DOI QR코드

DOI QR Code

Surface temperatures of public buildings, built in 1880, 1970 and 2002, in Northern Greece

  • Kosmopoulos, P. (Laboratory of Environmental and Energy Efficient Design of Buildings and Settlements, Department of Environmental Engineering, Democritus University of Thrace) ;
  • Kantzioura, A. (Laboratory of Environmental and Energy Efficient Design of Buildings and Settlements, Department of Environmental Engineering, Democritus University of Thrace)
  • Received : 2012.11.13
  • Accepted : 2013.04.15
  • Published : 2013.03.25

Abstract

The purpose of this paper is to investigate the surface temperatures of the shelter of three public buildings in the city of Xanthi, in northern Greece. The buildings were built in different time periods and consequently they have different technical characteristics. Respectively, we survey the three following buildings that have been built in 1880 (Municipality Hall of Xanthi), in 1970 (Municipality Amphitheatre) and in 2002 (Bank offices building). Data have been gathered by the use of thermal camera and the survey has been conducted from January up to July. The data gathered regard measurements of the surface temperature of the exterior walls of the shelters, both inside and outside. The study aims at the evaluation of the thermal behavior of the shelter of buildings, which built in different time and under different regulations. The gathered data of the surface temperatures compare the different thermal behavior of the shelter. The analysis of the results and diagrams show that the thick masonry of the traditional Municipality Hall offers an insulation that is adequate. The building of 1970, which was constructed with the previous buildings regulation, has thermal losses due to inadequate insulation. The new building of 2002 has low thermal losses.

Keywords

References

  1. Caccaveli, D. and Gugerli, H. (2002), "TOBUS-a European diagnosis and decision-making tool for office building upgrading", Energy Build., 34(2), 113-119. https://doi.org/10.1016/S0378-7788(01)00100-1
  2. Dimoudi, A. and Tompa, C. (2008), "Energy and environmental indicators related to construction of office buildings", Resour. Conserv. Recy. , 53(1-2), 86-95. https://doi.org/10.1016/j.resconrec.2008.09.008
  3. Gonzalez, A.B.R, Diaza, J.J.V., Caamanoa, A.J. and Wilbya, M.R. (2011), "Towards a universal energy efficiency index for buildings", Energy Build., 43( 4), 980-987. https://doi.org/10.1016/j.enbuild.2010.12.023
  4. Kosmopoulos, P. (Ed.) (2008), Buildings, Energy and Environment, Thessaloniki, University Studio Press.
  5. Spyropoulos, G. and Balaras, K. (2011), "Energy consumption and the potential of energy savings in Hellenic office buildings used as bank branches-A case study", Energy Baild., 43(4), 770-778. https://doi.org/10.1016/j.enbuild.2010.12.015