DOI QR코드

DOI QR Code

DEVELOPMENT OF LEAD SLOWING DOWN SPECTROMETER FOR ISOTOPIC FISSILE ASSAY

  • 투고 : 2014.06.12
  • 심사 : 2014.09.12
  • 발행 : 2014.12.25

초록

A lead slowing down spectrometer (LSDS) is under development for analysis of isotopic fissile material contents in pyro-processed material, or spent fuel. Many current commercial fissile assay technologies have a limitation in accurate and direct assay of fissile content. However, LSDS is very sensitive in distinguishing fissile fission signals from each isotope. A neutron spectrum analysis was conducted in the spectrometer and the energy resolution was investigated from 0.1eV to 100keV. The spectrum was well shaped in the slowing down energy. The resolution was enough to obtain each fissile from 0.2eV to 1keV. The detector existence in the lead will disturb the source neutron spectrum. It causes a change in resolution and peak amplitude. The intense source neutron production was designed for ~E12 n's/sec to overcome spent fuel background. The detection sensitivity of U238 and Th232 fission chamber was investigated. The first and second layer detectors increase detection efficiency. Thorium also has a threshold property to detect the fast fission neutrons from fissile fission. However, the detection of Th232 is about 76% of that of U238. A linear detection model was set up over the slowing down neutron energy to obtain each fissile material content. The isotopic fissile assay using LSDS is applicable for the optimum design of spent fuel storage to maximize burnup credit and quality assurance of the recycled nuclear material for safety and economics. LSDS technology will contribute to the transparency and credibility of pyro-process using spent fuel, as internationally demanded.

키워드

참고문헌

  1. Y.D. Lee, et. al., "Design of LSDS for Isotopic Fissile Assay in Spent Fuel," Nuclear Energy and Technology, Vol. 45, No. 7, 2013. https://doi.org/10.5516/NET.06.2013.044
  2. YongDeok Lee, et al., "Development of LSDS spectrometer for nuclear fissile assay", Global2009, September 7-10, 2009
  3. YongDeok Lee, et al., "Design of Lead Slowing Down Spectrometer for Spent Fuel Fissile Assay", 52nd INMM, July 17-21, 2011.
  4. M. E. Abhold et al., Survey of Seven Measurement Techniques for Quantifying the Fissile Content of Spent Fuel, LA-UR-07-3336, LANL, 2007.
  5. D. Rochman, R.C. Haight, J.M. O'Donnel, A. Michaudon, S.A. Wender, D.J. Vieira, E.M. Bond, T.A. Bredeweg, A. Kronenberg, J.B. Wilhelmy, T. Ethvignot, T. Granier, M. Petit, and Y. Danon, "Characteristics of a Lead Slowing-Down Spectrometer Coupled to the LANSCE Accelerator," Nuclear Instruments and Methods in Physical Research A, 550, 397 (2005). https://doi.org/10.1016/j.nima.2005.04.075
  6. A. Gavron, et al., "Analysis of Spent Fuel Assay with a Lead Slowing Down Spectrometer," Global 2009, Paris, Sept. 6-11, 2009.
  7. MCNP, D. B. Pelowitz, ed., MCNP: A General Monte Carlo Code for Neutron and Photon Transport, LA-CP-05-0369, Los Alamos National Laboratory, 2005.
  8. P. C. Durst et al., Advanced Safeguards Approaches for New TRU Fuel Fabrication Facilities, PNNL-17151, DE-AC05-76RL01830, Nov. 2007.
  9. Horia R. Radulescu et al., Pulsed Neutron Generator Facility for Slowing Down Time Spectrometry, ANRCP-1999-29, Oct. 1999.
  10. H.R. Radulescu, N.M. Abdurrahman, A.I. Hawari, and B.W. Wehring, Pulsed Neutron Generator Facility for Slowing Down Time Spectrometry, ANRCP-1999-29, October 1999.
  11. N. Baltateanu, M. Jurba, V. Calian, G. Stoenescu, "Optimal Fast Neutron Sources Using Linear Electron Accelerators," Proceedings of EPAC 2000, pp.2591-2593,Vienna, Austria (2000).
  12. J.D. Kim, et. al, Optimization of operation parameters of 80-keV electron gun, NET, Vol. 47, No. 3, 2014. https://doi.org/10.5516/NET.06.2013.092
  13. A. G. Croff, ORIGEN2 Isotope generation and depletion code matrix exponential method, Oak Ridge National Laboratory, 1985.