bond strengthening of lap-spliced reinforcement using external FRP jackets: An effective technique for seismic retrofit of rectangular or circular RC columns", Constr. Build. Mater., 23(3), 1265-1278. https://doi.org/10.1016/j.conbuildmat.2008.07.028
  11. Julio, N.B.S.E. and Branco, A.B.F. (2008), "Reinforced concrete jacketing-interface influence on cyclic loading response", ACI Struct. J., 105(4), 471-477.
  12. Karayannis, G.C., Chalioris, E.C. and Sirkelis, M.G. (2008), "Local retrofit of exterior RC beam-column joints using thin rc jackets - An experimental study", Earthq. Eng. Struct. D., 37(5), 727-746. https://doi.org/10.1002/eqe.783
  13. Karayannis, G.C. and Sirkelis, M.G. (2008), "Strengthening and rehabilitation of rc beam-column joints using carbon-FRP jacketing and epoxy resin injection", Earthq. Eng. Struct. D., 37(5), 769-790. https://doi.org/10.1002/eqe.785
  14. Lynn, C.A., Moehle, P. J., Mahin, A.S. and Holmes, T.W. (1996), "Seismic evaluation of existing reinforced concrete building columns", Earthq. Spectra, 12(4), 715-739. https://doi.org/10.1193/1.1585907
  15. Melek, M. and Wallace, W.J. (2004), "Cyclic behavior of columns with short lap splices", ACI Struct. J., 101(6), 802-811.
  16. C.D.C.S. (2000), New Greek Code for the Design of Reinforced Concrete Structures, Athens.
  17. C.S.R.T.C (2008), New Code of Steel Reinforcement Technology for Concrete, Athens.
  18. Priestley, M.J.N., Seible, F. and Calvi, G.M. (1996), Seismic design and retrofit of bridges, John Willey and Sons, New York, NY, USA.
  19. Rodriguez, M. and Park, R. (1994), "Seismic load tests on reinforced concrete columns strengthened by jacketing", ACI Struct. J., 91(2), 150-159.
  20. Thai, D.X. and Pimanmas, A. (2011), "Response of lap splice of reinforcing bars confined by FRP wrapping: modeling approach", Struct. Eng. Mech., 37(1), 95-110. https://doi.org/10.12989/sem.2011.37.1.095
  21. Tsonos, G.A. (2001), "Seismic retrofit of r/c beam-to-column joints using local three-sided jackets", European Earthq. Eng., 1, 48-64.
  22. Tsonos, G.A. (2008), "Effectiveness of CFRP-jackets and r/c-jackets in post-earthquake and pre-earthquake retrofitting of beam-column subassemblages", Eng. Struct., 30(3), 777-793. https://doi.org/10.1016/j.engstruct.2007.05.008
  23. Tsonos, G.A. (2002), "Seismic repair of exterior r/c beam-to-column joints using two-sided and three-sided jackets", Struct. Eng. Mech., 13(1), 17-34. https://doi.org/10.12989/sem.2002.13.1.017
  24. Tsonos, G.A. (2010), "Performance enhancement of r/c building columns through shotcrete jacketing", Eng. Struct., 32(3),726-740. https://doi.org/10.1016/j.engstruct.2009.12.001
  25. Valluvan, R., Kreger, E.M. and Jirsa O.J. (1993), "Strengthening of column splices for seismic retrofit of nonductile reinforced concrete frames", ACI Struct. J., 90(4), 432-440.

Cited by

  1. Pre-earthquake and post-earthquake retrofitting of poorly detailed exterior RC beam-to-column joints vol.109, 2016, https://doi.org/10.1016/j.engstruct.2015.11.009
  2. Equivalent bilinear elastic single degree of freedom system of multi-degree of freedom structure with negative stiffness vol.365, 2016, https://doi.org/10.1016/j.jsv.2015.11.005
  3. Repair of Heavily Damaged RC Beams Failing in Shear Using U-Shaped Mortar Jackets vol.9, pp.6, 2019, https://doi.org/10.3390/buildings9060146
  4. Strengthening of deficient RC joints with diagonally placed external C-FRP ropes vol.20, pp.1, 2014, https://doi.org/10.12989/eas.2021.20.1.123
  5. Seismic Performance of RC Beam-Column Joints Designed According to Older and Modern Codes: An Attempt to Reduce Conventional Reinforcement Using Steel Fiber Reinforced Concrete vol.9, pp.7, 2014, https://doi.org/10.3390/fib9070045