초록

The trace toxic metal copper was assayed using mercury immobilized on a carbon nanotube electrode (MCW), with a graphite counter and a reference electrode. In this study, a macro-scale convection motor was interfaced with a MCW three-electrode system, in which a handmade MCW was optimized using cyclic- and square-wave stripping voltammetry. An analytical electrolyte for tap water was used instead of an expensive acid or base ionic solution. Under these conditions, optimum parameters were 0.09 V amplitude, 40 Hz frequency, 0.01 V incremental potential, and a 60-s accumulation time. A diagnostic working curve was obtained from 50.0 to 350 ${\mu}g/L$. At a constant Cu(II) concentration of 10.0 ${\mu}g/L$, the statistical relative standard deviation was 1.78% (RSD, n = 15), the analytical accumulation time was only 60 s, and the analytical detection limit approached 4.6 ${\mu}g/L$ (signal/noise = 3). The results were applied to non-treated drinking water. The content of the analyzed copper using 9.0 and 4.0 ${\mu}g/L$ standards were 8.68 ${\mu}g/L$ and 3.96 ${\mu}g/L$; statistical values $R^2$ = 0.9987 and $R^2$ = 0.9534, respectively. This method is applicable to biological diagnostics or food surveys.

키워드

참고문헌

  1. Becaria, A., Lahiri, D.K., Bondy, S.C., Chen, D., Hamadeh, A., Li, H., Taylor, R. and Campbell, A. (2006) Aluminum and copper in drinking water enhance inflammatory or oxidative events specifically in the brain. J. Neuroimmunol., 176, 16-23. https://doi.org/10.1016/j.jneuroim.2006.03.025
  2. Malek, F., Jiresova, E., Dohnalova, A., Koprivova, H. and Spacek, R. (2006) Serum copper as a marker of inflammation in prediction of short term outcome in high risk patients with chronic heart failure. Int. J. Cardiol., 113, e51-e53. https://doi.org/10.1016/j.ijcard.2006.05.022
  3. Dieter, H.H., Bayer, T.A. and Multhaup, G. (2005) Environmental Copper and Manganese in the pathophysiology of Neurologic Diseases (Alzheimer's Disease and Manganism). Acta Hydrochim. Hydrobiol., 33, 7278.
  4. Xu, J., Yang, L., Wang, Z., Dong, G., Huang, J. and Wang, Y. (2006) Toxicity of copper on rice growth and accumulation of copper in rice grain in copper contaminated soil. Chemosphere, 62, 602-607. https://doi.org/10.1016/j.chemosphere.2005.05.050
  5. Teixeira, L.S., Rocha, R.B., Sobrinho, E.V., Guimaraes, P.R., Pontes, L.A. and Teixeira, J.S. (2007) Simultaneous determination of copper and iron in automotive gasoline by X-ray fluorescence after pre-concentration on cellulose paper. Talanta, 72, 1073-1076. https://doi.org/10.1016/j.talanta.2006.12.042
  6. Miller, L.M., Wang, Q., Telivala, T.P., Smith, R.J., Lanzirotti, A. and Miklossy, J. (2006) Synchrotron-based infrared and Xray imaging shows focalized accumulation of Cu and Zn colocalized with beta-amyloid deposits in Alzheimers disease. J. Struct. Biol., 155, 30-37. https://doi.org/10.1016/j.jsb.2005.09.004
  7. Lara, R., Cerutti, S., Salonia, J.A., Olsina, R.A. and Martinez, L.D. (2005) Trace element determination of Argentine wines using ETAAS and USN-ICP-OES. Food Chem. Toxicol., 43, 293-297. https://doi.org/10.1016/j.fct.2004.10.004
  8. Perring, L., Andrey, D., Basic-Dvorzak, M. and Hammer, D. (2005) Rapid quantification of iron, copper and zinc in food premixes using energy dispersive X-ray fluorescences. J. Food Compos. Anal., 18, 655-663. https://doi.org/10.1016/j.jfca.2004.06.011
  9. Ly, S.Y. (2006) Detection of dopamine in the pharmacy with a carbon nanotube paste electrode using voltammetry. Bioelectrochemistry, 68, 227-231. https://doi.org/10.1016/j.bioelechem.2005.09.002
  10. Takeuchi, R.M., Santos, A.L., Padilha, P.M. and Stradiotto, N.R. (2007) Copper determination in ethanol fuel by differential pulse anodic stripping voltammetry at a solid paraffinbased carbon paste electrode modified with 2-aminothiazole organofunctionalized silica. Talanta, 71, 771-777. https://doi.org/10.1016/j.talanta.2006.05.035
  11. Ly, S.Y., Song, S.S., Kim, S.K., Jung, Y.S. and Lee, C.H. (2006) Rmination of Ge(IV) in rice in a mercury coated glassy carbon electrode in the presence of catechol. Food Chem., 95, 337-343. https://doi.org/10.1016/j.foodchem.2005.02.029
  12. Ly, S.Y., Jung, Y.S., Kim, S.K. and Lee, H.K. (2007) Trace analysis of lead and copper ions in fish tissue using paste electrodes. Anal. Lett., 40, 2683-2692. https://doi.org/10.1080/00032710701588184