과제정보
연구 과제 주관 기관 : Japan Society for the Promotion of Science
참고문헌
- Architectural Institute of Japan (AIJ) (2011), "Structural design with higher robustness and redundancy", J. Architect. Build. Sci., 126(1624), 73-79. (in Japanese)
- Ariga, T., Kanno, Y. and Takewaki, I. (2006), "Resonant behavior of base-isolated high-rise buildings under long-period ground motions", Struct. Des. Tall Spec. Build., 15(3), 325-338. https://doi.org/10.1002/tal.298
- Ben-Haim, Y. (2001, 2006), Infomation-gap decision theory: Decisions under severe uncertainty, Adacemic Press, London.
- Committee on National Earthquake Resilience Research, Implementation, and Outreach (2011), Committee on Seismology and Geodynamics, National Research Council, National Earthquake Resilience: Research, Implementation, and Outreach, The National Academy's Press.
- Elishakoff, I. and Ohsaki, M. (2010), Optimization and anti-optimization of structures under uncertainty, Imperial College Press.
- Hall, J.H., Heaton, T.H., Halling, M.W. and Wald, D.J. (1995), "Near-source ground motion and its effect on flexible buildings", Earthq. Spectra, 11, 569-605. https://doi.org/10.1193/1.1585828
- He, W.L. (2003), "Smart energy dissipation systems for protection of civil infrastructures from near-field earthquakes". Ph.D. Dissertation, The City Univ. of New York, New York.
- He, W.L. and Agrawal, A.K. (2008), "Analytical model of ground motion pulses for the design and assessment of seismic protective systems", J. Struct. Eng., ASCE, 134(7), 1177-1188. https://doi.org/10.1061/(ASCE)0733-9445(2008)134:7(1177)
- Heaton, T.H., Hall, J.H., Wald, D.J. and Halling, M.W. (1995), "Response of high-rise and base-isolated buildings in a hypothetical MW 7.0 blind thrust earthquake", Sci., 267, 206-211. https://doi.org/10.1126/science.267.5195.206
- Hino, J., Yoshitomi, S., Tsuji, M. and Takewaki, I. (2008), "Bound of aspect ratio of base-isolated buildings considering nonlinear tensile behavior of rubber bearing", Struct. Eng. Mech., 30(3), 351-368. https://doi.org/10.12989/sem.2008.30.3.351
- Irikura, K., Kamae, K. and Kawabe, H. (2004), "Importance of prediction of long-period ground motion during large earthquakes", In Annual Conference of the Seismological Society of Japan, Poster Session. (in Japanese)
- Jangid, R.S. (1995), "Optimum isolator damping for minimum acceleration response of base-isolated structures", Australian Civil Eng. Transact., 37, 325-331.
- Jangid, R.S. and Banerji, P. (1998), "Effects of isolation damping on stochastic response of structures with nonlinear base isolators", Earthq. Spectra., 14, 95-114. https://doi.org/10.1193/1.1585990
- Jangid, R.S. and Datta, T.K. (1994), "Non-linear response of torsionally coupled base isolated structure", J. Struct. Eng., ASCE, 120, 1-22. https://doi.org/10.1061/(ASCE)0733-9445(1994)120:1(1)
- Jangid, R.S. and Kelly, J.M. (2001), "Base isolation for near-fault motions", Earthq. Eng. Struct. Dyn., 30, 691-707. https://doi.org/10.1002/eqe.31
- Kamae, K., Kawabe, H. and Irikura, K. (2004), "Strong ground motion prediction for huge subduction earthquakes using a characterized source model and several simulation techniques", In Proceedings of the13th WCEE, Vancouver.
- Karabork, T. (2011), "Performance of multi-storey structures with high damping rubber bearing base isolation systems", Struct. Eng. Mech., 39(3), 399-410. https://doi.org/10.12989/sem.2011.39.3.399
- Kelly, J.M. (1999), "The role of damping in seismic isolation", Earthq. Eng. Struct. D., 28, 3-20. https://doi.org/10.1002/(SICI)1096-9845(199901)28:1<3::AID-EQE801>3.0.CO;2-D
- Kobori, T. (2004), Seismic-Response-Controlled Structure (New edition), Kajima Publisher, Tokyo. (in Japanese)
- Koo, J.H., Jang, D.D., Usman, M. and Jung, H.J. (2009), "A feasibility study on smart base isolation systems using magneto-rheological elastomers", Struct. Eng. Mech., 32(6), 755-770. https://doi.org/10.12989/sem.2009.32.6.755
- Li, H.N. and Wu, X.X. (2006), "Limitations of height-to-width ratio for base-isolated buildings under earthquake", Struct. Des. Tall Spec. Buildings, 15, 277-287. https://doi.org/10.1002/tal.295
- Morales, C.A. (2003), "Transmissibility concept to control base motion in isolated structures", Eng. Struct., 25(10), 1325-1331. https://doi.org/10.1016/S0141-0296(03)00084-1
- Naeim, F. and Kelly, J.M. (1999), Design of Seismic Isolated Structures, Wiley, New York.
- Nishimura, K, Fukumoto, Y and Wada, Y. (2008), "Response control effect of hi-rised reinforced concrete building using couplaed vibration control structure", J. Technol. Des., AIJ, 14(28), 417-422. (in Japanese) https://doi.org/10.3130/aijt.14.417
- Nishimura, K., Fukumoto, Y., Sasamoto, K. and Tanaka, Y. (2011), "Base-isolated building with higher robustness and redundancy enhanced by inter-connecting dampers", J. Architec Build. Sci., 126(1624), 79. (in Japanese)
- Patel, C.C. and Jangid, R.S. (2011), "Dynamic response of adjacent structures connected by friction dampers", Earthq. Struct., 2(2), 149-169. https://doi.org/10.12989/eas.2011.2.2.149
- Petti, L., De Iuliis, G.G.M. and Palazzo, B. (2010), "Small scale experimental testing to verify the effectiveness of the base isolation and tuned mass dampers combined control strategy", Smart Struct. Sys., 6(1), 57-72. https://doi.org/10.12989/sss.2010.6.1.057
- Takewaki, I. (2005), "Uncertain-parameter sensitivity of earthquake input energy to base-isolated structure", Struct. Eng. Mech., 20(3), 347-362. https://doi.org/10.12989/sem.2005.20.3.347
- Takewaki, I. (2006), "Critical excitation methods in earthquake engineering", Elsevier Sci., Amsterdam.
- Takewaki, I. (2007), "Earthquake input energy to two buildings connected by viscous dampers", J. Struct. Eng., ASCE, 133(5), 620-628. https://doi.org/10.1061/(ASCE)0733-9445(2007)133:5(620)
- Takewaki, I. (2008), "Robustness of base-isolated high-rise buildings under code-specified ground motions", Struct. Des. Tall Spec. Build., 17(2), 257-271. https://doi.org/10.1002/tal.350
- Takewaki, I. and Fujita, K. (2009), "Earthquake input energy to tall and base-isolated buildings in time and frequency dual domains", Struct. Des. Tall Spec. Build., 18(6), 589-606. https://doi.org/10.1002/tal.497
- Takewaki, I. and Tsujimoto, H. (2011), "Scaling of design earthquake ground motions for tall buildings based on drift and input energy demands", Earthq. Struct., 2(2), 171-187. https://doi.org/10.12989/eas.2011.2.2.171
- Takewaki, I., Murakami, S., Fujita, K., Yoshitomi, S. and Tsuji, M. (2011), "The 2011 off the Pacific coast of Tohoku earthquake and response of high-rise buildings under long-period ground motions", Soil Dyn. Earthq. Eng., 31(11), 1511-1528. https://doi.org/10.1016/j.soildyn.2011.06.001
- Takewaki, I., Moustafa, A. and Fujita, K. (2012a), Improving the earthquake resilience of buildings: The worst case approach, Springer, London.
- Takewaki, I., Fujita, K. and Yoshitomi, S. (2012b), "Uncertainties in long-period ground motion and its impact on building structural design: Case study of the 2011 Tohoku (Japan) earthquake", Eng. Struct. (accepted for publication)
- Xu, Z., Agrawal, A.K., He, W.L. and Tan, P. (2007), "Performance of passive energy dissipation systems during near-field ground motion type pulses", Eng. Struct., 29, 224-236. https://doi.org/10.1016/j.engstruct.2006.04.020
피인용 문헌
- Dual Control High-rise Building for Robuster Earthquake Performance vol.3, 2017, https://doi.org/10.3389/fbuil.2017.00012
- Critical earthquake input energy to connected building structures using impulse input vol.9, pp.6, 2015, https://doi.org/10.12989/eas.2015.9.6.1133
- Integrated Design of Hybrid Interstory-Interbuilding Multi-Actuation Schemes for Vibration Control of Adjacent Buildings under Seismic Excitations vol.7, pp.4, 2017, https://doi.org/10.3390/app7040323
- Automatic generation of smart earthquake-resistant building system: Hybrid system of base-isolation and building-connection vol.2, pp.2, 2016, https://doi.org/10.1016/j.heliyon.2016.e00069
- A New Transmissibility Analysis Method for Detection and Location of Damage via Nonlinear Features in MDOF Structural Systems vol.20, pp.4, 2015, https://doi.org/10.1109/TMECH.2014.2359419
- Life-Cycle Cost Model and Design Optimization of Base-Isolated Building Structures vol.2, 2016, https://doi.org/10.3389/fbuil.2016.00027
- Experimental Study on Influence of Hardening of Isolator in Multiple Isolation Building vol.2, 2016, https://doi.org/10.3389/fbuil.2016.00012
- Lyapunov-based Semi-active Control of Adaptive Base Isolation System employing Magnetorheological Elastomer base isolators vol.11, pp.6, 2016, https://doi.org/10.12989/eas.2016.11.6.1077
- Effect of Non-linearity of Connecting Dampers on Vibration Control of Connected Building Structures vol.1, 2016, https://doi.org/10.3389/fbuil.2015.00025
- Hybrid Control System for Greater Resilience Using Multiple Isolation and Building Connection vol.2, 2016, https://doi.org/10.3389/fbuil.2016.00026
- Magnetorheological elastomer base isolator for earthquake response mitigation on building structures: modeling and second-order sliding mode control vol.11, pp.6, 2016, https://doi.org/10.12989/eas.2016.11.6.943
- Innovative Seismic Response-Controlled System with Shear Wall and Concentrated Dampers in Lower Stories vol.3, 2017, https://doi.org/10.3389/fbuil.2017.00057
- Development of a High Precision Displacement Measurement System by Fusing a Low Cost RTK-GPS Sensor and a Force Feedback Accelerometer for Infrastructure Monitoring vol.17, pp.12, 2017, https://doi.org/10.3390/s17122745
- Building earthquake resilience in sustainable cities in terms of input energy vol.12, 2014, https://doi.org/10.1016/j.scs.2014.01.004
- Swing Story–Lateral Force Resisting System Connected with Dampers: Novel Seismic Vibration Control System for Building Structures vol.144, pp.2, 2018, https://doi.org/10.1061/(ASCE)EM.1943-7889.0001390
- SEISMIC CHARACTERISTICS OF MULTIPLE ISOLATION BUILDING WITH PLURAL ISOLATION STORIES vol.79, pp.705, 2013, https://doi.org/10.3130/aijs.79.1613
- Shaking table test and verification of development of an accumulated semi-active hydraulic damper as an active interaction control device vol.41, pp.12, 2016, https://doi.org/10.1007/s12046-016-0570-z
- The study of frictional damper with various control algorithms vol.12, pp.5, 2013, https://doi.org/10.12989/eas.2017.12.5.479
- MECHANISM OF RESPONSE REDUCTION IN HYBRID CONTROL SYSTEM OF BASE-ISOLATED BUILDING CONNECTED TO FREE-WALL WITH DAMPER vol.82, pp.737, 2013, https://doi.org/10.3130/aijs.82.1023
- A Simple Response Evaluation Method for Base-Isolation Building-Connection Hybrid Structural System under Long-Period and Long-Duration Ground Motion vol.4, pp.None, 2013, https://doi.org/10.3389/fbuil.2018.00002
- Robustness Evaluation of Base-Isolation Building-Connection Hybrid Controlled Building Structures Considering Uncertainties in Deep Ground vol.4, pp.None, 2013, https://doi.org/10.3389/fbuil.2018.00016
- Critical Ground Motion for Resilient Building Design Considering Uncertainty of Fault Rupture Slip vol.4, pp.None, 2013, https://doi.org/10.3389/fbuil.2018.00064
- Finite Difference Method-Based Critical Ground Motion and Robustness Evaluation for Long-Period Building Structures Under Uncertainty in Fault Rupture vol.5, pp.None, 2013, https://doi.org/10.3389/fbuil.2019.00002
- Simultaneous Approach to Critical Fault Rupture Slip Distribution and Optimal Damper Placement for Resilient Building Design vol.5, pp.None, 2013, https://doi.org/10.3389/fbuil.2019.00126
- Optimum design of viscous dampers to prevent pounding of adjacent structures vol.16, pp.4, 2013, https://doi.org/10.12989/eas.2019.16.4.437
- The effect of base isolation and tuned mass dampers on the seismic response of RC high-rise buildings considering soil-structure interaction vol.17, pp.4, 2013, https://doi.org/10.12989/eas.2019.17.4.425
- Smart Seismic Control System for High-Rise Buildings Using Large-Stroke Viscous Dampers Through Connection to Strong-Back Core Frame vol.6, pp.None, 2013, https://doi.org/10.3389/fbuil.2020.00029
- Seismic retrofit of steel buildings using external resistant RC walls and friction dampers vol.76, pp.6, 2020, https://doi.org/10.12989/sem.2020.76.6.823
- A Simple Critical Response Evaluation Method for Base-Isolation Building-Connection Hybrid System Under Double Impulse as Representative of Near-Fault Ground Motion vol.7, pp.None, 2013, https://doi.org/10.3389/fbuil.2021.790584
- Seismic Resistance and Parametric Study of Building under Control of Impulsive Semi-Active Mass Damper vol.11, pp.6, 2013, https://doi.org/10.3390/app11062468