두 종류의 다른 작동유체가 ORC 시스템의 성능에 미치는 영향

Performance Analysis of an ORC System for Two Different Working Fluids

  • 장홍순 (한국산업기술대학교 에너지전기과) ;
  • 송영길 ((주)거나백) ;
  • 한영섭 (한국산업기술대학교 에너지전기과)
  • 투고 : 2013.03.27
  • 발행 : 2013.07.10

초록

The organic Rankine Cycle (ORC) uses a kind of refrigerant as a working fluid that evaporates at relatively low temperature, as the Rankine Cycle uses superheated steam as the working fluid. A small scale ORC test bench was installed, and two different working fluids (R245fa and R134a) were injected into the test bench. The test bench was in operation with the two different working fluids under the same conditions. The effects against the system performance from the different working fluids were analysed, and root causes were identified. Other factors reflecting the power generation efficiency were also found. A conclusion was drawn, that R245fa makes the system perform better, than R134a.

키워드

참고문헌

  1. Chang, H. S., Song, Y. K., and Han, Y. S., 2012, Interim Report on Development of Efficiency Assessment Technology for Secondary Power Generation Systems, KPU, pp. 7-23.
  2. Buijtenen, J. V., 2011, Design, Developen and Operation of the Tri-O-Gen ORC Power Unit, Tri-O-Gen, Sep. 2011.
  3. Park, H. S., Cho, H. C., and Lee, Y. K., 2001, Development of 1MW ORganic Rankine Cycle System, Energy Engg. J(2001), Vol. 10, No. 4, pp. 318-326.
  4. Korea Institute of Energy Research, 1991, For the utilization of waste heat recovery Organic Rankine Cycle Development and Application Research(iii), Korea Institute of Energy Research.
  5. Vankeirsblick, I., Vanslambrouck, B., Gusev, S., and De Paepe, M., 2011, Organic Rankine Cycle as Efficient Alternative to Steam Cycle for Small Scale Power Generation, HEFAT2011, July 2011.