References
- Abrams, D., Smith, T., Lynch, J. and Franklin, S. (2007), "Effectiveness of rehabilitation on seismic behavior of masonry piers", J. Struct. Eng. - ASCE, 133(1), 32-43. https://doi.org/10.1061/(ASCE)0733-9445(2007)133:1(32)
- Anagnostopoulos, C.A. and Anagnostopoulos, A.C. (2002), "Polymer-cement mortars for repairing ancient masonries mechanical properties", Constr. Build. Mater., 16(7), 379-384. https://doi.org/10.1016/S0950-0618(02)00040-5
- Ashraf, M., Khan, A.N., Naseer, A., Ali, Q. and Alam, B. (2012), "Seismic behavior of unreinforced and confined brick masonry walls before and after ferrocement overlay retrofitting", Int.. J. Archit. Heritage, 6(6), 665-688. https://doi.org/10.1080/15583058.2011.599916
- Calderini, C. (2008), "Use of reinforced concrete in preservation of historic buildings: conceptions and misconceptions in the early 20th century", Int.. J. Archit. Heritage, 2(1), 25-59. https://doi.org/10.1080/15583050701533521
- Curti, E., Podesta, S. and Resemini, S. (2008), "The post-earthquake reconstruction process of monumental masonry buildings: Suggestions from the Molise event (Italy)", Int.. J. Archit. Heritage, 2(2), 120-154. https://doi.org/10.1080/15583050701646703
- DIANA (2008), DIANA User's Manual Release 9.., TNO DIANA BV, Delft, Netherlands.
- Faella, C., Martinelli, E., Nigro, E. and Paciello, S. (2010), "Shear capacity of masonry walls externally strengthened by a cement-based composite material: An experimental campaign", Constr. Build. Mater., 24(1), 84-93. https://doi.org/10.1016/j.conbuildmat.2009.08.019
- Fowler, D.W. (1999), "Polymers in concrete: a vision for the 21st century", Cement Concrete Comp., 21(5-6), 449-452. https://doi.org/10.1016/S0958-9465(99)00032-3
- Kikuchi, K., Kuroki, K., Toyodome, M., Escobar, C. and Nakano, Y. (2008), "Seismic retrofit of unreinforced clay brick masonry wall using polymer-cement mortar", Proceedings of 14th World Conference on Earthquake Engineering, Beijing, China, October.
- Lourenco, P.B. and Rots, J.G. (1997), "Multisurface interface model for analysis of masonry structures", J. Eng. Mech., 123(7), 660-668. https://doi.org/10.1061/(ASCE)0733-9399(1997)123:7(660)
- Maranhao, F.L. and John, V.M. (2009), "Bond strength and transversal deformation aging on cement-polymer adhesive mortar", Constr. Build. Mater., 23(2), 1022-1027. https://doi.org/10.1016/j.conbuildmat.2008.05.019
- Ohama, Y. (1995), Handbook of polymer-modified concrete and mortar, properties and process technology, Noyes Publications, New Jersey, USA.
- Ohama, Y. (1998), "Polymer-based admixtures", Cement Concrete Comp., 20(2-3), 189-212. https://doi.org/10.1016/S0958-9465(97)00065-6
- Oliveira, D.V., Lourenco, P.B. and Roca, P. (2006), "Cyclic behaviour of stone and brick masonry under uniaxial compressive loading", Mater. Struct., 39(286), 247-257.
- Pareek, S. and Kuroda, K. (2003), "Evaluation of polymer-cement pastes as bonding agents for flexural strengthening of RC beams by continuous fiber sheets", Proceedings of Intern. Symposium on Latest Achievement of Techno. Rese. Retrofitting Concrete Struct., Kyoto, Japan.
- Shrestha, K.C., Nagae, T. and Araki, Y. (2011a), "Finite element modeling of cyclic out-of-plane response of masonry walls retrofitted by inserting inclined stainless steel bars", J. Disaster Res., 6(1), 36-43. https://doi.org/10.20965/jdr.2011.p0036
- Shrestha, K.C., Nagae, T. and Araki, Y. (2011b), "Finite element study on pinning retrofitting technique of masonry walls with opening subjected to in-plane shear load", ACEE- J., 4(4), 81-96.
- Shrestha, K.C., Araki, Y., Nagae, T., Omori, T., Sutou, Y., Kainuma, R. and Ishida, K. (2011c), "Applicability of Cu-Al-Mn shape memory alloy bars to retrofitting of historical masonry constructions", Earthq. Struct., 2(3), 233-256. https://doi.org/10.12989/eas.2011.2.3.233
- Shrestha, K.C., Araki, Y., Nagae, T., Omori, T., Sutou, Y., Kainuma, R. and Ishida, K. (2013), "Effectiveness of superelastic bars for seismic rehabilitation of clay-unit masonry walls", Earthq. Eng. Struct. Dyn., 42(5), 725-741. https://doi.org/10.1002/eqe.2241
- Takiyama, N., Nagae, T., Maeda, H., Kitamura, M., Yoshida, N. and Araki, Y. (2008), "Cyclic out-of-plane flexural behavior of masonry walls rehabilitated by inserting steel pins", Proceedings of 14th World
- Conference on Earthq. Eng., Beijing, China, October. Willis, C.R., Seracino, R. and Griffith, M.C. (2010), "Out-of-plane strength of brick masonry retrofitted with horizontal NSM CFRP strips", Eng. Struct., 32(2), 547-555. https://doi.org/10.1016/j.engstruct.2009.10.015
Cited by
- Assessment of out-of-plane behavior of rammed earth walls by pull-down tests pp.1558-3066, 2019, https://doi.org/10.1080/15583058.2018.1433903
- In-Plane Shear Resistance between the Rammed Earth Blocks with Simple Interventions: Experimentation and Finite Element Study vol.10, pp.3, 2013, https://doi.org/10.3390/buildings10030057
- Ultimate shear strength prediction model for unreinforced masonry retrofitted externally with textile reinforced mortar vol.19, pp.6, 2013, https://doi.org/10.12989/eas.2020.19.6.411