Abstract

In this study, three different types of experimental models of BIPV curtain wall units with GIGS modules were built, and their thermal and electrical performances were analyzed. The experimental results showed that the temperature of the rear side of the GIGS module with the application of an insulation in the curtain wall spandrels was higher than a GIGS module standalone by $22^{\circ}C$, which results in a reduction in the power generation of the former by 8 %. On the other hand, when ventilation was applied to the model to improve the power generation performance, the module temperature was observed to be $142^{\circ}C$ lower compared to the enclosed type, and the power generation performance improved by 5 %. It confirmed that the temperature increase in the rear side of the GIGS module with insulation layer reduced the electrical performance of the module. Based on this, it is claimed that providing sufficient ventilation at the GIGS applied spandrels contribute to improve the power generation of the GIGS module.

Keywords

References

  1. Wiedeman. S, Beck. M. E, Butcher. R, Repins. I, Gomez. N, Joshi. B, Wendt. R. G and Britt. J. S, CIGS Module Development on Flexible Substrates, Twenty-Ninth IEEE PVSC, 2002, pp. 575-578.
  2. Malmstrom. J, Wennerberg. J and Stolt. L, A study of the influence of the Ga content on the long-term stability of Cu(In, Ga)Se2 thin film solar cells, Thin Solid Films, 2003, pp. 436-442.
  3. Beck. M. E, Wiedeman. S, Huntington. R, Van Alsburg. J, Kanto. E, Butcher. R and Britt. J. S, Advancements in Flexible CIGS Module Manufacturing, Thirty-First IEEE PVSC, 2004, pp. 211-214.
  4. Yoon. J. H, Oh. M. H, Kang. G. H and Lee. J. B, Annual Base Performance Evaluation on Cell Temperature and Power Generation of c-Si Transparent Spandrel BIPV Module depending on the Backside Insulation Level, Journal of the Korean Solar Energy Society, Vol. 32, No. 4, 2012, pp. 24-34. https://doi.org/10.7836/kses.2012.32.4.024
  5. Yoon. J. H, Kim, D, S, Oh. M. H, and Lee. J. B, Temperature and Power Generation Characteristics of c-SiG/G Spandrel Window depending on Opening Ratio of PV Module, Journal of the Korean Solar Energy Society, Vol. 32, No. 4, 2012, pp. 51-58. https://doi.org/10.7836/kses.2012.32.4.051
  6. Lee, D, H, Son, W, D, Choi, H, S and Choi, Y, S, A Study on the Change of Surface Temperature of Back Panel by Variation of the Air -Space Distances on the Inside of Curtain Wall, J. Korean Society of Industrial Application, Vol. 14, No. 3, 2011, pp. 87-93.
  7. Lim, J, W, Oh, M, S and Kim, H, S, The development of envelop using BIPV-Focused on the unification possibility to the Curtain Wall, Architectural Institute of Korea, Vol. 20, No. 2, 2004, pp. 169-176.
  8. Solar & Energy, Technology Trend and Market Prospect of BIPV, Solar & Energy , 2011.
  9. Q.SMART U F L110 manual, Sophisticated design for a broad range of applications, Q-Cell