Abstract

The weight calculation in an iterative algorithm is the most computationally costly task in computed tomography image reconstruction. In this letter, a fast algorithm to speed up the weight calculation is proposed. The classic square pixel rotation approximate calculation method for computing the weights in the iterative algorithm is first analyzed and then improved by replacing the square pixel model with a circular pixel model and the square rotation approximation with a segmentation method of a circular area. Software simulation and hardware implementation results show that our proposed scheme can not only improve the definition of the reconstructed image but also accelerate the reconstruction.

Keywords

References

  1. L.A. Shepp and B.F. Logan, "The Fourier Reconstruction of a Head Section," IEEE Trans. Nuc. Sci., 1974, pp. 21-43.
  2. Q.H. Zhang, H.N. Lu, and M. Yang, "Fast Implementation of Fieldkamp Reconstruction Algorithm in Cone-Beam Industrial CT," Comput. Eng. Design, vol. 27, no. 6, 2006, pp. 931-933.
  3. E.T. Quinto, "Singularities of the X-ray Transform and Limited Data Tomography in $R^2$ and $R^3$," SIAM J. Math. Anal., 1993, pp. 1215-1225.
  4. G.A. Kastis et al., "Evaluation of a Spline Reconstruction Technique: Comparison with FBP, MLEM and OSEM," IEEE Nuc. Sci. Symp. Conf. Record, 2010, pp. 3282-3287.
  5. N. Subramanian, "A C-to-FPGA Solution for Accelerating Tomographic Reconstruction," University of Washington, 2009.
  6. M. Leeser et al., "Parallel-Beam Backprojection: An FPGA Implementation Optimized for Medical Imaging," Proc. 10th Int. Symp. FPGA, 2002, pp. 217-226.
  7. B. Heigl and M. Kowarschik, "High-Speed Reconstruction for C-Arm Computed Tomography," Proc. 9th Int. Meeting Fully 3D Image Reconstr. Radiol. Nuc. Med., Lindau: HPIR, 2008, pp. 25-28.
  8. P. Basu and M. Manjunatha, "VHDL Modeling and Simulation of Parallel-Beam Filtered Backprojection for CT Image Reconstruction," Proc. IEEE Int. Conf. Multimedia, Signal Process., Commun. Technol., 2009, pp. 213-216.

Cited by

  1. Three-Dimensional Computer-Aided Detection of Microcalcification Clusters in Digital Breast Tomosynthesis vol.2016, pp.None, 2013, https://doi.org/10.1155/2016/8651573