참고문헌
- Alleyne, D.N., Pavlakovic, B., Lowe, M.J.S. and Cawley, P. (2001), "Rapid long-range inspection of chemical plant pipework using guided waves", Rev. Prog. Quant. Nondestr. Eval., 20, 180-187.
- Bossy, E., Talmant, M., Defontaine, M., Patat, F. and Laugier, P. (2004), "Bidirectional axial transmission can improve accuracy and precision of ultrasonic velocity measurement in cortical bone: a validation on test materials", IEEE Trans. Ultrason. Ferroelectr. Freq. Contral, 51(1), 71-79. https://doi.org/10.1109/TUFFC.2004.1268469
- Bossy, E., Talmant, M. and Laugier, P. (2002), "Effect of bone cortical thickness on velocity measurements using ultrasonic axial transmission: a 2D simulation study", J. Acoust. Soc. Am., 112(1), 297-307. https://doi.org/10.1121/1.1480836
- Cau, F., Fanni, A., Montisci, A., Testoni, P. and Usai, M. (2006), "A signal-processing tool for nondestructive testing of inaccessible pipes", Eng. Appl. Artif. Intel., 19(7), 753-760. https://doi.org/10.1016/j.engappai.2006.05.005
- Cawley, P., Lowe, M.J.S., Alleyne, D.N., Pavlakovic, B. and Wilcox, P. (2003), "Practical long range guided wave testing: applications to pipes and rail", Mater. Eval., 61(1), 66-74.
- Cheeke, J.D.N., Li, X. and Wang, Z. (1998), "Observation of flexural Lamb waves (A0 mode) on waterfilled cylindrical shells", J. Acoust. Soc. Am., 104(6), 3678-3680. https://doi.org/10.1121/1.423951
- Chen, J., Cheng, L., Su, Z. and Qin, L. (2013a), "Modeling elastic waves in coupled media: estimate of soft tissue influence and application to quantitative ultrasound", Ultrasonics, 53(2), 350-362. https://doi.org/10.1016/j.ultras.2012.06.018
- Chen, J. and Su, Z. (2013b), "On ultrasound waves in bones with coupled soft tissues: a mechanism study and in vitro calibration", Ultrasonics. (in press)
- Chen, J., Su, Z. and Cheng, L. (2010a), "Identification of corrosion damage in submerged structures using anti-symmetric Lamb wave mode", Proceedings of the 5th European Workshop on Structural Health Monitoring, Naples, Italy, Jul.
- Chen, J., Su, Z. and Cheng, L. (2012b), "The medium coupling effect on propagation of guided waves in engineering structures and human bone phantoms", Coupled Systems Mechanics, 1(4), 297-309. https://doi.org/10.12989/csm.2012.1.4.297
- Chen, J., Su, Z., Cheng, L. and Qin, L. (2010b), "Influence of soft tissues on ultrasonic Lamb waves in synthesised soft tissue-bone phantoms", IFMBE Proceedings, 31(6), 1315-1318. https://doi.org/10.1007/978-3-642-14515-5_335
- Dong, X.N. and Guo, X.E. (2004), "The dependence of transversely isotropic elasticity of human femoral cortical bone on porosity", J. Biomech., 37(8), 1281-1287. https://doi.org/10.1016/j.jbiomech.2003.12.011
- Laugier, P. and Haiat , G. (2011), Bone Quantitative Ultrasound, Springer, New York.
- Le, L.H., Gu, Y.J., Li, Y.P. and Zhang, C. (2010), "Probing long bones with ultrasonic body waves", Appl. Phys. Lett., 96(11), 114102. https://doi.org/10.1063/1.3300474
- Lee, K.I. and Yoon, S.W. (2004), "Feasibility of bone assessment with leaky Lamb waves in bone phantoms and a bovine tibia", J. Acoust. Soc. Am., 115(6), 3210-3217. https://doi.org/10.1121/1.1707086
- Lefebvre, F., Deblock, Y., Campistron, P., Ahite, D. and Fabre, J.J. (2002), "Development of a new ultrasonic technique for bone and biomaterials in vitro characterization", J. Biomed. Mater. Res., 63(4), 441-446. https://doi.org/10.1002/jbm.10261
- Leonard, K.R. and Hinders, M.K. (2003), "Guided wave helical ultrasonic tomography of pipes", J. Acoust. Soc. Am., 114(2), 767-774. https://doi.org/10.1121/1.1593068
- Li, F.C., Su, Z.Q., Ye, L. and Meng, G. (2006), "A correlation filtering-based matching pursuit (CF-MP) for damage identification using Lamb waves", Smart Mater. Struct., 15(6), 1585-1594. https://doi.org/10.1088/0964-1726/15/6/010
- Li, J. and Rose, J.L. (2006), "Natural beam focusing of non-axisymmetric guided waves in large-diameter pipes", Ultrasonics, 44(1), 35-45. https://doi.org/10.1016/j.ultras.2005.07.002
- Lowe, M.J.S., Alleyne, D.N. and Cawley, P. (1998), "Defect detection in pipes using guided waves", Ultrasonics, 36(1-5), 147-154. https://doi.org/10.1016/S0041-624X(97)00038-3
- Minonzio, J.G., Foiret, J., Talmant, M. and Laugier, P. (2011), "Impact of attenuation on guided mode wavenumber measurement in axial transmission on bone mimicking plates", J. Acoust. Soc. Am., 130(6), 3574-3582. https://doi.org/10.1121/1.3652884
- Minonzio, J.G., Talmant, M. and Laugier, P. (2010), "Guided wave phase velocity measurement using multiemitter and multi-receiver arrays in the axial transmission configuration", J. Acoust. Soc. Am., 127(5), 2913-2919. https://doi.org/10.1121/1.3377085
- Moilanen, P., Nicholson, P.H.F., Kilappa, V., Cheng, S. and Timonen, J. (2006), "Measuring guided waves in long bones: Modeling and experiments in free and immersed plates", Ultrasound. Med. Biol., 32(5), 709-719. https://doi.org/10.1016/j.ultrasmedbio.2006.02.1402
- Moilanen, P., Nicholson, P.H.F., Kilappa, V., Cheng, S.L. and Timonen, J. (2007a), "Assessment of the cortical bone thickness using ultrasonic guided waves: Modelling and in vitro study", Ultrasound. Med. Biol., 33(2), 254-262. https://doi.org/10.1016/j.ultrasmedbio.2006.07.038
- Moilanen, P., Talmant, M., Nicholson, P.H.F., Cheng, S.L., Timonen, J. and Laugier, P. (2007b), "Ultrasonically determined thickness of long cortical bones: Three-dimensional simulations of in vitro experiments", J. Acoust. Soc. Am., 122(4), 2439-2445. https://doi.org/10.1121/1.2769619
- Muller, M., Moilanen, P., Bossy, E., Nicholson, P., Kilappa, V., Timonen, J., Talmant, M., Cheng, S. and Laugier, P. (2005), "Comparison of three ultrasonic axial transmission methods for bone assessment", Ultrasound. Med. Biol., 31(5), 633-642. https://doi.org/10.1016/j.ultrasmedbio.2005.02.001
- Nicholson, P.H.F., Moilanen, P., Karkkainen, T., Timonen, J. and Cheng, S. (2002), "Guided ultrasonic waves in long bones: Modelling, experiment and in vivo application", Physiol. Meas., 23(4), 755-768. https://doi.org/10.1088/0967-3334/23/4/313
- Palmeri, M.L., Sharma, A.C., Bouchard, R.R., Nightingale, R.W. and Nightingale, K.R. (2005), "A finiteelement method model of soft tissue response to impulsive acoustic radiation force", IEEE Trans. Ultrason. Ferroelectr. Freq. Contral, 52(10), 1699-1712. https://doi.org/10.1109/TUFFC.2005.1561624
- Rose, J.L. (1999), Ultrasonic Waves in Solid Media, Cambridge University Press, Cambridge, MA.
- Sasso, M., Talmant, M., Haiat, G., Laugier, P. and Naili, S. (2006), "Development of a multi-dimensional SVD based technique for multi-receivers ultrasound used in bone status characterization", Fourth IEEE Workshop on Sensor Array and Multichannel Processing.
- Shi, L.H. and Ihn, J.B. (2001), "Identification of time-domain refletometry measurement results by wavelet modeling", The 3rd International Workshoip on Strucctural Health Monitoring, Stanford.
- Song, X., Ta, D. and Wang, W. (2011), "Analysis of superimposed ultrasonic guided waves in long bones by the joint approximate diagonalization of eigen-matrices algorithm", Ultrasound. Med. Biol., 37(10), 1704-1713. https://doi.org/10.1016/j.ultrasmedbio.2011.06.028
- Su, Z., Yang, C., Pan, N., Ye, L. and Zhou, L.-M. (2007), "Assessment of delamination in composite beams using shear horizontal (SH) wave mode", Compos. Sci. Technol., 67(2), 244-251. https://doi.org/10.1016/j.compscitech.2006.08.019
- Su, Z. and Ye, L. (2005), "A fast damage locating approach using digital damage fingerprints extracted from Lamb wave signals", Smart Mater. Struct., 14(5), 1047. https://doi.org/10.1088/0964-1726/14/5/043
- Ta, D.A., Huang, K., Wang, W.Q., Wang, Y.Y. and Le, L.H. (2006), "Identification and analysis of multimode guided waves in tibia cortical bone", Ultrasonics, 44(1), e279-e284. https://doi.org/10.1016/j.ultras.2006.06.013
- Ta, D.A., Wang, W.Q., Wang, Y.Y., Le, L.H. and Zhou, Y.Q. (2009), "Measurement of the dispersion and attenuation of cylindrical ultrasonic guided waves in long bone", Ultrasound. Med. Biol., 35(4), 641-652. https://doi.org/10.1016/j.ultrasmedbio.2008.10.007
- Talmant, M., Su, Z., Cheng, L. and Laugier, P. (2012a), "Measurement of guided mode wavenumbers in soft tissue-bone mimicking phantoms using ultrasonic axial transmission", Phys. Med. Biol., 57(10), 3025-3037. https://doi.org/10.1088/0031-9155/57/10/3025
- Tatarinov, A., Sarvazyan, N. and Sarvazyan, A. (2005), "Use of multiple acoustic wave modes for assessment of long bones: Model study", Ultrasonics, 43(8), 672-680. https://doi.org/10.1016/j.ultras.2005.03.004
- Tua, P.S., Quek, S.T. and Wang, Q. (2005), "Detection of cracks in cylindrical pipes and plates using piezoactuated Lamb waves", Smart Mater. Struct., 14(6), 1325-1342. https://doi.org/10.1088/0964-1726/14/6/025
- Velichko, A. and Wilcox, P.D. (2009), "Excitation and scattering of guided waves: relationships between solutions for plates and pipes", J. Acoust. Soc. Am., 125(6), 3623-3631. https://doi.org/10.1121/1.3117441
- Wang, Q. and Yuan, S. (2009), "Wave rebuilding method for the active Lamb wave based structural damage imaging", Chinese Journal of Astronautics, 30(3), 5.
- Xu, K.L., Ta, D.A. and Wang, W.Q. (2010), "Multiridge-based analysis for separating individual modes from multimodal guided wave signals in long bones", IEEE Trans. Ultrason. Ferroelectr. Freq. Contral, 57(11), 2480-2490. https://doi.org/10.1109/TUFFC.2010.1714
- Yu, L., Cheng, L. and Su, Z. (2011), "Correlative sensor array and its applications to identification of damage in plate-like structures", Structural Control and Health Monitoring, 19(8), 650-671.
- Zhao, X., Gao, H., Zhang, G., Ayhan, B., Yan, F., Kwan, C. and Rose, J.L. (2007), "Active health monitoring of an aircraft wing with embedded piezoelectric sensor/actuator network: I. Defect detection, localization and growth monitoring", Smart Mater. Struct., 16(4), 1208-1217. https://doi.org/10.1088/0964-1726/16/4/032