References
- Bolla E, Muratore F, Carano A, Bowman SJ. Evaluation of maxillary molar distalization with the distal jet: a comparison with other contemporary methods. Angle Orthod 2002;72:481-94.
- Bondemark L, Karlsson I. Extraoral vs intraoral appliance for distal movement of maxillary first molars: a randomized controlled trial. Angle Orthod 2005;75:699-706.
- Haydar S, Uner O. Comparison of Jones jig molar distalization appliance with extraoral traction. Am J Orthod Dentofacial Orthop 2000;117:49-53. https://doi.org/10.1016/S0889-5406(00)70247-2
- Angelieri F, de Almeida RR, Janson G, Castanha Henriques JF, Pinzan A. Comparison of the effects produced by headgear and pendulum appliances followed by fixed orthodontic treatment. Eur J Orthod 2008;30:572-9. https://doi.org/10.1093/ejo/cjn060
- El-Mangoury NH. Orthodontic cooperation. Am J Orthod 1981;80:604-22. https://doi.org/10.1016/0002-9416(81)90264-5
- Egolf RJ, BeGole EA, Upshaw HS. Factors associated with orthodontic patient compliance with intraoral elastic and headgear wear. Am J Orthod Dentofacial Orthop 1990;97:336-48. https://doi.org/10.1016/0889-5406(90)70106-M
- Koltun A, Stone GC. Past and current trends in patient noncompliance research: focus on diseases, regimens-programs, and provider-disciplines. J Compliance Health Care 1986;1:21-32.
- Nanda RS, Kierl MJ. Prediction of cooperation in orthodontic treatment. Am J Orthod Dentofacial Orthop 1992;102:15-21. https://doi.org/10.1016/0889-5406(92)70010-8
- Cureton SL, Regennitter FJ, Yancey JM. Clinical versus quantitative assessment of headgear compliance. Am J Orthod Dentofacial Orthop 1993;104: 277-84. https://doi.org/10.1016/S0889-5406(05)81731-7
- Itoh T, Tokuda T, Kiyosue S, Hirose T, Matsumoto M, Chaconas SJ. Molar distalization with repelling magnets. J Clin Orthod 1991;25:611-7.
- Gianelly AA, Bednar J, Dietz VS. Japanese NiTi coils used to move molars distally. Am J Orthod Dentofacial Orthop 1991;99:564-6. https://doi.org/10.1016/S0889-5406(05)81633-6
- Ghosh J, Nanda RS. Evaluation of an intraoral maxillary molar distalization technique. Am J Orthod Dentofacial Orthop 1996;110:639-46. https://doi.org/10.1016/S0889-5406(96)80041-2
- Carano A, Testa M, Bowman SJ. The distal jet simplified and updated. J Clin Orthod 2002;36:586-90
- Locatelli R, Bednar J, Dietz VS, Gianelly AA. Molar distalization with superelastic NiTi wire. J Clin Orthod 1992;26:277-9.
- Kalra V. The K-loop molar distalizing appliance. J Clin Orthod 1995;29:298-301.
- Ludwig B, Glasl B, Kinzinger GS, Walde KC, Lisson JA. The skeletal frog appliance for maxillary molar distalization. J Clin Orthod 2011;45:77-84.
- Orton HS, Battagel JM, Ferguson R, Ferman AM. Distal movement of buccal segments with the "en masse" removable appliance-its value in treating patients with mild Class II, Division 1 malocclusions: Part I, clinical techniques (how to do it). Am J Orthod Dentofacial Orthop 1996;109:234-43. https://doi.org/10.1016/S0889-5406(96)70146-4
- Polat-Ozsoy O, Gokcelik A, Gungor-Acar A, Kircelli BH. Soft tissue profile after distal molar movement with a pendulum K-loop appliance versus cervical headgear. Angle Orthod 2008;78:317-23. https://doi.org/10.2319/011107-10.1
- Ricketts RM, Bench RW, Gugino CF, Hilgers JJ, Schulhof RJ. Bioprogressive therapy. 1st ed. Denver: Colo: Rocky Mountain Orthodontics Inc.; 1979. p. 249-54.
- Dahlberg G. Statistical methods for medical and biological students. New York: Interscience Publications; 1940.
- Bayram M, Nur M, Kilkis D. The frog appliance for upper molar distalization: a case report. Korean J Orthod 2010;40:50-60. https://doi.org/10.4041/kjod.2010.40.1.50
- Chiu PP, McNamara JA Jr, Franchi L. A comparison of two intraoral molar distalization appliances: distal jet versus pendulum. Am J Orthod Dentofacial Orthop 2005;128:353-65. https://doi.org/10.1016/j.ajodo.2004.04.031
- Bussick TJ, McNamara JA Jr. Dentoalveolar and skeletal changes associated with the pendulum appliance. Am J Orthod Dentofacial Orthop 2000; 117:333-43. https://doi.org/10.1016/S0889-5406(00)70238-1
- Patel MP, Janson G, Henriques JF, de Almeida RR, de Freitas MR, Pinzan A, et al. Comparative distalization effects of Jones jig and pendulum appliances. Am J Orthod Dentofacial Orthop 2009; 135:336-42. https://doi.org/10.1016/j.ajodo.2007.01.035
- Kinzinger GS, Gross U, Fritz UB, Diedrich PR. Anchorage quality of deciduous molars versus premolars for molar distalization with a pendulum appliance. Am J Orthod Dentofacial Orthop 2005; 127:314-23. https://doi.org/10.1016/j.ajodo.2004.09.014
- Brickman CD, Sinha PK, Nanda RS. Evaluation of the Jones jig appliance for distal molar movement. Am J Orthod Dentofacial Orthop 2000;118:526-34. https://doi.org/10.1067/mod.2000.110332
- Ngantung V, Nanda RS, Bowman SJ. Posttreatment evaluation of the distal jet appliance. Am J Orthod Dentofacial Orthop 2001;120:178-85. https://doi.org/10.1067/mod.2001.114645
Cited by
- Skeletal and dental effects of molar distalization using a modified palatal anchorage plate in adolescents vol.85, pp.4, 2013, https://doi.org/10.2319/060114-392.1
- A New Orthodontic Appliance with a Mini Screw for Upper Molar Distalization vol.2016, pp.None, 2013, https://doi.org/10.1155/2016/5728382
- Evaluation of Palatal Bone Thickness for Insertion of Orthodontic Mini-Implants in Adults and Adolescents vol.28, pp.6, 2017, https://doi.org/10.1097/scs.0000000000003906
- Comparison of Treatment Effects with Modified C-Palatal Plates vs Greenfield Molar Distalizer Appliances in Adolescents vol.44, pp.3, 2020, https://doi.org/10.17796/1053-4625-44.3.12
- New Method for Analysis of the Temporomandibular Joint Using Cone Beam Computed Tomography vol.21, pp.9, 2013, https://doi.org/10.3390/s21093070