DOI QR코드

DOI QR Code

Induced Prisms of Wearing Glasses Measured by Photographing

사진촬영으로 측정한 착용안경의 유발프리즘

  • Received : 2014.11.04
  • Accepted : 2014.12.05
  • Published : 2014.12.31

Abstract

Purpose: The matching of the optical center and the pupil center was measured by photographs in wearing glasses. In this study, the influences of the induced prism by the mismatching are studied. Methods: 74 subjects (148 eyes) who were spectacles wearer were participated in this study. The mean age was $29.19{\pm}12.22$ years (range 19-55 years). The facial photographs of subjects were taken while wearing spectacles. The matching of the corneal reflected image and optical center of the spectacle lens in the horizontal deviations, and the vertical deviations were measured by the observation of the photo image. The prisms induced in accordance with various frame type were calculated from the mismatching deviations. Results: The binocular horizontal deviations were $1.55{\pm}1.70mm$ for the metal frame, $1.71{\pm}2.21mm$ for the clings type plastic frame, and $1.15{\pm}1.38mm$ for the plastic frame. In the horizontal direction induced prism, the ratio over the tolerance was 23%. The ratio were the 17.6% at the BI prism, and 5.4% at the BO prism. The binocular vertical deviation comparisons were $3.93{\pm}1.91mm$ for the metal frame, $5.79{\pm}1.93mm$ for the clings type plastic frame, and 1$6.01{\pm}2.94mm$ for the plastic frame. In the vertical direction induced prism, the ratio over the tolerance was 44.6%. Based on the refraction power, the ratio were 12.2% at -0.25${\leq}-3.00$, and 32.4% at -3.00${\leq}-12.00D$. Conclusions: The induced prisms in the horizontal direction were much in the BI prism. The binocular vertical deviations of the glasses.

목적: 착용안경의 광학중심점과 동공중심의 일치여부를 사진촬영방법으로 확인하였으며, 불일치에 의해 유발되는 프리즘 영향을 연구하였다. 방법: 안경착용자 74명(148안), 평균나이 $29.19{\pm}12.22$세(19~55세)를 대상으로 안경을 착용한 상태에서 카메라 플래시를 터트리면서 안면사진을 촬영하였다. 촬영된 사진으로 각막반사상과 안경렌즈 광학중심점의 일치, 수평 및 수직오차를 측정하였으며, 불일치 편차로부터 안경테에 따라 유발되는 프리즘을 산출하였다. 결과: 양안수평오차는 금속테가 $1.55{\pm}1.70mm$, clings type 플라스틱테가 $1.71{\pm}2.21mm$, 플라스틱테가 $1.15{\pm}1.38mm$이었다. 수평방향의 유발된 프리즘이 허용오차를 벗어난 비율이 23.0%였으며, BI 프리즘 17.6%, BO 프리즘 5.4%이었다. 양안수직오차는 금속테가 $3.93{\pm}1.91mm$, clings type 플라스틱테가 $5.79{\pm}1.93mm$, 플라스틱테가 $6.01{\pm}2.94mm$이었다. 수직방향의 유발된 프리즘이 허용오차를 벗어난 비율은 44.6%였으며, 안경렌즈의 굴절력을 기준으로 -0.25${\leq}-3.00$에서 12.2%, -3.00${\leq}-12.00$에서 32.4%가 허용오차범위를 벗어났다. 결론: 수평방향에서 유도된 프리즘은 BI 프리즘이 많았다. 양안수직오차는 플라스틱테의 안경이 금속테의 안경보다 크게 나타났으며, 교정 굴절력이 높은 안경일수록 유발된 프리즘이 더 컸다. 사진촬영 방법으로 동공의 위치와 광학중심점을 동시에 측정할 수 있으며, 착용안경에서 유발되는 프리즘을 직접 평가할 수 있었다.

Keywords

References

  1. Clifford WB, Irvin MB. System for Ophthalmic Dispensing, 3rd Ed. London: Butterworth-Heinemann, 2007;25.
  2. Kim HD. Ophthalmic Dispensing, 1st Ed. Seoul: Shinkwangpublisher, 2008;125-126.
  3. Sung PJ. Optometry, 8rd Ed. Seoul: Daihaksurim, 2013; 187-188.
  4. Kim HJ, Park SA, Baek JS, Park JH, Lee EH. Measurement of Horizontal and Vertical Prism Diopter According to Difference between the Optical Center and Pupil Center. J Korean Ophthalmic Opt Soc. 2011;16(1):1-5.
  5. Park WJ, Kim SW, Hwang HY, Yu DS, Son JS. Induced Prism by the Categories of Spectacle Frames. J Korean Ophthalmic Opt Soc. 2012;17(3):311-319.
  6. Osuobeni EP, al-Fahdi M. Differences between anatomical and physiological interpupillary distance. J American Optometric Association. 1994;65(4):265-271.
  7. Sung PJ. Optometry, 8rd Ed. Seoul: Daihaksurim, 2013; 120-121.
  8. Sung PJ. Optometric dispensing, 3rd Ed. Seoul: Daihaksurim, 2010;386-388.
  9. Sung PJ. Optometric dispensing, 3rd Ed. Seoul: Daihaksurim, 2010;73.
  10. Sung DY, Lee WJ, Kang SS. A Study for the Horizontal Induced Phoria in Spectacles Wearers. J Korean Ophthalmic Opt Soc. 1996;1(2):85-91.
  11. Lee YD, Lee YI, Bae SR. Prism Diopter for Unconformity between the Optical Center and the Pupil Center. J Korean Ophthalmic Opt Soc. 2003;44(8):1859-1864.
  12. Kim JH. The Factcrs Influencing The Quantity of Phoria. J Korean Ophthalmic Opt Soc. 2004;9(2):361-370.
  13. Kim HD, Park EK, Kim KH. Clinical Evaluation between The Optical Center of Sprectacles and Pupillary Center. J Korean Ophthalmic Opt Soc. 2003;8(2):19-24.
  14. Jin YH, Moon NJ, Sung PJ. Refractive examinations and prescriptions, 3rd Ed. Seoul: Naewaehaksool, 2009;166.