References
- Chai, W. and Feng, M.Q. (1997), "Vibration control of super tall buildings subjected to wind loads", Int. J. Nonlinear Mech., 32(4), 657-668. https://doi.org/10.1016/S0020-7462(96)00094-7
- Cimellaro, G.P. (2007), "Simultaneous stiffness-damping optimization of structures with respect to acceleration, displacement and base shear", Eng. Struct., 29(11), 2853-2870. https://doi.org/10.1016/j.engstruct.2007.01.001
- Feng, M.Q. and Mita, A. (1995), "Vibration control of tall buildings using mega-sub configuration", J. Eng. Mech. - ASCE, 121(10), 1082-1087. https://doi.org/10.1061/(ASCE)0733-9399(1995)121:10(1082)
- Gao, X.Y. and He, R.Q. (2003), "Research on equivalent model of mega-structure", J. Univ. of Sci. Tech. of Suzhou, 16(2), 66-72.
- Kiu, W., Tong, M., Wu, Y. and Lee, G. (2004), "Optimized damping device configuration design of a steel frame structure based on building performance indices", Earthq. Spectra, 20(1), 67-89. https://doi.org/10.1193/1.1648334
- Li, Tao, Zhang, X.A. and Toi, Limazie (2011), "Viscous dampers installation arrangement and hysteresis curve characteristics research on the mega-sub controlled structure system", Appl. Mech. Mater., 71-78, 1687-1690. https://doi.org/10.4028/www.scientific.net/AMM.71-78.1687
- Li, Tao, Zhang, X.A. and Wang, Q.Q. (2011), "Control characteristics of mega-sub controlled structure system with friction damper under rare earthquake", Proceedings of the International Multiconference of Engineering and Computers Scientists 2011, Vol II, IMECS 2011, March 16 - 18, 2011, Hong Kong.
- Lian, Y.D., Zhang, X.A. and Cherry, S. (2007), "Damping characteristics of friction damped braced frame and its effectiveness in the mega-sub controlled structure system", Earthq. Eng. Eng. Vib., 6(2), 171-181. https://doi.org/10.1007/s11803-007-0732-4
- Liu, X.A., Zhang, X.A. and Wang, X.B. (2009), "Research on dynamic responses of MSCSS under horizontal seismic action", J. Yanshan Univ., 33(3), 254-257.
- Qin, Xiangjun and Zhang, X.A. (2009), "Vibration controlling characteristics of a new improved mega-sub controlled structure subjected to random wind load", Proceedings of the International MultiConference of Engineers and Computer Scientists 2009, Vol II IMECS 2009, March 18 - 20, 2009, Hong Kong.
- Qin, X.J., Zhang, X.A. and Sheldon, C. (2008), "Study on semi-active control of mega-sub controlled structure by MR damper subjected to random wind loads", Earthq. Eng. Eng. Vib., 7(3), 285-294 https://doi.org/10.1007/s11803-008-0838-3
- Takabatake, H. and Satoh, T. (2006), "A simplified analysis and vibration control to super-high-rise buildings", Struct. Des. Tall Spec. Build., 15(4), 363-390. https://doi.org/10.1002/tal.276
- Takewaki, I. (2009), Building control with passive dampers: optimal performance-based design for earthquakes, John Wiley & Sons (Asia), Singapore.
- Tsuji, M. and Nakamura, T. (1996), "Optimum viscous dampers for stiffness design of shear buildings", J. Struct. Des. Tall Build., 5(3), 217-234. https://doi.org/10.1002/(SICI)1099-1794(199609)5:3<217::AID-TAL70>3.0.CO;2-R
- Zhang, X.A., Qin, X.J., Cherry, S. and Lian, Y.D. (2009), "A new proposed passive mega-sub controlled structure and response control", J. Earthq. Eng., 13(2), 252-274. https://doi.org/10.1080/13632460802347422
- Zhang, X.A., Wang, Dong and Jiang, Jiesheng (2005), "The controlling mechanism and the controlling effectiveness of passive mega-sub-controlled frame subjected to random wind loads", J. Sound Vib., 283(3-5), 543-560. https://doi.org/10.1016/j.jsv.2004.04.038
Cited by
- Wind-induced vibration control of super-tall buildings using a new combined structural system vol.172, 2018, https://doi.org/10.1016/j.jweia.2017.10.029
- Floor acceleration control of super-tall buildings with vibration reduction substructures vol.26, pp.16, 2017, https://doi.org/10.1002/tal.1343
- Experimental investigation of mega-sub isolation structure vol.26, pp.16, 2017, https://doi.org/10.1002/tal.1360
- Optimization of response of a dynamic vibration absorber forming part of the main system by the fixed-point theory 2018, https://doi.org/10.1007/s12205-017-1237-y
- Seismic Performance Evaluations of Mega-Sub Isolation System vol.2016, 2016, https://doi.org/10.1155/2016/7031712
- Mechanism Analysis and Parameter Optimization of Mega-Sub-Isolation System vol.2016, 2016, https://doi.org/10.1155/2016/2605839
- Dynamic Reliability Analysis of Mega-Sub Isolation System Under Random Ground Motion vol.11, pp.None, 2013, https://doi.org/10.2174/1874149501711010822
- Seismic behavior of MSCSS based on story drift and failure path vol.18, pp.8, 2013, https://doi.org/10.1590/1679-78256787
- Investigations on a mega-sub isolation system under near-fault ground motions vol.24, pp.15, 2021, https://doi.org/10.1177/13694332211026227