디지털경사계를 사용한 체간재위치오류 검사의 신뢰도 분석

Analysis of Intrarater and Interrater Reliability of Trunk Repositioning Error Test using a Portable Digital Inclinometer

  • 장우남 (연세대학교 세브란스 재활병원 물리치료팀) ;
  • 이경보 (가톨릭대학교 성빈센트병원 물리치료실) ;
  • 염준우 (인제대학교 일산백병원 물리치료실) ;
  • 황병용 (용인대학교 대학원 물리치료학과)
  • Chang, Woo-Nam (Department of Physical Therapy, Severance Rehabilitation Hospital, Yonsei University Health System) ;
  • Lee, Kyoung-Bo (Department of Physical Therapy, St Vincent Hospital, The Catholic University) ;
  • Yeom, Jun-Woo (Department of Physical Therapy, Inje University Ilsan Paik Hospital) ;
  • Hwang, Byong-Yong (Department of Physical Therapy, Graduate School, Yong In University)
  • 투고 : 2013.07.13
  • 심사 : 2013.08.12
  • 발행 : 2013.08.25

초록

Purpose: A cost effective tool for the clinical measurement of trunk reposition sense is clearly needed. This study was to analyze intrarater and interrater Reliability of trunk repositioning error (TRE) test which assesses trunk position sense using a portable digital inclinometer. Methods: Twenty four normal healthy subjects were recruited. TRE was measured using a portable digital inclinometer. A digital inclinometer (Acumar-ACU360; Lafayetter Instrument) with precision to $1^{\circ}$ was placed on skin over the spinous process from first to second thoracic vertebra (T1-T2) and secured with double-sided tape. TRE test during sitting forward and lateral flexion movement was assessed. When they reached a point approximately 50% of full trunk flexion range, the examiner instructed the subjects to stop and told them. This was the target position that they should try to reproduce exactly. Each subject performed six trials. Results: ICC (2,1) for intrarater reliability (with-day and between-day) of TRE test in sagittal and frontal plane of movement was 0.75 and 0.78 (excellent reliability). Interrater reliability was 0.66 in sagittal and 0.64, frontal plane (fair to good reliability). However, there were poor correlations between an average of TRE test in sagittal and frontal plane. Conclusion: TRE test using a portable digital inclinometer demonstrated good to excellent reliability. The device may be a cost effective clinical measurement for trunk reposition sense measurement.

키워드

참고문헌

  1. Brooks VB. How posture and movements are governed. Phys Ther. 1983;63(5):664-73. https://doi.org/10.1093/ptj/63.5.664
  2. Gandevia SC, McCloskey DI, Burke D. Kinaesthetic signals and muscle contraction. Trends Neurosci. 1992;15(2):62-5. https://doi.org/10.1016/0166-2236(92)90028-7
  3. Burgess PR, Wei JY, Clark FJ. Signaling of kinesthetic information by peripheral sensory receptors. Annu Rev Neurosci. 1992;5:171-88.
  4. Newcomer K, Laskowski ER, Yu B et al. Comparing trunk repositioning error in subjects with chronic low back pain and control subjects. Spine. 2000;25(2):245-50. https://doi.org/10.1097/00007632-200001150-00017
  5. Amonoo-Kuofi HS. The number and distribution of muscle spindles in human intrinsic postvertebral muscles. J Anat. 1982;135(3):585-99.
  6. McLain RF, Raiszadeh K. Mechanoreceptor endings in the cervical, thoracic, and lumbar spine. Iowa Orthop J. 1995;15:147-55.
  7. Yu-Min Ko, Mi-Suk Jung, Ji-Won Park. The relationship between strength balance and joint position sense related to ankle joint in healthy women. J Kor Soc Phys Ther. 2011;23(2):23-9.
  8. Wan-Sung Hong, Gi-Won Kim. Reliability of the joint neutral position and measurement methods of the ankle joint complexrange of motion. J Kor Soc Phys Ther. 2011;23(4):45-51. https://doi.org/10.1589/jpts.23.45
  9. Allison G, Fukushima S. Estimating three-dimensional spinal repositioning error: the impact of range, posture, and number of trials. Spine. 2003;28(22):2510-6. https://doi.org/10.1097/01.BRS.0000090821.38624.D5
  10. Swinkels A, Dolan P. Regional assessment of joint position sense in the spine. Spine. 1998;23(5):590-7. https://doi.org/10.1097/00007632-199803010-00012
  11. O'Sullivan PB, Burnett A, Floyd AN et al. Lumbar positioning deficit in a specific low back pain population. Spine. 2003;28(10):1074-9.
  12. Ryerson S, Byl NN, Brown DA et al. Altered trunk position sense and its relation to balance functions in people post-stroke. J Neurol Phys Ther. 2008;32(1):14-20. https://doi.org/10.1097/NPT.0b013e3181660f0c
  13. Yu-Min Ko, Seol Park, Yun-Jin Kim et al. Effects of lumbar position sense on swing chair in healthy adults. J Korean Soc Phys Ther. 2012:24(3):235-9.
  14. Ji-Won Park, Yu-Min Ko, Seol Park. The effect of proprioceptive position sense by fatigue of low back muscles. J Korean Soc Phys Ther. 2012:24(6):414-8.
  15. Petersen CM, Zimmermann CL, Cope S et al. A new measurement method for spine reposition sense. J Neuroeng Rehabil. 2008;5(9):1-11. https://doi.org/10.1186/1743-0003-5-1
  16. Goldberg A, Hernandez M, Alexander N. Trunk repositioning errors are increased in balance-impaired older adults. J Gerontol A Biol Sci Med Sci. 2005;60(10):1310-4. https://doi.org/10.1093/gerona/60.10.1310
  17. Van Blommestein AS, Lewis JS, Morrissey MC et al. Reliability of measuring thoracic kyphosis angle, lumbar lordosis angle and straight leg raise with an inclinometer. Open Orthop J. 2012;4:10-5.
  18. Jin-Hwa Jung, Jae-Ho Yu. The effects of hippotherapy over 8 weeks on trunk proprioception, stability and posture in cerebral palsy patients. J Kor Soc Phys Ther. 2010;22(5):63-70.
  19. Seo JK, Kim SY. The relationship between hip abductor muscle strength and lumbar instability in patients with chronic low back pain. J Korean Soc Phys Ther. 2011;23(4):15-22.
  20. Ebenbichler G, Oddsson L. Sensory-motor control of the lower back: implications for rehabilitation. Med Sci Sports Exerc. 2001;33(11):1889-98. https://doi.org/10.1097/00005768-200111000-00014
  21. Hodges P, Richardson C. Relationship between limb movement speed and associated contraction of the trunk muscles. Ergonomics. 1997;40(11):1220-30. https://doi.org/10.1080/001401397187469
  22. Vincent-Smith B, Gibbons P. Inter-examiner and intraexaminer reliability of the standing flexion test. Man Ther. 1999;4(2):87-93. https://doi.org/10.1054/math.1999.0173
  23. Gill KP, Callaghan MJ. The measurement of lumbar proprioception in individuals with and without low back pain. Spine. 1998;23(3):371-7. https://doi.org/10.1097/00007632-199802010-00017
  24. Loudon JK, Ruhl M, Field E. Ability to reproduce head position after whiplash injury. Spine. 1997;22(8):865-8. https://doi.org/10.1097/00007632-199704150-00008
  25. Parkhurst TM, Burnett CN. Injury and proprioception in the lower back. J Orthop Sports Phys Ther. 1994;19(5):282-95. https://doi.org/10.2519/jospt.1994.19.5.282
  26. Revel M, Deshays AC, Minguet M. Cervicocephalic kinesthetic sensibility in patients with cervical pain. Arch Phys Med Rehabil. 1991;72(5):288-91.
  27. Revel M, Minguet M, Gergoy P et al. Changes in cervicocephalic kinesthesia after a proprioceptive rehabilitation program in patients with neck pain: A randomized controlled study. Arch Phys Med Rehabil. 1994;75(8):895-9. https://doi.org/10.1016/0003-9993(94)90115-5
  28. Rogers RG. The effects of spinal manipulation on cervical kinaesthesia in patients with chronic neck pain: A pilot study. J Manipulative Physiol Ther. 1997;20(2):80-5.
  29. Ashton-Miller JA, McGlashen KM, Schultz AB. Trunk positioning accuracy in children 7-18 years old. J Orthop Res. 1992;10(2):217-25. https://doi.org/10.1002/jor.1100100209
  30. Kara B, GenC A, Yildirim Y et al. Use of tape measure in people with or without back pain in assessment of reposition error. Turk Neurosurg 2011;21(3):290-5.
  31. Jakobs T, Miller JAA, Schultz AB. Trunk position sense in the frontal plane. Exp Neurol. 1985;90(1):129-38. https://doi.org/10.1016/0014-4886(85)90046-9
  32. Bo-Kyung Song. Effect of somatosensory stimulation on upper limb in sensory, hand function, postural control and ADLs within sensorimotor deficits after stroke. J Kor Soc Phys Ther. 2012;24(5):291-9. https://doi.org/10.1589/jpts.24.291
  33. Docherty CL, Arnold BL, Zinder SM et al. Relationship between two proprioceptive measures and stiffness at the ankle. J Electromyogr Kinesiol. 2004;14(3):317-24. https://doi.org/10.1016/S1050-6411(03)00035-X