초록

Optimal sensor placement (OSP) technique plays a key role in the structural health monitoring (SHM) of large-scale structures. According to the mathematical background and implicit assumptions made in the triaxial effective independence (EfI) method, this paper presents a novel multi-dimensional OSP method for the Canton Tower focusing on application demands. In contrast to existing methods, the presented method renders the corresponding target mode shape partitions as linearly independent as possible and, at the same time, maintains the stability of the modal matrix in the iteration process. The modal assurance criterion (MAC), determinant of the Fisher Information Matrix (FIM) and condition number of the FIM have been taken as the optimal criteria, respectively, to demonstrate the feasibility and effectiveness of the proposed method. Numerical investigations suggest that the proposed method outperforms the original EfI method in all instances as expected, which is looked forward to be even more pronounced should it be used for other multi-dimensional optimization problems.

키워드

참고문헌

  1. ANSYS, ANSYS, Inc. Canonsburg, PA (USA), http://www.ansys.com.
  2. Coote, J.E., Lieven, N.A.J. and Skingle, G.W. (2005), "Sensor placement optimization for modal testing of a helicopter fuselage", Proceedings of the 24th International Modal Analysis Conference (IMAC), Orlando, Fl., USA.
  3. Fedorov, V.V. (1972), Theory of optimal experiments, New York, Academic Press.
  4. Friswell, M.I., Garvey, S.D. and Penny, J.E.T. (1995), "Model reduction using dynamic and iterated IRS techniques", J. Sound Vib., 186(2), 311-323. https://doi.org/10.1006/jsvi.1995.0451
  5. Golub, G.H. and Van, L.C.F. (1996), Matrix computations, 3rd Ed., Baltimore: Johns Hopkins University Press.
  6. Heo, G., Wang, M.L. and Satpathi, D. (1997), "Optimal transducer placement for health monitoring of long span bridge", Soil Dyn. Earthq. Eng., 16(7-8), 495-502. https://doi.org/10.1016/S0267-7261(97)00010-9
  7. Housner, G.W., Bergman, L.A., Caughey, T.K., Chassiakos, A.G., Claus, R.O., Masri, S.F., Soong, T.T., Spencer, B.F. and Yao, J.T.P. (1997), "Structural control: past, present, and future", J. Eng. Mech. - ASCE, 123(9), 897-971. https://doi.org/10.1061/(ASCE)0733-9399(1997)123:9(897)
  8. Kammer, D.C. (1991), "Sensor placement for on-orbit modal identification and correlation of large space structures", J. Guid. Control Dynam., 14(2), 251-259. https://doi.org/10.2514/3.20635
  9. Kammer, D.C. (2005), "Sensor set expansion for modal vibration testing", Mech. Syst. Signal Pr., 19(4), 700-713. https://doi.org/10.1016/j.ymssp.2004.06.003
  10. Kammer, D.C. and Tinker M.L. (2004), "Optimal placement of triaxial accelerometers for modal vibration tests", Mech. Syst. Signal Pr., 18(1), 29-41. https://doi.org/10.1016/S0888-3270(03)00017-7
  11. Kammer, D.C. and Yao, L. (1994), "Enhancement of on-orbit modal identification of large space structures through sensor placement", J. Sound Vib., 171(1), 119-140. https://doi.org/10.1006/jsvi.1994.1107
  12. Li, D.S., Li, H.N. and Fritzec, C.P. (2007), "The connection between effective independence and modal kinetic energy methods for sensor placement", J. Sound Vib., 305(4-5), 945-955. https://doi.org/10.1016/j.jsv.2007.05.004
  13. Li, D.S., Li, H.N. and Fritzec, C.P. (2009), "A note on fast computation of effective independence through QR downdating for sensor placement", Mech. Syst. Signal Pr., 23(4), 1160-1168. https://doi.org/10.1016/j.ymssp.2008.09.007
  14. Lin, W., Ni, Y.Q. Xia, Y. and Chen, W. H. (2010), "Field measurement data and a reduced order finite element model for Task I of the SHM benchmark problem for high rise structures", Proceedings of the 5th World Conference on Structural Control and Monitoring, Tokyo, Japan.
  15. Meo, M. and Zumpano, G. (2005), "On the optimal sensor placement techniques for a bridge structure", Eng. Struct., 27(10), 1488-1497. https://doi.org/10.1016/j.engstruct.2005.03.015
  16. Ni, Y.Q., Xia, Y., Liao, W.Y. and Ko, J.M. (2009), "Technology innovation in developing the structural health monitoring system for Guangzhou New TV Tower", Struct Health Monit., 16(1), 73-98. https://doi.org/10.1002/stc.303
  17. Park, Y.S. and Kim, H.B. (1996), "Sensor placement guide for model comparison and improvement", Proceedings of the 14th International Modal Analysis Conference (IMAC), Dearborn, Mi., USA.
  18. Wang, X.L., Qu, W.L. and Liu, H. (2007), "Finite element analysis on dynamic characteristics of super high tower in Guangzhou", J. Wuhan Univ. Technol., 29(1), 142-144. https://doi.org/10.3321/j.issn:1671-4431.2007.01.040
  19. Yi, T.H., Li, H.N. and Gu, M. (2011), "A new method for optimal selection of sensor location on a high-rise building using simplified finite element model", Struct. Eng. Mech., 37(6), 671-684. https://doi.org/10.12989/sem.2011.37.6.671
  20. Yi, T.H., Li, H.N. and Gu, M. (2011), "Optimal sensor placement for health monitoring of high-rise structure based on genetic algorithm", Math. Probl. Eng., Article ID 395101, 1-11.
  21. Yi, T.H., Li, H.N. and Gu, M. (2011), "Optimal sensor placement for structural health monitoring based on multiple optimization strategies", Struct. Des. Tall Spec., 20(7), 881-900. https://doi.org/10.1002/tal.712

피인용 문헌

  1. Optimal layout of long-gauge sensors for deformation distribution identification vol.18, pp.3, 2016, https://doi.org/10.12989/sss.2016.18.3.389
  2. Reviews on innovations and applications in structural health monitoring for infrastructures vol.1, pp.1, 2014, https://doi.org/10.12989/smm.2014.1.1.001
  3. Application of model reduction technique and structural subsection technique on optimal sensor placement of truss structures vol.15, pp.2, 2015, https://doi.org/10.12989/sss.2015.15.2.355
  4. Multiaxial sensor placement optimization in structural health monitoring using distributed wolf algorithm vol.23, pp.4, 2016, https://doi.org/10.1002/stc.1806
  5. Data fusion based improved Kalman filter with unknown inputs and without collocated acceleration measurements vol.18, pp.3, 2016, https://doi.org/10.12989/sss.2016.18.3.375
  6. Reproduction of vibration patterns of elastic structures by block-wise modal expansion method (BMEM) vol.18, pp.4, 2016, https://doi.org/10.12989/sss.2016.18.4.819
  7. Sensor optimization using a genetic algorithm for structural health monitoring in harsh environments vol.6, pp.3, 2016, https://doi.org/10.1007/s13349-016-0170-y
  8. Optimal placement of triaxial sensors for modal identification using hierarchic wolf algorithm vol.24, pp.8, 2017, https://doi.org/10.1002/stc.1958
  9. An Improved Genetic Algorithm for Optimal Sensor Placement in Space Structures Damage Detection vol.29, pp.3, 2013, https://doi.org/10.1260/0266-3511.29.3.121
  10. Monitoring of wind effects on a wind-sensitive hybrid structure with single-layer cable-net curtain walls under Typhoon Muifa vol.44, pp.None, 2021, https://doi.org/10.1016/j.jobe.2021.102960