Abstract
The relation between performance maintenance conditions and those cost efficiency was studied to choose an optimum operating condition in the seawater desalination pretreatment system. A hollow fiber microfiltration module, which was developed with domestic technology, was tested with the various operating conditions such as chemically enhanced backwash cycles and design dosages of a cleaning chemical. Transmembrane pressure was measured to investigate membrane fouling status and cleaning degree. In addition, economic analysis was performed to compare water production costs by the operation condition. As a result, The operation mode III, chemically enhanced backwash at once a day with 100 mg/L of sodium hypochlorite (NaOCl) was selected. The concurrent evaluation between membrane filtration performance and its economic analysis will be suitable to choose an efficient optimum condition.
본 연구는 해수담수화 전처리 기술로서 개발된 가압식 정밀여과(microfiltration: MF) 중공사막 모듈(막 면적 $35m^2$)의 성능평가를 목적으로 $1,000m^3/day$ 규모 해수담수화 파일럿플랜트를 대상으로 하였다. 약 3개월 동안 용존공기부상법으로 처리한 원수를 공급하여 $1.5m^3/m^2{\cdot}day$ 정유량 조건에서 여과주기, 유지 세정(chemically enhanced backwash: CEB) 농도와 세정 주기 변화 등에 따른 여과성능과 비용을 분석하였다. MF 막 성능 유지를 위한 유지 세정 시 약품 농도에 의한 영향보다는 반복 세정(4회/일)이 효과적이었으나, 경제적 측면에서는 회수율 제고를 위한 단일 세정 방식이 적절한 것으로 나타났다. 막간차압 및 비용분석을 통해 4가지 운전방식 중 1일 1회 NaOCl 100 mg/L 세정 방식을 최적 운전조건으로 도출하였다. MF 전처리 공정의 유지관리 조건 도출 시에는 성능 평가와 함께, 운전방식에 따른 경제성을 함께 고려하는 것이 적절할 것으로 판단된다.