A Case Demonstrating a Percutaneous Closure Using the Amplatzer Duct Occluder for Paravalvular Leakage after Tricuspid Valve Replacement

  • Heo, Young Hee (Department of Pediatrics, School of Medicine, Kyung Hee University) ;
  • Kim, Soo-Jin (Division of Pediatric Cardiology, Department of Pediatrics, Konkuk University School of Medicine) ;
  • Lee, Sang Yun (Department of Pediatrics, Sejong General Hospital) ;
  • Baek, Jae Suk (Department of Pediatrics, Sejong General Hospital)
  • Published : 2013.04.30

Abstract

There has been a dramatic increase in the number and type of procedures performed in the field of cardiac intervention in the past decade. Percutaneous intervention is becoming an increasingly recognized modality for the management of prosthetic paravalvular leakages (PVLs) in severely symptomatic non-surgical candidates. Herein, we report our experience of percutaneous closure using the Amplatzer duct occluder for a PVL in a patient who underwent tricuspid valve replacement.

Keywords

References

  1. King TD, Thompson SL, Steiner C, Mills NL. Secundum atrial septal defect. Nonoperative closure during cardiac catheterization. JAMA 1976;235:2506-9. https://doi.org/10.1001/jama.1976.03260490024013
  2. Rashkind WJ, Mullins CE, Hellenbrand WE, Tait MA. Nonsurgical closure of patent ductus arteriosus: clinical application of the Rashkind PDA Occluder System. Circulation 1987;75:583-92. https://doi.org/10.1161/01.CIR.75.3.583
  3. Piechaud JF. Percutaneous closure of mitral paravalvular leak. J Interv Cardiol 2003;16:153-5. https://doi.org/10.1046/j.1540-8183.2003.08028.x
  4. Moscucci M, Deeb GM, Bach D, Eagle KA, Williams DM. Coil embolization of a periprosthetic mitral valve leak associated with severe hemolytic anemia. Circulation 2001;104:E85-6. https://doi.org/10.1161/hc4101.096829
  5. Hein R, Wunderlich N, Robertson G, Wilson N, Sievert H. Catheter closure of paravalvular leak. EuroIntervention 2006;2:318-25.
  6. Orszulak TA, Schaff HV, Danielson GK, Pluth JR, Puga FJ, Piehler JM. Results of reoperation for periprosthetic leakage. Ann Thorac Surg 1983;35:584-9. https://doi.org/10.1016/S0003-4975(10)61067-3
  7. Davila-Roman VG, Waggoner AD, Kennard ED, et al. Prevalence and severity of paravalvular regurgitation in the Artificial Valve Endocarditis Reduction Trial (AVERT) echocardiography study. J Am Coll Cardiol 2004;44:1467-72. https://doi.org/10.1016/j.jacc.2003.12.060
  8. Sorajja P, Cabalka AK, Hagler DJ, et al. Successful percutaneous repair of perivalvular prosthetic regurgitation. Catheter Cardiovasc Interv 2007;70:815-23. https://doi.org/10.1002/ccd.21270
  9. Rallidis LS, Moyssakis IE, Ikonomidis I, Nihoyannopoulos P. Natural history of early aortic paraprosthetic regurgitation: a five-year follow-up. Am Heart J 1999;138(2 Pt 1):351-7. https://doi.org/10.1016/S0002-8703(99)70124-9
  10. Dhasmana JP, Blackstone EH, Kirklin JW, Kouchoukos NT. Factors associated with periprosthetic leakage following primary mitral valve replacement: with special consideration of the suture technique. Ann Thorac Surg 1983;35:170-8. https://doi.org/10.1016/S0003-4975(10)61456-7
  11. Bhindi R, Bull S, Schrale RG, Wilson N, Ormerod OJ. Surgery Insight: percutaneous treatment of prosthetic paravalvular leaks. Nat Clin Pract Cardiovasc Med 2008;5:140-7. https://doi.org/10.1038/ncpcardio1112
  12. Lasorda DM, Mohsin JC. Percutaneous closure of perivalvular mitral regurgitation with an Amplatzer occluder device in a patient with both prosthetic mitral and aortic valves. J Interv Cardiol 2008;21:190-5. https://doi.org/10.1111/j.1540-8183.2007.00343.x
  13. Echevarria JR, Bernal JM, Rabasa JM, Morales D, Revilla Y, Revuelta JM. Reoperation for bioprosthetic valve dysfunction. A decade of clinical experience. Eur J Cardiothorac Surg 1991;5:523-6; discussion 527. https://doi.org/10.1016/1010-7940(91)90105-S
  14. Hourihan M, Perry SB, Mandell VS, et al. Transcatheter umbrella closure of valvular and paravalvular leaks. J Am Coll Cardiol 1992;20:1371-7. https://doi.org/10.1016/0735-1097(92)90250-Q
  15. Pate GE, Thompson CR, Munt BI, Webb JG. Techniques for percutaneous closure of prosthetic paravalvular leaks. Catheter Cardiovasc Interv 2006;67:158-66. https://doi.org/10.1002/ccd.20560
  16. Kort HW, Sharkey AM, Balzer DT. Novel use of the Amplatzer duct occluder to close perivalvar leak involving a prosthetic mitral valve. Catheter Cardiovasc Interv 2004;61:548-51. https://doi.org/10.1002/ccd.10785
  17. Fanning JP, Cox SV, Scalia GM. Percutaneous closure of an aortic prosthetic paravalvar leak: an Australian first. Heart Lung Circ 2012;21:174-7. https://doi.org/10.1016/j.hlc.2011.09.008