DOI QR코드

DOI QR Code

Temporal Characteristics of Volatile Organic Compounds in Newly-Constructed Residential Buildings: Concentration and Source

  • Shin, Seung-Ho (Department of Environmental Engineering, Kyungpook National University) ;
  • Jo, Wan-Kuen (Department of Environmental Engineering, Kyungpook National University)
  • Received : 2013.01.26
  • Accepted : 2013.05.09
  • Published : 2013.09.30

Abstract

The present study was designed to examine the concentrations, emission rates, and source characteristics of a variety of volatile organic compounds (VOCs) in 30 newly-constructed apartment buildings by measuring indoor and outdoor VOC concentrations over a 2-year period. For comparison, seven villa-type houses were also surveyed for indoor and outdoor VOC concentrations over a 3-month period. Indoor and outdoor air samples were collected on Tenax-TA adsorbent and analyzed using a gas chromatograph (GC)/mass spectrometer system or a GC/flame ionization detector system coupled to a thermal desorption system. The long-term change in indoor VOC concentrations depended on the type of VOCs. Generally, aromatic (except for naphthalene), aliphatic, and terpene compounds exhibited a gradual deceasing trend over the 2-year follow-up period. However, the indoor concentrations of the six halogenated VOCs did not significantly vary with time changes. Similar to these halogenated VOCs, the indoor naphthalene concentrations did not vary significantly with time changes over the 2-year period. Unlike the halogenated VOCs, the indoor naphthalene concentrations were much higher than the outdoor concentrations. The indoor concentrations of aliphatic and aromatic compounds were higher for the villa-type houses when compared to those of apartment buildings. In addition, four source groups (floor coverings and interior painting, household products, wood paneling and furniture, moth repellents) and three source groups (floor coverings and interior painting, household products, and moth repellents) were considered as potential VOC sources inside apartment buildings for the first- and second-year post-occupancy stages, respectively.

Keywords

References

  1. Hodgson AT, Rudd AF, Beal D, Chandra S. Volatile organic compound concentrations and emission rates in new manufactured and site-built houses. Indoor Air 2000;10:178-192. https://doi.org/10.1034/j.1600-0668.2000.010003178.x
  2. Jarnstrom H, Saarela K, Kalliokoski P, Pasanen AL. Reference values for indoor air pollutant concentrations in new, residential buildings in Finland. Atmos. Environ. 2006;40:7178-7191. https://doi.org/10.1016/j.atmosenv.2006.06.021
  3. Park JS, Ikeda K. Variations of formaldehyde and VOC levels during 3 years in new and older homes. Indoor Air 2006;16:129-135. https://doi.org/10.1111/j.1600-0668.2005.00408.x
  4. Lim S, Lee K, Seo S, Jang S. Impact of regulation on indoor volatile organic compounds in new unoccupied apartment in Korea. Atmos. Environ. 2011;45:1994-2000. https://doi.org/10.1016/j.atmosenv.2011.01.020
  5. Smith GB, Aguilar JL, Gentle AR, Chen D. Multi-parameter sensitivity analysis: a design methodology applied to energy efficiency in temperate climate houses. Energy Build. 2012;55:668-673. https://doi.org/10.1016/j.enbuild.2012.09.007
  6. Chino S, Kato S, Seo J, Ataka Y. Study on emission of decomposed chemicals of esters contained in PVC flooring and adhesive. Build. Environ. 2009;44:1337-1342. https://doi.org/10.1016/j.buildenv.2008.07.003
  7. Nicolle J, Desauziers V, Mocho P, Ramalho O. Optimization of FLEC-SPME for field passive sampling of VOCs emitted from solid building materials. Talanta 2009;80:730-737. https://doi.org/10.1016/j.talanta.2009.07.063
  8. Shinohara N, Kai Y, Mizukoshi A, et al. On-site passive flux sampler measurement of emission rates of carbonyls and VOCs from multiple indoor sources. Build. Environ. 2009;44:859-863. https://doi.org/10.1016/j.buildenv.2008.06.007
  9. Hutter HP, Moshammer H, Wallner P, Damberger B, Tappler P, Kundi M. Health complaints and annoyances after moving into a new office building: a multidisciplinary approach including analysis of questionnaires, air and house dust samples. Int. J. Hyg. Environ. Health 2006;209:65-68. https://doi.org/10.1016/j.ijheh.2005.08.010
  10. Mendell MJ. Indoor residential chemical emissions as risk factors for respiratory and allergic effects in children: a review. Indoor Air 2007;17:259-277. https://doi.org/10.1111/j.1600-0668.2007.00478.x
  11. Rumchev K, Brown H, Spickett J. Volatile organic compounds: do they present a risk to our health? Rev. Environ. Health 2007;22:39-55.
  12. Sarigiannis DA, Karakitsios SP, Gotti A, Liakos IL, Katsoyiannis A. Exposure to major volatile organic compounds and carbonyls in European indoor environments and associated health risk. Environ. Int. 2011;37:743-765. https://doi.org/10.1016/j.envint.2011.01.005
  13. World Health Organization, Regional Office for Europe. Air quality guidelines for Europe. Copenhagen: World Health Organization; 2000.
  14. International Agency for Research on Cancer. Agents classified by the IARC monographs, volumes 1-108 [Internet]. Lyon: International Agency for Research on Cancer; c2013 [cited 2013 Jul 15]. Available from: http://monographs.iarc. fr/ENG/Classification/ClassificationsAlphaOrder.pdf.
  15. Ramirez N, Cuadras A, Rovira E, Borrull F, Marce RM. Chronic risk assessment of exposure to volatile organic compounds in the atmosphere near the largest Mediterranean industrial site. Environ. Int. 2012;39:200-209. https://doi.org/10.1016/j.envint.2011.11.002
  16. Su FC, Jia C, Batterman S. Extreme value analyses of VOC exposures and risks: a comparison of RIOPA and NHANES datasets. Atmos. Environ. 2012;62:97-106. https://doi.org/10.1016/j.atmosenv.2012.06.038
  17. Jia C, D'Souza J, Batterman S. Distributions of personal VOC exposures: a population-based analysis. Environ. Int. 2008;34:922-931. https://doi.org/10.1016/j.envint.2008.02.002
  18. Brown SK. Volatile organic pollutants in new and established buildings in Melbourne, Australia. Indoor Air 2002;12:55-63. https://doi.org/10.1034/j.1600-0668.2002.120107.x
  19. Jarnstrom H, Saarela K, Kalliokoski P, Pasanen AL. Reference values for structure emissions measured on site in new residential buildings in Finland. Atmos. Environ. 2007;41:2290-2302. https://doi.org/10.1016/j.atmosenv.2006.11.033
  20. Han KH, Zhang JS, Wargocki P, Knudsen HN, Varshney PK, Guo B. Model-based approach to account for the variation of primary VOC emissions over time in the identification of indoor VOC sources. Build. Environ. 2012;57:403-416. https://doi.org/10.1016/j.buildenv.2012.06.011
  21. California Environmental Protection Agency, Office of Environmental Health Hazard Assessment. Air toxics hot spots program risk assessment guidelines. Part II: Technical support document for describing available cancer potency factors. Sacramento: California Environmental Protection Agency, Office of Environmental Health Hazard Assessment; 2005.
  22. US Environmental Protection Agency. Integrated Risk Information System (IRIS) [Internet]. Washington: US Environmental Protection Agency; c2013 [cited 2013 Jul 15]. Available from: http://www.epa.gov/IRIS/index.html.
  23. Brinkman GL, Milford JB, Schauer JJ, Shafer MM, Hannigan MP. Source identification of personal exposure to fine particulate matter using organic tracers. Atmos. Environ. 2009;43:1972-1981. https://doi.org/10.1016/j.atmosenv.2009.01.023
  24. Leuchner M, Rappengluck B. VOC source-receptor relationships in Houston during TexAQS-II. Atmos. Environ. 2010;44:4056-4067. https://doi.org/10.1016/j.atmosenv.2009.02.029
  25. Perez-Rial D, Lopez-Mahia P, Tauler R. Investigation of the source composition and temporal distribution of volatile organic compounds (VOCs) in a suburban area of the northwest of Spain using chemometric methods. Atmos. Environ. 2010;44:5122-5132. https://doi.org/10.1016/j.atmosenv.2010.09.005
  26. Chiriac R, De Araujos Morais J, Carre J, Bayard R, Chovelon JM, Gourdon R. Study of the VOC emissions from a municipal solid waste storage pilot-scale cell: comparison with biogases from municipal waste landfill site. Waste Manag. 2011;31:2294-2301. https://doi.org/10.1016/j.wasman.2011.06.009
  27. Vega E, Sanchez-Reyna G, Mora-Perdomo V, et al. Air quality assessment in a highly industrialized area of Mexico: concentrations and sources of volatile organic compounds. Fuel 2011;90:3509-3520. https://doi.org/10.1016/j.fuel.2011.03.050
  28. Jo WK, Chun HH, Lee SO. Evaluation of atmospheric volatile organic compound characteristics in specific areas in Korea using long-term monitoring data. Environ. Eng. Res. 2012;17:103-110. https://doi.org/10.4491/eer.2012.17.2.103
  29. Wang J, Jin L, Gao J, et al. Investigation of speciated VOC in gasoline vehicular exhaust under ECE and EUDC test cycles. Sci. Total Environ. 2013;445-446:110-116. https://doi.org/10.1016/j.scitotenv.2012.12.044
  30. Li A, Schoonover TM, Zou Q, et al. Polycyclic aromatic hydrocarbons in residential air of ten Chicago area homes: concentrations and influencing factors. Atmos. Environ. 2005;39:3491-3501. https://doi.org/10.1016/j.atmosenv.2005.02.029
  31. Lu R, Wu J, Turco RP, et al. Naphthalene distributions and human exposure in Southern California. Atmos. Environ. 2005;39:489-507. https://doi.org/10.1016/j.atmosenv.2004.09.045
  32. Zuraimi MS, Tham KW, Sekhar SC. A study on the identification and quantification of sources of VOCs in 5 airconditioned Singapore office buildings. Build. Environ. 2004;39:165-177. https://doi.org/10.1016/j.buildenv.2003.08.013
  33. Zhu J, Cao XL, Beauchamp R. Determination of 2-butoxyethanol emissions from selected consumer products and its application in assessment of inhalation exposure associated with cleaning tasks. Environ. Int. 2001;26:589-597. https://doi.org/10.1016/S0160-4120(01)00046-0
  34. Kwon KD, Jo WK, Lim HJ, Jeong WS. Characterization of emissions composition for selected household products available in Korea. J. Hazard. Mater. 2007;148:192-198. https://doi.org/10.1016/j.jhazmat.2007.02.025
  35. Theloke J, Friedrich R. Compilation of a database on the composition of anthropogenic VOC emissions for atmospheric modeling in Europe. Atmos. Environ. 2007;41:4148-4160. https://doi.org/10.1016/j.atmosenv.2006.12.026
  36. Wilke O, Jann O, Brodner D. VOC- and SVOC-emissions from adhesives, floor coverings and complete floor structures. Indoor Air 2004;14 Suppl 8:98-107. https://doi.org/10.1111/j.1600-0668.2004.00314.x
  37. Yuan B, Shao M, Lu S, Wang B. Source profiles of volatile organic compounds associated with solvent use in Beijing, China. Atmos. Environ. 2010;44:1919-1926. https://doi.org/10.1016/j.atmosenv.2010.02.014
  38. Guo H. Source apportionment of volatile organic compounds in Hong Kong homes. Build. Environ. 2011;46:2280-2286. https://doi.org/10.1016/j.buildenv.2011.05.008

Cited by

  1. Environmental Engineering Research in September 2013 pp.2005-968X, 2013, https://doi.org/10.4491/eer.2013.18.3.115
  2. Environmental Engineering Research in December 2013 pp.2005-968X, 2013, https://doi.org/10.4491/eer.2013.18.4.209