DOI QR코드

DOI QR Code

Experimental Evaluation for Ultimate Flexural Behaviors of PSC beams with A Corroded Tendon

PS강연선이 부식된 PSC보의 극한휨거동 평가실험

  • Youn, Seok-Goo (Department of Civil Engineering, Seoul National University of Science &Technology)
  • 윤석구 (서울과학기술대학교 건설시스템디자인공학과)
  • Received : 2012.10.12
  • Accepted : 2013.04.23
  • Published : 2013.05.30

Abstract

This paper presents experimental research work for the evaluation of ultimate flexural behaviors of prestressed concrete beams with a corroded tendon. In order to evaluate the effects of loss of prestress or loss of tendon area on the ultimate flexural strength of prestressed concrete beams, static load tests are conducted using five prestressed concrete beams. After exposing prestressing tendons in two test beams using 25mm drill bit, the exposed tendons were corroded using an accelerating corrosion equipment to simulate loss of tendon area. During the tests, steel strains, concrete strains and displacements at the center of test beams were measured, and acoustic emission measurements were conducted to detect wire fractures. Based on the test results, evaluation method for predicting flexural strength of prestressed concrete beams with corroded tendons is investigated. In addition, evaluation methods for predicting the existence of corroded tendons in post-tensioned prestressed concrete beams at service loads are discussed.

이 논문에는 PS강연선이 부식된 PSC보부재의 극한휨거동을 평가하기 위해 수행한 실험연구를 수록하였다. 프리스트레스 감소와 PS강연선의 단면적 감소가 PSC보의 휨강도에 미치는 영향을 평가하기 위해 5개의 PSC보부재를 이용하여 정적하중 재하실험을 수행하였다. 두 개의 PSC보부재는 드릴을 이용해 덕트 내부에 있는 PS강연선 표면을 노출시킨 후 부식촉진장치를 이용해 인위적으로 PS강선들을 부식시켰다. 실험부재의 파괴시까지 정적하중을 재하하면서 철근과 콘크리트의 변형률, 그리고 중앙부의 처짐량 변화를 측정하였으며 또한 음향센서를 콘크리트표면에 부착하여 부식된 PS강선의 파단을 모니터링하였다. 실험결과를 토대로 PS강선이 부식된 PSC보부재의 휨강도 평가방법을 분석하였다. 또한, 사용하중 작용시 후긴장된 PSC보부재 내부의 PS강연선의 부식 여부를 조기 예측할 수 있는 방법을 고찰하였다.

Keywords

References

  1. AASHTO (2003). Manual for condition evaluation and load and resistance factor rating (LRFR) of highway bridges, AASHTO, Washington, D.C., U.S.A.
  2. Fricker, S., and Vogel, T. (2006). "Site installation and testing of a continuous acoustic monitoring." Construction and Building Materials, 21, pp. 501-510.
  3. Halsall, A. P. Welch, W. E., and Trepanier, S. M. (1996). "Acoustic monitoring technology for post-tensioned concrete structures." Proceeding of the FIP Symposium 1996 on Post-tensioned Concrete Structures, The Concrete Society, pp. 483-491.
  4. Kim, Y. T., Youn, S. G., and Kim, E. K. (2007). "Experimental test for measuring prestress in PSC beam using flat-jack," Proceedings of the Annual Conference of Korea Concrete Institute, KCI, Vol. 19, No. 1, pp. 501-504 (in Korean).
  5. Mathy, B. Demars, P. Roisin, F., and Wouters, M. (1996). "Investigation and strengthening study of twenty damaged bridges: A Belgium Case History." Bridge Management : Inspection, Maintenance and Repair, Proceedings of the 3rd International Conference., Transportation Research Board, University of Surrey, pp. 658-666.
  6. National Standard of Canada (2000). Canadian highway bridge design code, CSA International, CAN/CSA-S6-00, Ontario, Canada.
  7. Park, S. H., Youn, S. G., and Kim, E. K. (2008). "Ultimate flexural behavior of PSC beams with corroded tendons." Proceedings of the Annual Conference of Korean Society of Civil Engineers, KSCE, pp. 2308-2311 (in Korean).
  8. The Concrete Society (1996). Durable bonded post-tensioned concrete bridges, Concrete Society Technical Report 47, TR047, England.
  9. Woodward, R. J., and Williams, F. W. (1988). "Collapse of ynys-sgwas bridge." Proceedings of the Institute of Civil Engineers, West Glamorgan, Part 1, Vol. 84, pp. 635-669. https://doi.org/10.1680/iicep.1988.179
  10. Youn, S. G. (2000). "Development of corrosion monitoring techniques for reinforcements and prestressing tendons." Proceedings of the Annual Conference of Korea Concrete Institute, KCI, Vol. 12, No. 2, pp. 1297-1302 (in Korean).
  11. Youn, S. G., Cho, S. K., and Kim, E. K. (2005). "Acoustic emission technique for detection of corrosion-induced wire fracture." Key Engineering Materials, Vols. 297-300, pp. 2040-2045. https://doi.org/10.4028/www.scientific.net/KEM.297-300.2040
  12. Youn, S. G., Kim, E. K., Choi, M., and Kim, H. (2005). "Analysis of acoustic signals of tendon fractures." Proceedings of the Annual Conference of Korea Concrete Institute, KCI, Vol. 17, No. 2, pp. 243-246 (in Korean).
  13. Youn, S. G., Lee, C., and Kim, E. K. (2006). "Estimation of velocities of acoustic signals and source locations in PSC beam by acoustic emission." Journal of the Korean Society of Civil Engineers, KSCE, Vol. 26, No. 5A, pp. 917-925 (in Korean).