Abstract
An active power factor correction (PFC) circuit is presented which employs a newly proposed input voltage sensor-less control technique operated in continuous conduction mode (CCM) and critical conduction mode (CRM). The conventional PFC circuit with input voltage sensor-less control technique degrades the power factor (PF) under the light load condition due to DCM operation. In the proposed PFC circuit, the switching frequency is basically 70KHz in CCM operation. In light load condition, however, the PFC circuit operates in CRM and the switching frequency is increased up to 200KHz. So CCM/CRM operation of the PFC circuit alleviates the decreasing of the PF in light load condition. The proposed PFC controller IC has been implemented in a $0.35{\mu}m$ BCDMOS process and a 240W PFC prototype is built. Experimental results shows the PF of the proposed PFC circuit is improved up to 10% from the one employing the conventional CCM/DCM dual mode control technique. Also, the PF is improved up to 4% in the light load condition of the IEC 61000-3-2 Class D specifications.
본 논문에서는 입력전압을 감지하지 않는 전류연속/임계동작모드 active power factor correction(PFC) circuit을 제안하였다. 기존의 입력전압을 감지하지 않는 PFC circuit의 경우 출력전류가 낮은 경 부하 조건에서 DCM 동작을 수행하고, 이에 따라 PF가 감소하는 문제가 발생한다. 제안한 PFC circuit은 70KHz의 주파수로 CCM 동작을 수행하고, 경 부하 조건에서 최대 200KHz까지 스위칭 주파수가 가변되는 CRM 동작을 수행하도록 하였다. 이를 통해 경 부하 조건에서 PF가 감소하는 문제를 해결하였다. PFC controller IC는 $0.35{\mu}m$ BCDMOS 공정을 이용하여 제작하였으며, 240W급 PFC prototype을 제작하여 실험하였다. 제안한 PFC circuit은 기존의 PFC circcuit 대비 최대 10%의 역률이 향상되었고, IEC 61000-3-2 Class D 규격에 따른 경 부하 조건에서는 최대 4% 역률이 향상되었다.