DOI QR코드

DOI QR Code

LDL Cholesterol Testing Device using Serial Reflected Face-to-Face Mirror System

  • Choi, Min-Seong (School of Information and Communication Engineering, Sungkyunkwan University) ;
  • Yoo, Jae-Chern (School of Information and Communication Engineering, Sungkyunkwan University)
  • 투고 : 2013.05.15
  • 심사 : 2013.07.29
  • 발행 : 2013.08.25

초록

A low density lipoprotein (LDL) cholesterol testing device, structured with serial reflected face-to-face mirror (SRM) allowing spectrophotometry measurements, is presented. The spectrophotometry has been employed to measure the amount of light that a sample absorbs, but it generally should have had path length longer than 10 mm to secure enough sensitivity. Such requirement of path length has often been problematic in implementing a thin type of lab on a disc (LOD). We developed the SRM system which was implemented in a detection chamber with 1.4mm thickness, providing path length longer than 10mm, and thus straightforwardly being applicable to LOD as thin as a compact disc. The experimental results show that the SRM system gives not only a much thinner design compared to the conventional spectrophotometry-based LOD but also a comparable performance to already commercialized spectrometers.

키워드

참고문헌

  1. J. R. Crouse, J. S. Parks, H. M. Schey, and F. R. Kahl, "Studies of low density lipoprotein molecular weight in human beings with coronary artery disease," Journal of Lipid Research 26, 566-574 (1985).
  2. Z. Matharu, G. Sumana, M. K. Pandey, V. Gupta, and B. D. Malhotra, "Low density lipoprotein sensor based on surface plasmon resonance," Thin Solid Films 518, 719-723 (2009). https://doi.org/10.1016/j.tsf.2009.07.077
  3. Z. Matharu, A. J. Bandodkar, G. Sumana, P. R. Solanki, E. M. I. M. Ekanayake, K. Kaneto, V. Gupta, and B. D. Malhotra, "Low density lipoprotein detection based on antibody immobilized self-assembled monolayer: Investigations of kinetic and thermodynamic properties," J. Phys. Chem. B 113, 14405-14412 (2009). https://doi.org/10.1021/jp903661r
  4. L. Charpentier and N. E. Murr, "Amperometric determination of cholesterol in serum with use of a renewable surface peroxidase electrode," Analytica Chimica Acta 318, 89-93 (1995). https://doi.org/10.1016/0003-2670(95)00311-8
  5. T. Nakaminami, S. Ito, S. Kuwabata, and H. Yoneyama, "Amperometric determination of total cholesterol at gold electrodes covalently modified with cholesterol oxidase and cholesterol esterase with use of thionin as an electron mediator," Anal. Chem. 71, 1068-1076 (1999). https://doi.org/10.1021/ac9805450
  6. T. Nakaminami, S. Kuwabata, and H. Yoneyama, "Electrochemical oxidation of cholesterol catalyzed by cholesterol oxidase with use of an artificial electron mediator," Anal. Chem. 69, 2367-2372 (1997). https://doi.org/10.1021/ac960996p
  7. M. A. T. Gilmartin and J. P. Hart, "Fabrication and characterization of a screen-printed, disposable, amperometric cholesterol biosensor," Analyst 119, 2331-2336 (1994). https://doi.org/10.1039/an9941902331
  8. M. Situmorang, P. W. Alexander, and D. B. Hibbert, "Flow injection potentiometry for enzymatic assay of cholesterol woth a tungsten electrode sensor," Talanta 49, 639-679 (1999). https://doi.org/10.1016/S0039-9140(99)00057-0
  9. E. Koller, O. Quehenberger, G. Jurgens, O. S. Wolfbeis, and H. Esterbauser, "Investigation of human plasma low density lipoprotein by three-dimensional fluorescence spectroscopy," FEBS letters 198, 229-234 (1986). https://doi.org/10.1016/0014-5793(86)80411-2
  10. K. Z. Liu, R. A. Shaw, A. Man, T. C. Dembinski, and H. H. Hantsch, "Reagent-free, simultaneous determination of serum cholesterol in HDL and LDL by infrared spectroscopy," Clinical Chemistry 48, 499-506 (2002).
  11. B. S. Lee, Y. U. Lee, H. S. Kim, T. H. Kim, J. Park, J. G. Lee, J. T. Kim, H. S. Kim, W. G. Lee, and Y. K. Cho, "Fully integrated lab-on-a-disc for simultaneous analysis of biochemistry and immunoassay from whole blood," Lab Chip 11, 70-78 (2011). https://doi.org/10.1039/c0lc00205d
  12. D. C. Duffy, H. L. Gillis, J. Lin, N. F. Sheppard, Jr., and G. J. Kellogg, "Microfabricated centrifugal microfluidic systems: characterization and multiple enzymatic assays," Anal. Chem. 71, 4669-4678 (1999). https://doi.org/10.1021/ac990682c
  13. D. D. Nolte, "Invited review article: review of centrifugal microfluidic and bio-optical disks," Review of Scientific Instruments 80, 101101 (2009). https://doi.org/10.1063/1.3236681
  14. R. Corkin, M. Czugala, C. Rovira-Borras, J. Ducree, D. Diamond, and F. B. Lopez, "A wireless paired emitter detector diode device as an optical sensor for lab-on-a-disc applications," in Proc. Transducers'11 (Beijing, China, June 2011), pp. 2526-2529.
  15. T. O. Tiffany, C. A. Burtls, J. C. Mailen, and L. H. Thacker, "Dynamic multicuvette fluorometer-spectrophotometer based on the GeMSAEC face analyzer principle," Anal. Chem. 45, 1716-1723 (1973). https://doi.org/10.1021/ac60331a023
  16. J. Steigert, M. Grumann, T. Brenner, L. Riegger, J. Harter, R. Zengerle, and J. Ducree, "Fully integrated whole blood testing by real-time absorption measurement on a centrifugal platform," Lab chip 6, 1040-1044 (2006). https://doi.org/10.1039/b607051p
  17. M. Grumann, I. Moser, J. steigert, L. Riegger, A. Geipel, C. Kohn, G. Urban, R. Zengele, and J. ducree, "Optical beam guidance in monolithic polymer chips for miniaturized colorimetric assays," in Proc. Micro Electro Mechanical Systems, MEMS 2005 (Miami, FL, USA, 2005), pp. 108-111.

피인용 문헌

  1. Directional Radiation of Surface Plasmon Polaritons at Visible Wavelengths through a Nanohole Dimer Optical Antenna Milled in a Gold Film vol.18, pp.6, 2014, https://doi.org/10.3807/JOSK.2014.18.6.799