Lateral Force Calibration of Colloidal Probe in Liquid Environment Using Reference Cantilever

기준 외팔보를 이용한 액체 환경에서 Colloidal Probe의 수평방향 힘 교정

  • Je, Youngwan (School of Mechanical Engineering, University of Ulsan) ;
  • Chung, Koo-Hyun (School of Mechanical Engineering, University of Ulsan)
  • Received : 2013.03.11
  • Accepted : 2013.04.09
  • Published : 2013.06.30

Abstract

There is an indispensable need for force calibration for quantitative nanoscale force measurement using atomic force microscopy. Calibrating the normal force is relatively straightforward, whereas doing so for the lateral force is often complicated because of the difficulty in determining the optical lever sensitivity. In particular, the lateral force calibration of a colloidal probe in a liquid environment often has a larger uncertainty as a result of the effects of the epoxy, the location of the colloidal particle on the cantilever, and a decrease in the quality factor. In this work, the lateral force of a colloidal probe using a reference cantilever with a known spring constant was calibrated in a liquid environment. By obtaining the spring constant and the lateral sensitivity at the equator of a spherical colloidal particle, the damage to the bottom surface of the colloidal particle could be eliminated. Further, it was shown that the effect of the contact stiffness on the determination of the lateral spring constant of the cantilever could be minimized. It was concluded that this method can be effectively used for the lateral force calibration of a colloidal probe in a liquid environment.

Keywords

References

  1. Binnig, G., Quate, C. F., and Gerber, C., "Atomic Force Microscope", Phys Rev Lett, Vol. 56, pp. 930- 933, 1986. https://doi.org/10.1103/PhysRevLett.56.930
  2. Mahaffy, R. E., Shih, C. K., MacKintosh, F. C., and Käs, J., "Scanning Probe-Based Frequency-Dependent Microrheology of Polymer Gels and Biological Cells", Phys Rev Lett, Vol. 85, pp. 880-883, 2000. https://doi.org/10.1103/PhysRevLett.85.880
  3. Chung, K. H., Bhadriraju, K., Spurlin, T. A., Cook, R. F., and Plant, A. L., "Nanomechanical Properties of Thin Films of Type I Collagen Fibrils", Langmuir, Vol. 26, pp. 3629-3636, 2010. https://doi.org/10.1021/la903073v
  4. Stan, G., Ciobanu, C. V., Parthangal, P. M., and Cook, R. F., "Diameter-Dependent Radial and Tangential Elastic Moduli of ZnO Nanowires", Nano Lett., Vol. 7, pp. 3691-3697, 2007. https://doi.org/10.1021/nl071986e
  5. Hutter, J. L. and Bechhoefer, J., "Calibration of Atomic-Force Microscope Tips", Rev. Sci. Instrum., Vol. 64, pp. 1868-1873, 1993. https://doi.org/10.1063/1.1143970
  6. Torii, A., Sasaki, M., Hane, K., and Okuma, S., "A Method for Determining the Spring Constant of Cantilevers for Atomic Force Microscopy", Meas Sci Technol, Vol. 7, pp. 179-184, 1996. https://doi.org/10.1088/0957-0233/7/2/010
  7. Gates, R. S. and Reitsma, M. G., "Precise Atomic Force Microscope Cantilever Spring Constant Calibration using a Reference Cantilever Array", Rev. Sci. Instrum., Vol. 78, pp. 086101, 2007. https://doi.org/10.1063/1.2764372
  8. Sader, J. E., Chon, J. W. M., and Mulvaney, P., "Calibration of Rectangular Atomic Force Microscope Cantilevers", Rev. Sci. Instrum., Vol. 70, pp. 3967- 3969, 1999. https://doi.org/10.1063/1.1150021
  9. Green, C. P., Lioe, H., Cleveland, J. P., Proksch, R., Mulvaney, P., and Sader, J. E., "Normal and Torsional Spring Constants of Atomic Force Microscope Cantilevers", Rev. Sci. Instrum., Vol. 75, pp. 1988- 1996, 2004. https://doi.org/10.1063/1.1753100
  10. Ravi, T. S., Marcus, R. B., and Liu, D., "Oxidation Sharpening of Silicon Tips", J. Vac. Sci. Technol. B, Vol. 9, pp. 2733-2737, 1991. https://doi.org/10.1116/1.585680
  11. Folch, A., Wrighton, M. S., and Schmidt, M. A., "Microfabrication of Oxidation-Sharpened Silicon Tips on Silicon Nitride Cantilevers for Atomic Force Microscopy", Microelectromechanical Systems, Journal Of, Vol. 6, pp. 303-306, 1997. https://doi.org/10.1109/84.650126
  12. Ducker, W. A., Senden, T. J., and Pashley, R. M., "Direct Measurement of Colloidal Forces using an Atomic Force Microscope", Nature, Vol. 353, pp. 239-241, 1991. https://doi.org/10.1038/353239a0
  13. Chung, K. H., Pratt, J. R., and Reitsma, M. G., "Lateral Force Calibration: Accurate Procedures for Colloidal Probe Friction Measurements in Atomic Force Microscopy", Langmuir, Vol. 26, pp. 1386-1394, 2010. https://doi.org/10.1021/la902488r
  14. Chung, K. H., Shaw, G. A., and Pratt, J. R., "Accurate Noncontact Calibration of Colloidal Probe Sensitivities in Atomic Force Microscopy", Rev. Sci. Instrum., Vol. 80, pp. 065107, 2009. https://doi.org/10.1063/1.3152335
  15. Sader, J. E. and Green, C. P., "In-Plane Deformation of Cantilever Plates with Applications to Lateral Force Microscopy", Rev. Sci. Instrum., Vol. 75, pp. 878-883, 2004. https://doi.org/10.1063/1.1667252
  16. Craig, V. S. J. and Neto, C., "In Situ Calibration of Colloid Probe Cantilevers in Force Microscopy: Hydrodynamic Drag on a Sphere Approaching a Wall", Langmuir, Vol. 17, pp. 6018-6022, 2001. https://doi.org/10.1021/la010424m
  17. Ryu, S. and Franck, C., "In Situ Hydrodynamic Lateral Force Calibration of AFM Colloidal Probes", Langmuir, Vol. 27, pp. 13390-13399, 2011. https://doi.org/10.1021/la201033e
  18. John R. Taylor. An Introduction Error Analysis: The Study of Uncertainties in Physical Measurements. Sausalito, Caifornia: University Science Books, 1996.
  19. Johnson KL. Contact Mechanics. : Cambridge University Press, 1985.
  20. Carpick, R. W., Ogletree, D. F., and Salmeron, M., "Lateral Stiffness: A New Nanomechanical Measurement for the Determination of Shear Strengths with Friction Force Microscopy", Appl. Phys. Lett., Vol. 70, pp. 1548-1550, 1997. https://doi.org/10.1063/1.118639