DOI QR코드

DOI QR Code

Smart passive control of buildings with higher redundancy and robustness using base-isolation and inter-connection

  • Murase, Mitsuru (Department of Architecture and Architectural Engineering, Kyoto University) ;
  • Tsuji, Masaaki (Department of Architecture and Architectural Engineering, Kyoto University) ;
  • Takewaki, Izuru (Department of Architecture and Architectural Engineering, Kyoto University)
  • 투고 : 2012.09.30
  • 심사 : 2013.02.23
  • 발행 : 2013.06.25

초록

It is known that a base-isolated building exhibits a large response to a long-duration, long-period wave and an inter-connected system without base-isolation shows a large response to a pulse-type wave. To compensate for each deficiency, a new hybrid passive control system is investigated in which a base-isolated building is connected to another building (free wall) with oil dampers. It is demonstrated that the present hybrid passive control system is effective both for pulse-type ground motions and long-duration and long-period ground motions and has high redundancy and robustness for a broad range of disturbances.

키워드

과제정보

연구 과제 주관 기관 : Japan Society for the Promotion of Science

참고문헌

  1. Architectural Institute of Japan (AIJ) (2011), "Structural design with higher robustness and redundancy", J. Architect. Build. Sci., 126(1624), 73-79. (in Japanese)
  2. Ariga, T., Kanno, Y. and Takewaki, I. (2006), "Resonant behavior of base-isolated high-rise buildings under long-period ground motions", Struct. Des. Tall Spec. Build., 15(3), 325-338. https://doi.org/10.1002/tal.298
  3. Ben-Haim, Y. (2001, 2006), Infomation-gap decision theory: Decisions under severe uncertainty, Adacemic Press, London.
  4. Committee on National Earthquake Resilience Research, Implementation, and Outreach (2011), Committee on Seismology and Geodynamics, National Research Council, National Earthquake Resilience: Research, Implementation, and Outreach, The National Academy's Press.
  5. Elishakoff, I. and Ohsaki, M. (2010), Optimization and anti-optimization of structures under uncertainty, Imperial College Press.
  6. Hall, J.H., Heaton, T.H., Halling, M.W. and Wald, D.J. (1995), "Near-source ground motion and its effect on flexible buildings", Earthq. Spectra, 11, 569-605. https://doi.org/10.1193/1.1585828
  7. He, W.L. (2003), "Smart energy dissipation systems for protection of civil infrastructures from near-field earthquakes". Ph.D. Dissertation, The City Univ. of New York, New York.
  8. He, W.L. and Agrawal, A.K. (2008), "Analytical model of ground motion pulses for the design and assessment of seismic protective systems", J. Struct. Eng., ASCE, 134(7), 1177-1188. https://doi.org/10.1061/(ASCE)0733-9445(2008)134:7(1177)
  9. Heaton, T.H., Hall, J.H., Wald, D.J. and Halling, M.W. (1995), "Response of high-rise and base-isolated buildings in a hypothetical MW 7.0 blind thrust earthquake", Sci., 267, 206-211. https://doi.org/10.1126/science.267.5195.206
  10. Hino, J., Yoshitomi, S., Tsuji, M. and Takewaki, I. (2008), "Bound of aspect ratio of base-isolated buildings considering nonlinear tensile behavior of rubber bearing", Struct. Eng. Mech., 30(3), 351-368. https://doi.org/10.12989/sem.2008.30.3.351
  11. Irikura, K., Kamae, K. and Kawabe, H. (2004), "Importance of prediction of long-period ground motion during large earthquakes", In Annual Conference of the Seismological Society of Japan, Poster Session. (in Japanese)
  12. Jangid, R.S. (1995), "Optimum isolator damping for minimum acceleration response of base-isolated structures", Australian Civil Eng. Transact., 37, 325-331.
  13. Jangid, R.S. and Banerji, P. (1998), "Effects of isolation damping on stochastic response of structures with nonlinear base isolators", Earthq. Spectra., 14, 95-114. https://doi.org/10.1193/1.1585990
  14. Jangid, R.S. and Datta, T.K. (1994), "Non-linear response of torsionally coupled base isolated structure", J. Struct. Eng., ASCE, 120, 1-22. https://doi.org/10.1061/(ASCE)0733-9445(1994)120:1(1)
  15. Jangid, R.S. and Kelly, J.M. (2001), "Base isolation for near-fault motions", Earthq. Eng. Struct. Dyn., 30, 691-707. https://doi.org/10.1002/eqe.31
  16. Kamae, K., Kawabe, H. and Irikura, K. (2004), "Strong ground motion prediction for huge subduction earthquakes using a characterized source model and several simulation techniques", In Proceedings of the13th WCEE, Vancouver.
  17. Karabork, T. (2011), "Performance of multi-storey structures with high damping rubber bearing base isolation systems", Struct. Eng. Mech., 39(3), 399-410. https://doi.org/10.12989/sem.2011.39.3.399
  18. Kelly, J.M. (1999), "The role of damping in seismic isolation", Earthq. Eng. Struct. D., 28, 3-20. https://doi.org/10.1002/(SICI)1096-9845(199901)28:1<3::AID-EQE801>3.0.CO;2-D
  19. Kobori, T. (2004), Seismic-Response-Controlled Structure (New edition), Kajima Publisher, Tokyo. (in Japanese)
  20. Koo, J.H., Jang, D.D., Usman, M. and Jung, H.J. (2009), "A feasibility study on smart base isolation systems using magneto-rheological elastomers", Struct. Eng. Mech., 32(6), 755-770. https://doi.org/10.12989/sem.2009.32.6.755
  21. Li, H.N. and Wu, X.X. (2006), "Limitations of height-to-width ratio for base-isolated buildings under earthquake", Struct. Des. Tall Spec. Buildings, 15, 277-287. https://doi.org/10.1002/tal.295
  22. Morales, C.A. (2003), "Transmissibility concept to control base motion in isolated structures", Eng. Struct., 25(10), 1325-1331. https://doi.org/10.1016/S0141-0296(03)00084-1
  23. Naeim, F. and Kelly, J.M. (1999), Design of Seismic Isolated Structures, Wiley, New York.
  24. Nishimura, K, Fukumoto, Y and Wada, Y. (2008), "Response control effect of hi-rised reinforced concrete building using couplaed vibration control structure", J. Technol. Des., AIJ, 14(28), 417-422. (in Japanese) https://doi.org/10.3130/aijt.14.417
  25. Nishimura, K., Fukumoto, Y., Sasamoto, K. and Tanaka, Y. (2011), "Base-isolated building with higher robustness and redundancy enhanced by inter-connecting dampers", J. Architec Build. Sci., 126(1624), 79. (in Japanese)
  26. Patel, C.C. and Jangid, R.S. (2011), "Dynamic response of adjacent structures connected by friction dampers", Earthq. Struct., 2(2), 149-169. https://doi.org/10.12989/eas.2011.2.2.149
  27. Petti, L., De Iuliis, G.G.M. and Palazzo, B. (2010), "Small scale experimental testing to verify the effectiveness of the base isolation and tuned mass dampers combined control strategy", Smart Struct. Sys., 6(1), 57-72. https://doi.org/10.12989/sss.2010.6.1.057
  28. Takewaki, I. (2005), "Uncertain-parameter sensitivity of earthquake input energy to base-isolated structure", Struct. Eng. Mech., 20(3), 347-362. https://doi.org/10.12989/sem.2005.20.3.347
  29. Takewaki, I. (2006), "Critical excitation methods in earthquake engineering", Elsevier Sci., Amsterdam.
  30. Takewaki, I. (2007), "Earthquake input energy to two buildings connected by viscous dampers", J. Struct. Eng., ASCE, 133(5), 620-628. https://doi.org/10.1061/(ASCE)0733-9445(2007)133:5(620)
  31. Takewaki, I. (2008), "Robustness of base-isolated high-rise buildings under code-specified ground motions", Struct. Des. Tall Spec. Build., 17(2), 257-271. https://doi.org/10.1002/tal.350
  32. Takewaki, I. and Fujita, K. (2009), "Earthquake input energy to tall and base-isolated buildings in time and frequency dual domains", Struct. Des. Tall Spec. Build., 18(6), 589-606. https://doi.org/10.1002/tal.497
  33. Takewaki, I. and Tsujimoto, H. (2011), "Scaling of design earthquake ground motions for tall buildings based on drift and input energy demands", Earthq. Struct., 2(2), 171-187. https://doi.org/10.12989/eas.2011.2.2.171
  34. Takewaki, I., Murakami, S., Fujita, K., Yoshitomi, S. and Tsuji, M. (2011), "The 2011 off the Pacific coast of Tohoku earthquake and response of high-rise buildings under long-period ground motions", Soil Dyn. Earthq. Eng., 31(11), 1511-1528. https://doi.org/10.1016/j.soildyn.2011.06.001
  35. Takewaki, I., Moustafa, A. and Fujita, K. (2012a), Improving the earthquake resilience of buildings: The worst case approach, Springer, London.
  36. Takewaki, I., Fujita, K. and Yoshitomi, S. (2012b), "Uncertainties in long-period ground motion and its impact on building structural design: Case study of the 2011 Tohoku (Japan) earthquake", Eng. Struct. (accepted for publication)
  37. Xu, Z., Agrawal, A.K., He, W.L. and Tan, P. (2007), "Performance of passive energy dissipation systems during near-field ground motion type pulses", Eng. Struct., 29, 224-236. https://doi.org/10.1016/j.engstruct.2006.04.020

피인용 문헌

  1. Dual Control High-rise Building for Robuster Earthquake Performance vol.3, 2017, https://doi.org/10.3389/fbuil.2017.00012
  2. Critical earthquake input energy to connected building structures using impulse input vol.9, pp.6, 2015, https://doi.org/10.12989/eas.2015.9.6.1133
  3. Integrated Design of Hybrid Interstory-Interbuilding Multi-Actuation Schemes for Vibration Control of Adjacent Buildings under Seismic Excitations vol.7, pp.4, 2017, https://doi.org/10.3390/app7040323
  4. Automatic generation of smart earthquake-resistant building system: Hybrid system of base-isolation and building-connection vol.2, pp.2, 2016, https://doi.org/10.1016/j.heliyon.2016.e00069
  5. A New Transmissibility Analysis Method for Detection and Location of Damage via Nonlinear Features in MDOF Structural Systems vol.20, pp.4, 2015, https://doi.org/10.1109/TMECH.2014.2359419
  6. Life-Cycle Cost Model and Design Optimization of Base-Isolated Building Structures vol.2, 2016, https://doi.org/10.3389/fbuil.2016.00027
  7. Experimental Study on Influence of Hardening of Isolator in Multiple Isolation Building vol.2, 2016, https://doi.org/10.3389/fbuil.2016.00012
  8. Lyapunov-based Semi-active Control of Adaptive Base Isolation System employing Magnetorheological Elastomer base isolators vol.11, pp.6, 2016, https://doi.org/10.12989/eas.2016.11.6.1077
  9. Effect of Non-linearity of Connecting Dampers on Vibration Control of Connected Building Structures vol.1, 2016, https://doi.org/10.3389/fbuil.2015.00025
  10. Hybrid Control System for Greater Resilience Using Multiple Isolation and Building Connection vol.2, 2016, https://doi.org/10.3389/fbuil.2016.00026
  11. Magnetorheological elastomer base isolator for earthquake response mitigation on building structures: modeling and second-order sliding mode control vol.11, pp.6, 2016, https://doi.org/10.12989/eas.2016.11.6.943
  12. Innovative Seismic Response-Controlled System with Shear Wall and Concentrated Dampers in Lower Stories vol.3, 2017, https://doi.org/10.3389/fbuil.2017.00057
  13. Development of a High Precision Displacement Measurement System by Fusing a Low Cost RTK-GPS Sensor and a Force Feedback Accelerometer for Infrastructure Monitoring vol.17, pp.12, 2017, https://doi.org/10.3390/s17122745
  14. Building earthquake resilience in sustainable cities in terms of input energy vol.12, 2014, https://doi.org/10.1016/j.scs.2014.01.004
  15. Swing Story–Lateral Force Resisting System Connected with Dampers: Novel Seismic Vibration Control System for Building Structures vol.144, pp.2, 2018, https://doi.org/10.1061/(ASCE)EM.1943-7889.0001390
  16. SEISMIC CHARACTERISTICS OF MULTIPLE ISOLATION BUILDING WITH PLURAL ISOLATION STORIES vol.79, pp.705, 2013, https://doi.org/10.3130/aijs.79.1613
  17. Shaking table test and verification of development of an accumulated semi-active hydraulic damper as an active interaction control device vol.41, pp.12, 2016, https://doi.org/10.1007/s12046-016-0570-z
  18. The study of frictional damper with various control algorithms vol.12, pp.5, 2013, https://doi.org/10.12989/eas.2017.12.5.479
  19. MECHANISM OF RESPONSE REDUCTION IN HYBRID CONTROL SYSTEM OF BASE-ISOLATED BUILDING CONNECTED TO FREE-WALL WITH DAMPER vol.82, pp.737, 2013, https://doi.org/10.3130/aijs.82.1023
  20. A Simple Response Evaluation Method for Base-Isolation Building-Connection Hybrid Structural System under Long-Period and Long-Duration Ground Motion vol.4, pp.None, 2013, https://doi.org/10.3389/fbuil.2018.00002
  21. Robustness Evaluation of Base-Isolation Building-Connection Hybrid Controlled Building Structures Considering Uncertainties in Deep Ground vol.4, pp.None, 2013, https://doi.org/10.3389/fbuil.2018.00016
  22. Critical Ground Motion for Resilient Building Design Considering Uncertainty of Fault Rupture Slip vol.4, pp.None, 2013, https://doi.org/10.3389/fbuil.2018.00064
  23. Finite Difference Method-Based Critical Ground Motion and Robustness Evaluation for Long-Period Building Structures Under Uncertainty in Fault Rupture vol.5, pp.None, 2013, https://doi.org/10.3389/fbuil.2019.00002
  24. Simultaneous Approach to Critical Fault Rupture Slip Distribution and Optimal Damper Placement for Resilient Building Design vol.5, pp.None, 2013, https://doi.org/10.3389/fbuil.2019.00126
  25. Optimum design of viscous dampers to prevent pounding of adjacent structures vol.16, pp.4, 2013, https://doi.org/10.12989/eas.2019.16.4.437
  26. The effect of base isolation and tuned mass dampers on the seismic response of RC high-rise buildings considering soil-structure interaction vol.17, pp.4, 2013, https://doi.org/10.12989/eas.2019.17.4.425
  27. Smart Seismic Control System for High-Rise Buildings Using Large-Stroke Viscous Dampers Through Connection to Strong-Back Core Frame vol.6, pp.None, 2013, https://doi.org/10.3389/fbuil.2020.00029
  28. Seismic retrofit of steel buildings using external resistant RC walls and friction dampers vol.76, pp.6, 2020, https://doi.org/10.12989/sem.2020.76.6.823
  29. A Simple Critical Response Evaluation Method for Base-Isolation Building-Connection Hybrid System Under Double Impulse as Representative of Near-Fault Ground Motion vol.7, pp.None, 2013, https://doi.org/10.3389/fbuil.2021.790584
  30. Seismic Resistance and Parametric Study of Building under Control of Impulsive Semi-Active Mass Damper vol.11, pp.6, 2013, https://doi.org/10.3390/app11062468