DOI QR코드

DOI QR Code

A Study on Section Properties of Partially Concrete-Filled New Type Composite Beam

부분매입형 신형상 합성보의 단면성능에 관한 연구

  • Yoon, Myung-Ho (Department of Architectural Engineering, Kongju National University) ;
  • Lee, Yoon-Hee (Department of Architectural Engineering, Kongju National University) ;
  • Lee, Ye-Seul (Department of Architectural Engineering, Kongju National University)
  • Received : 2013.09.06
  • Accepted : 2013.09.23
  • Published : 2013.09.30

Abstract

The demand for the structural system of reduction of story height increases because buildings are getting higher. The existing structural systems are not efficiency. Thus, it is hard to reduce the story height and existing methods cannot secure economics as expected. This study aims at developing the partially concrete-filled new type composite beam, which can efficiently resist against the end negative moment and central positive moment, also reduce deflection of beams. Through case studies on loading of concentrated load and uniformly distributed load to fixed beam, we could find the most efficient ratio of moment of inertia and the ratio ${\alpha}$(end beam length to span). The gap space between middle and end beam can be used as facilities installation, consequently the suggested Omega beam system is expected to get the effect of reduction in story height as well as reduction of quantity.

Keywords

References

  1. ASCE Standards (1992), Standard for the Structural Design : Composite Slabs, ANSI/ASCE3-91.
  2. Charles W. Roeder (1985), Point Loads on Composite Deck-Reinforced slabs.
  3. Erik Stefan Bernard, Russell Q. Bridge, Gregory J. Hancock (1993), Tests of Profiled Decks with V-Stiffeners.
  4. Max L. Porter (1995), Analysis of Two-way Action Composite.
  5. Mullet, D. L. (1998), Composite floor system, Steel construction institute.
  6. Robert E. Abendroth, Max L. Porter, Fatigue Behavior of Composite Metal Deck Slabs, 1989.
  7. Steel Deck institute (1997), Composite deck designhandbook, March,
  8. Yoon, M. H. (2006), Analysis and evaluation of Low Beam Type Steel-Concrete Composite Floor System, Final report to RIST, SnC Lab, Kongju Nat'l Univ.
  9. Yoon, M. H. and Lee, Y. H. (2011), "A study on Optimum Section of New Type Steel-Concrete Composite Beam," Korean Society for Advanced Composite Structures.

Cited by

  1. The Flexible Capacity Evaluation about Composite-stage of Semi Slim AU Composite Beam for Saving Story Height vol.9, pp.1, 2018, https://doi.org/10.11004/kosacs.2018.9.1.017
  2. 춤이 작은 신형상 고성능 하이브리드 합성보의 휨성능 평가 vol.28, pp.3, 2016, https://doi.org/10.7781/kjoss.2016.28.3.151
  3. Flexural Strength of Filled Composite Beams with Embossing Webs vol.31, pp.3, 2013, https://doi.org/10.7781/kjoss.2019.31.3.189