참고문헌
- ABCB (1996), "Building Code of Australian", Australian Building Codes Board, Australia.
- BIA (1992), New Zealand Building Code Handbook and Approved Documents, Building Industry Authority, Wellington, New Zealand.
- British Standard (1987), "Fire tests on building materials and structures-part22", BS 476-22, British Standard Institution, London, UK.
- BSI (2002), Eurocode 1: "Actions on structures. Part 1-2: General actions - Actions on structures exposed to fire", BS EN 1991-1-2, European Standard, London, UK.
- Buchanan, A.H. (2001a), Fire Engineering Design Guide.
- Buchanan, A.H. (2001b), Structural design for fire safety, John Willy & Sons.
- Carden, L.P. and Itani, A.M. (2007), "Performance of an unprotected steel structure subjected to repeated fire at a firefighter training facility", Fire Safety J., 42(2), 81-90. https://doi.org/10.1016/j.firesaf.2006.06.009
- CNISK, MNTKS, BNIIPO (1996), "Elements of building constructions, fire - Resistance test methods (General Requirement)", GOST-30247-94, IPK.
- Department of Building Housing (2011), "Compliance Document for New Zealand Building Coode Clauses C1,C2,C3,C4 Fire Safety", New Zealand Government, 39-41.
- Dwaikat, M.M.S. and Kodur, V.K.R. (2011), "A performance based methodology for fire design of restrained steel beams", J. Construct. Steel Res., 67(3), 510-524. https://doi.org/10.1016/j.jcsr.2010.09.004
- GOST 30247.0 (1994), "Elements of building constructions, Fire-resistance test methods: General requirements", Interstate Scientific and Technical Commission on Standardization.
- GOST 30247.1 (1994), "Elements of building constructions, Fire-resistance test methods: Loadbearing and separating elements", Interstate Scientific and Technical Commission on Standardization.
- HMSO (1985), "The Building Regulations 1985", London, UK.
- IFCI (2000), "International Building Code", International Fire Code Institute, USA.
- Iqbal, S. and Harichandran, R.S. (2011), "Capacity reduction and fire load factors for LRFD of steel columns exposed to fire", Fire Safety J., 46(6), 234-242. https://doi.org/10.1016/j.firesaf.2011.02.005
- ISO (1999), "Fire resistance tests-Elements of building construction-part 1: General requirements", ISO 834-1, International Organization for Standardization, Switzerland.
- Kim, H.J., Kim, H.Y., Lee, J.S. and Cho, B.H. (2009a), "An analytical study on optimal shape condition of modular beam using fireproof board", J. Architect. Inst. Korea (Struct. & Construct.), 25(7), 3-12.
- Kim, H.Y., Lee, J.S., Yoo, Y.H., Cho, B.H. and Kim, H.J. (2009b), "A study on the fire experiment of medical modular block for the structure behavior and deformation under fire load condition", J. Architect. Inst. Korea (Struct. & Construct.), 25(12), 21-30.
- Korean agency for technology and Standards (2005), KS F 2257-1, "Methods of fire resistance test for elements of building construction-General requirements", Korean Standards Association.
- Korea Institute of Construction Technology (2004), Development of Fireproof Design Technology for the Architectural Buildings, Vol. 1, Ministry of Land, Transport, and Maritime Affairs, 97-99.
- Kwon, I.K. (2002), "State of the Art on the Fire Resistance of Steel Structures and Experimental Study on Section Factors in Korea", SFPE, 4th International Conference on Performance-Based Codes and Fire Safety Design Methods, Melbourne, Australia, March.
- Kwon, I.K. (2005), "Evaluation of fire resistance performance of load-bearing elements made up of light gauge steels", 8th International Conference on Steel, Space and Composition Structures, Malaysia.
- Lawson, R.M., Mullett, D.L. and Rackham, J.W. (1997), "Design of asymmetric 'Slimflor' beams using deep composite decking", The Steel Construction Institute, Berkshire, UK 175.
- Lee, J.S., Kim, H.Y., Cho, B.H., Kim, H.J. and Kim, G.D. (2008), "Fire resistance system of MCO beam using fireproof board", J. Architect. Inst. Korea (Struct. & Construct.), 24(11), 93-100.
- NPB 233-96 (1996), "Full Scale Fire Test Methods for Buildings", NPB Fire Safety Regulations.
- Park, S.Y., Kim, H.J., Kim, H.Y. and Hong, K.P. (2010), "Fire resistance of the Korean asymmetric slim floor beam depending on load ratio", J. Asian Architect. Build. Eng., 10(2), 413-420.
- Proe, D.J. and Bennetts, I.D. (1994), "Real fire tests in 380 Collins street office enclosure", BHP Research, BHPR/PPA/R/94/SG021A, Melbourne, Australia.
- SBBHP (1994), "Building Regulations 1994", Swedish Board of Building, Housing and Planning, Sweden.
- SNIP 21-01-97 (1997), "Fire Safety of Buildings and Structures, Standards and Regulations", Construction Codes and Regulations.
- Steel Construction Industry Forum (1991), "Investigation of Broadgate phase 8 fire", The Steel Construction Institute.
- Sun, R.R., Huang, Z.H. and Burgess, I.W. (2012), "The collapse behaviour of braced steel frames exposed to fire", J. Construct. Steel Res, 72, 130-142. https://doi.org/10.1016/j.jcsr.2011.11.008
- Thomas, I.R., Bennetts, I.D., Dayawansa, P., Proe, D.J. and Lewis, R.R. (1992), Fire Tests of the 140 William Street Office Building, BHP Research, BHPR/ENG/R/92 /043/SG2C, Melbourne Australia.
- Wald, F., Simoes da Silva, L., Moore, D.B., Lennon, T., Chladna, M., Santiago, A., Benes, M. and Borges, L. (2006), "Experimental behaviour of a steel structure under natural fire", Fire Safety J., 41(7), 509-522. https://doi.org/10.1016/j.firesaf.2006.05.006
- Wald, F., Sokol, Z., and Moore, D. (2009), "Horizontal forces in steel structures tested in fire", J. Construct. Steel Res., 65(8-9), 1896-1903. https://doi.org/10.1016/j.jcsr.2009.04.020
피인용 문헌
- Analytical and numerical studies on steel columns with novel connections in modular construction vol.17, pp.4, 2017, https://doi.org/10.1007/s13296-017-1226-5
- Development of an Efficient Steel Beam Section for Modular Construction Based on Six-Sigma vol.2016, 2016, https://doi.org/10.1155/2016/9687078
- A-State-Of-The-Art review on modular building connections vol.34, pp.None, 2021, https://doi.org/10.1016/j.istruc.2021.08.114