개에서 심초음파 검사시 마취제가 일회심박출량에 미치는 영향과 ACT법의 적용가능성 평가

Evaluation of Influence of Anesthetics on Canine Stroke Volume and Feasibility of ACT Using Echocardiography

  • 박기태 (경상대학교 생명과학연구원) ;
  • 이은성 (경상대학교 생명과학연구원) ;
  • 정동인 (경상대학교 생명과학연구원) ;
  • 연성찬 (경상대학교 생명과학연구원) ;
  • 이희천 (경상대학교 생명과학연구원)
  • Park, Ki-Tae (Research Institute of Life Sciences, Gyeongsang National University) ;
  • Lee, Eun-Sung (Research Institute of Life Sciences, Gyeongsang National University) ;
  • Jung, Dong-In (Research Institute of Life Sciences, Gyeongsang National University) ;
  • Yeon, Seong-Chan (Research Institute of Life Sciences, Gyeongsang National University) ;
  • Lee, Hee-Chun (Research Institute of Life Sciences, Gyeongsang National University)
  • 심사 : 2013.06.07
  • 발행 : 2013.08.31

초록

Stroke volume (SV) is an important parameter for monitoring of a critically ill animal and is echocardiographically measured using the modified Simpson's method, automated contour tracking (ACT) method and left ventricular outflow method. The purpose of this study was to evaluate the effect of anesthesia (isoflurane) on the SV during echocardiographic examination and to evaluate the feasibility of ACT method for measuring the stroke volume without anesthesia (conscious state). Ten clinically healthy adult Beagle dogs (3 male and 7 female, weighing 6.6-10.8 kg, aged 2-3 years old) were enrolled. Our study found that the dogs anesthetized have a significantly lower SV, compared to the SV of dogs unanesthetized, regardless of methods measuring SV. In addition, in the dogs without anesthesia, the SV measured by ACT method was significantly lower than the other two methods. This result implies that the anesthesia may significantly lower the SV. Thus, the measurement of SV under anesthesia may not be adequate in veterinary field. Furthermore because the ACT method measured SV significantly lower than other two methods, this method may be inappropriate for measuring SV in even conscious dogs.

키워드

참고문헌

  1. Abbott JA, MacLean HN. Comparison of Doppler-derived peak aortic velocities obtained from subcostal and apical transducer sites in healthy dogs. Vet Radiol Ultrasound 2003; 44: 695-698. https://doi.org/10.1111/j.1740-8261.2003.tb00533.x
  2. Boon JA. Manual of veterinary echocardiography. Blackwell publishing 2006; 1: 1983-1985.
  3. Critchley LA, Peng ZY, Fok BS, Lee A, Phillips RA. Testing the reliability of a new ultrasonic cardiac output monitor, the USCOM, by using aortic flowprobes in anesthetized dogs. Anesth Analg 2005; 100: 748-753. https://doi.org/10.1213/01.ANE.0000144774.42408.05
  4. Eddie Clutton R. Anaesthetic complication, accidents and emergencies. In BASAVA Manual of Canine and Feline Anaesthesia and Analgesia (Seymour C, Duke-Novakovski T, editors). BSAVA 2007; 2: 317-320.
  5. Eddie Clutton R. Legal and ethical aspects of anaesthesia. In BASAVA Manual of Canine and Feline Anaesthesia and Analgesia (Seymour C, Duke-Novakovski T, editors). BSAVA 2007; 2: 1.
  6. Ehlers KC, Mylrea KC, Waterson CK, Calkins JM. Cardiac output measurements. A review of current techniques and research. Ann Biomed Eng 1986; 14: 219-239. https://doi.org/10.1007/BF02584272
  7. Gore JM, Goldberg RJ, Spodick DH, Alpert JS, Dalen JE. A community-wide assessment of the use of pulmonary artery catheters in patients with acute myocardial infarction. Chest 1987; 92: 721-7. https://doi.org/10.1378/chest.92.4.721
  8. Guyton AC. The Fick principle. In Circulatory Physiology: Cardiac output and its regulation, 2nd ed. Philadelphia: Saunders. 1973; 1: 21.
  9. Guyton AC, Hall JE. The heart. In Medical Physiology. Philadelphia: Saunders. 2002; 7: 171.
  10. Hergan K, Schuster A, Fruhwald J, Mair M, Burger R, Topker M. Comparison of left and right ventricular volume measurement using the Simpson's method and the area length method. Eur J Radiol 2008; 65: 270-278. https://doi.org/10.1016/j.ejrad.2007.03.031
  11. Hozumi T, Yoshida K, Yoshioka H, Yagi T, Akasaka T, Takasi T, Nishiura M, Watanabe M, Yoshikawa J. Echocardiographic estimation of left ventricular cavity area with a newly developed automated contour tracking method. J Am Soc Echocardiogr 1997; 10: 822-829. https://doi.org/10.1016/S0894-7317(97)70042-7
  12. Kienle RD, Thomas WP. Echocardiography. In Small animal diagnostic ultrasound, 2nd ed. Philadelphia: Saunders. 2002; 2: 354-355.
  13. Kienle RD, Thomas WP. Echocardiography. In Small animal diagnostic ultrasound, 2nd ed. Philadelphia: Saunders. 2002; 2:
  14. Lewis JF, Kuo LC, Nelson JG, Limacher MC, Quinones MA. Pulsed Doppler echocardiographic determination of stroke volume and cardiac output: clinical validation of two new methods using the apical window. Circulation 1984; 70: 425-431. https://doi.org/10.1161/01.CIR.70.3.425
  15. Nishikawa T, Dohi S. Errors in the measurement of cardiac output by thermodilution. Can J Anaesth 1993; 40: 142-153. https://doi.org/10.1007/BF03011312
  16. Otterstad JE, Froeland G, St John Sutton M, Holme I. Accuracy and reproducibility of biplane two-dimensional echocardiographic measurements of left ventricular dimensions and function. Eur Heart J 1997; 18: 507-513. https://doi.org/10.1093/oxfordjournals.eurheartj.a015273
  17. Otterstad JE, St John Sutton M, Froland G, Skjaerpe T, Graving B, Holmes I. Are changes in left ventricular volume as measured with the biplane Simpson's method predominantly related to changes in its area or long axis in the prognostic evaluation of remodelling following a myocardial infarction. Eur J Echocardiogr 2001; 2: 118-125. https://doi.org/10.1053/euje.2001.0084
  18. Park K, Yeon S, Lee H. Comparative evaluation of cardiac output using echocardiography in beagle dogs. J Vet Clin 2012; 29: 384-390.
  19. Rezende ML, Pypendop BH, Ilkiw JE. Evaluation of transesophageal echo-Doppler ultrasonography for the measurement of aortic blood flow in anesthetized cats. Am J Vet Res 2008; 69: 1135-1140. https://doi.org/10.2460/ajvr.69.9.1135
  20. Schober KE, Fuentes VL, Bonagura JD. Comparison between invasive hemodynamic measurements and noninvasive assessment of left ventricular diastolic function by use of Doppler echocardiography in healthy anesthetized cats. Am J Vet Res 2003; 64: 93-103. https://doi.org/10.2460/ajvr.2003.64.93
  21. Slama M, Susic D, Varagic J, Ahn J, Frohlich ED. Echocardiographic measurement of cardiac output in rats. Am J Physiol Heart Circ Physiol 2003; 284: 691-697.
  22. Smartt S. The pulmonary artery catheter: gold standard or redundant relic. J Perianesth Nurs 2005; 20: 373-379. https://doi.org/10.1016/j.jopan.2005.09.006
  23. Sugioka K, Hozumi T, Yagi T, Yamamuro A, Akasaka T, Takeuchi K, Homma S, Yishida K, Yoshikawa J. Automated quantification of left ventricular function by the automated contour tracking method. Echocardiography 2003; 20: 313-318. https://doi.org/10.1046/j.1540-8175.2003.03036.x
  24. Yamashita K, Ueyama Y, Miyoshi K, Igarashi R, Kushiro T, Umar MA, Muir WW. Minimally invasive determination of cardiac output by transthoracic bioimpedance, partial carbon dioxide rebreathing, and transesophageal Doppler echocardiography in beagle dogs. J Vet Med Sci 2007; 9: 43-47.