DOI QR코드

DOI QR Code

Fourier-Based PLL Applied for Selective Harmonic Estimation in Electric Power Systems

  • Santos, Claudio H.G. (Dept. of Electronic Eng., Federal University of Ouro Preto (UFOP)) ;
  • Ferreira, Reginaldo V. (Federal Institute of Minas Gerais (IFMG)) ;
  • Silva, Sidelmo Magalhaes (Dept. of Electrical Eng., Federal University of Minas Gerais (UFMG)) ;
  • Cardoso Filho, Braz J. (Dept. of Electrical Eng., Federal University of Minas Gerais (UFMG))
  • Received : 2012.04.27
  • Published : 2013.09.20

Abstract

In this paper, the Fourier-based PLL (Phase-locked Loop) is introduced with a new structure, capable of selective harmonic detection in single and three-phase systems. The application of the FB-PLL to harmonic detection is discussed and a new model applicable to three-phase systems is introduced. An analysis of the convergence of the FB-PLL based on a linear model is presented. Simulation and experimental results are included for performance analysis and to support the theoretical development. The decomposition of an input signal in its harmonic components using the Fourier theory is based on previous knowledge of the signal fundamental frequency, which cannot be easily implemented with input signals with varying frequencies or subjected to phase-angle jumps. In this scenario, the main contribution of this paper is the association of a phase-locked loop system, with a harmonic decomposition and reconstruction method, based on the well-established Fourier theory, to allow for the tracking of the fundamental component and desired harmonics from distorted input signals with a varying frequency, amplitude and phase-angle. The application of the proposed technique in three-phase systems is supported by results obtained under unbalanced and voltage sag conditions.

Keywords

References

  1. P. Mattavelli, "A closed-loop selective harmonic compensation for active filters," IEEE Trans. Ind. Appl., Vol. 37, No. 1, pp. 81-89, Jan./Feb. 2001. https://doi.org/10.1109/28.903130
  2. L. Asiminoaei, F. Blaabjerg, and S. Hansen, "Detection is key - harmonic detection methods for active power filter applications," IEEE Ind. Appl. Mag., Vol. 13, No. 4, pp. 22-33, Jul./Aug. 2007. https://doi.org/10.1109/MIA.2007.4283506
  3. D. Yazdani, A. Bakhshai, G. Joos, and M. Mojiri, "A real-time three-phase selective harmonic extraction approach for grid-connected converters," IEEE Trans. Ind. Electron., Vol. 56, No. 10, pp.4097-4106, Oct. 2009. https://doi.org/10.1109/TIE.2009.2024658
  4. S. Rechka, E. Ngandui, J. Xu, and P. Sicard, "A comparative study of harmonic detection algorithms for active filters and hybrid active filters," in Proc. PESC, Vol. 1, pp. 357-363, June, 2002.
  5. H.Akagi, Y.Kanazawa and A. Nabae, "Instantaneous reactive power compensators comprising switching devices without energy storage components," IEEE Trans. Ind. Appl., Vol. 1A-20, No. 3, pp.625-630, May/Jun., 1984.
  6. V. M. Moreno, M. Liserrre, A. Pigazo, and A. Dell'Aquila, "A comparative analysis of real-time algorithms for power signal decoposition in multiple synchronous reference frames," IEEE Trans. Power Electron., Vol. 22, No. 4, pp. 1280-1289, Jul. 2007. https://doi.org/10.1109/TPEL.2007.900484
  7. S.D. Round and D.M.E. Ingram, "An evaluation techniques for determining active filter compensating currents in unbalanced systems," in Proc. EPE Trondheim, pp. 4.767-4.772, Sep. 1997.
  8. C. H. G. Santos, S. M. Silva, B. J. C. Filho, "A fourier-based PLL for single-phase grid connected systems," in Proc. Energy Conversion Congress and Exposition (ECCE), 2010, pp. 2626-2632, Sep. 2010.
  9. A. V. Oppenheim and A. S. Willsky, Signals and Systems, Prentice Hall, 2nd Ed., chap. 4, New Delhi, 2009.
  10. P. Rodriguez, L. Sainz, and J. Bergas, "Synchronous double reference frame PLL applied to a unified power quality conditioner," in Proc. Harmonics and Quality of Power, pp. 614- 619, Vol. 2, Oct. 2002.
  11. P. Rodriguez, "Aportaciones a los acondicionadores activos de corriente en derivacion para redes trifasicas de cuatro hilos," Ph. D. Thesis, Universitat Politecnica de Catalunya, Barcelona, Jan. 2005.
  12. E. H. Watanabe, H. Akagi, and M. Aredes, "The P-Q theory for active filter control: some problems and solutions," Departament of Electrical and Electronic Engineering, Tokyo Institute of Technology, Revista Controle & Automacao, Vol. 15, No. 1, Jan./ Mar. 2004.
  13. R. M. Santos Filho, P. F. Seixas, P. C. Cortizo, L.A.B. Torres, A. F. Souza, "Comparison of three single-phase PLL algorithms for UPS applications," IEEE Trans. Ind. Electron., Vol. 55, p. 2923-2932, Aug. 2008. https://doi.org/10.1109/TIE.2008.924205
  14. D. Yazdani, A. Bakhshai, G. Joos, and M. Mojiri, "A real time three-phase selective harmonic extraction approach for grid connected converters," IEEE Trans. Ind. Electron., Vol. 56, No. 10, pp. 4097-4106, Oct. 2009. https://doi.org/10.1109/TIE.2009.2024658

Cited by

  1. Advanced SOGI-FLL Scheme Based on Fuzzy Logic for Single-Phase Grid-Connected Converters vol.14, pp.3, 2014, https://doi.org/10.6113/JPE.2014.14.3.598
  2. A Novel Fast Open-loop Phase Locking Scheme Based on Synchronous Reference Frame for Three-phase Non-ideal Power Grids vol.16, pp.4, 2016, https://doi.org/10.6113/JPE.2016.16.4.1513