전부도재관용 지르코니아의 표면처리에 따른 표면특성 및 계면특성 관찰

Interface and Surface Properties by Surface Treatment of Zirconia for All Ceramic Crown

  • 김치영 (부산가톨릭대학교 보건과학대학 치기공학과) ;
  • 정인성 (부산가톨릭대학교 보건과학대학 치기공학과) ;
  • 최성민 (부산가톨릭대학교 보건과학대학 치기공학과)
  • 투고 : 2013.04.25
  • 심사 : 2013.06.25
  • 발행 : 2013.07.01

초록

Purpose: This study was to observe the surface and interfacial characteristic of Zirconia by surface treatment. And it was observed the roughness and contact angle according to processing, and the interfacial properties by surface treatment on zirconia. Methods: The oxide formation and ion diffusion between core and veneer ceramic were determined by the X-ray Dot Mapping of EPMA(Electron probe micro analyzer). The roughness was measured by 3D Digital microscope and the contact angle according to processing of zirconia was observed using distilled water on the surface. Results: The surface roughness of the specimens Z04, Z12, Z15 was measured $0.67({\pm}0.03){\mu}m$, $0.50({\pm}0.12){\mu}m$, $0.35({\pm}0.09){\mu}m$, respectively. As results of contact angle test, Z04, Z12, Z15 of specimen group without binder treatment was measured $46.79({\pm}3.17)^{\circ}$, $57.47({\pm}4.83)^{\circ}$, $56.19({\pm}2.66)^{\circ}$, respectively. but, L04, L12, L15 of specimen group without binder treatment was measured $63.84({\pm}2.20)^{\circ}$, $66.08({\pm}0.16)^{\circ}$, $65.10({\pm}1.01)^{\circ}$, respectively. Average contact angle of L15 was measured $65.10({\pm}1.01)^{\circ}$. In X-ray Dot Mapping results, thickness of binder including Al element was measured that each of L04, L12, L15 were $20{\mu}m$, $15{\mu}m$, $10{\mu}m$. Conclusion: The more rough surface increases the wettability, but the sintered exclusive binder decreases the wettability.

키워드

참고문헌

  1. Aboushelib MN, Kler M, Feilzer AJ. Effect of veneering method on the fracture and bond strength of bilayered zirconia restoration. Int J Prosthodont, 21, 237-240, 2008.
  2. Blatz MB. Long Term Clinical Success of All Ceramic Posterior Restorations, Quintessence Int, 33(6), 415-426, 2002.
  3. Cho SH. On the shear bond strengths of zirconia according to the various types of surface treatment and cement. Department of prosthodontic, college of dentistry, Dankook University, 2006.
  4. Dong JK, Luthy H, Wohlwend A, Scharer P. Heat-pressed ceramics; Technology and strength. Int J Prosthodont, 5, 9-16, 1992.
  5. Friedlander LD, Munoz CA, Goodacre CJ. The Effect of Tooth Preparation Design on the Breaking Strength Dicor Crowns. Part I, Int J Prosthodont, 3, 159-168, 1990.
  6. Kem M, Fechtig T, Strub J. Influence of Water Storage and Thermal Cycling on the Fracture Strength of All-Ceramic, Resin-Bonded Fixed Partial Dentures, J Prosthet Dent, 71, 251-256, 1994. https://doi.org/10.1016/0022-3913(94)90463-4
  7. Kim DY, Lee YS, Park WH. Comparative Study of Fracture Strength Depending on the Thickness of some All Ceramic Cores, J Kor Acad Prosthodont, 42, 49-56, 2004.
  8. McCormick JT, Rowland W, Shilingburg Jr HT, Duncanson Jr MG. Effect of Luting Media on the Compressive Strengths of Two Types of All-Ceramic Crown, Quintessence Int, 24, 405-408, 1993.
  9. Olsson KG, Furst B, Anderson B, Carlsson GE. A long term retrospective and clinical follow-up study of In-ceram Alumina FPDs. Int J Prosthodont. 16, 150-156, 2003.
  10. Potiket N, Chiche G, Finger IM. In Vitro Fracture Strength of Teeth Restored with Different All-Ceramic Crown Systems, J Prosthet Dent, 92, 491-495, 2004. https://doi.org/10.1016/j.prosdent.2004.09.001
  11. Probster L, Diehl J. Slip casting alumina ceramics for crown and bridge restorations. Quintessence Int, 23, 1-31, 1992.
  12. Scherrer SS, Rijk WG. The Fracture Resistance of All-Ceramic Crowns on Supporting Structures with Different Elastic Moduli, Int J Prosthodont, 6, 462-467, 1993.
  13. Strub JR, Beschnidt SM. Fracture strength of 5 different all-ceramic crown systems. Int J Prosthodont 11, 602-609, 1998.

피인용 문헌

  1. 치과용 지르코니아 표면처리방법에 따른 지르코니아와 전장용 도재의 결합강도 관찰 vol.41, pp.4, 2013, https://doi.org/10.14347/kadt.2019.41.4.279