Acknowledgement
Supported by : Natural Science Foundation of China
References
- Akinci, N.O. (2009), "An investigation on seismic resistance of reinforced concrete industrial chimneys", Proceedings of the 2009 Structures Congress - Don't Mess with Structural Engineers: Expanding Our Role, 964-971.
- Cao, H., Reinhorn, A.M. and Soong, T.T. (1998), "Design of an active mass damper for a tall TV tower in Nanjing, China", Eng. Struct., 20(3), 134-143. https://doi.org/10.1016/S0141-0296(97)00072-2
- Feng, M.Q., Kim, J.M. and Xue, H. (1998), "Identification of a dynamic system using ambient vibration measurements", J. Appl. Mech. Trans. ASME, 65(4), 1010-1021. https://doi.org/10.1115/1.2791895
- Feng, Maria Q. and Zhang, R. (1997), "Wind-induced vibration characteristics of Nanjing TV tower", Int. J. Nonlinear Mech., 32(4), 693-706. https://doi.org/10.1016/S0020-7462(96)00095-9
- Gould, P.L. and Huang, W. (2006), "Higher mode effects in the nonlinear static analysis of a collapsed chimney", Proceedings of the 2006 Structures Congress and Exposition, 19.
- Gould, P.L. and Huang, W. (2009), "Nonlinear analysis of a collapsed reinforced concrete chimney", Proceedings of the 2009 Structures Congress - Don't Mess with Structural Engineers: Expanding Our Role, 994-999.
- Goyal, A. and Maiti, M.K. (1997), "Inelastic seismic resistance of reinforced concrete stack-like structures", Earthq. Eng. Struct. D., 26(5), 501-513. https://doi.org/10.1002/(SICI)1096-9845(199705)26:5<501::AID-EQE665>3.0.CO;2-L
- Huang, W. and Gould, P.L. (2007), "3-D pushover analysis of a collapsed reinforced concrete chimney", Finite Elem. Anal. Des., 43(11-12), 879-887. https://doi.org/10.1016/j.finel.2007.05.005
- Huang, W., Gould, P.L., Martinez, R. and Johnson, G.S. (2004), "Non-linear analysis of a collapsed reinforced concrete chimney", Earthq. Eng. Struct. D., 33(4), 485-498. https://doi.org/10.1002/eqe.362
- Halabian, A.M., Elnaggar, M.H. and Vickery, B.J. (2002), "Nonlinear seismic response of reinforced-concrete free-standing towers with application to TV towers on flexible foundations", Struct. Des. Tall Build, 11(1), 51-72. https://doi.org/10.1002/tal.190
- Khaloo, A.R., Asadpour, N. and Horr, A.M. (2001), "Full dynamic analysis of Tehran telecommunication tower; linear and nonlinear responses", Struct. Des. Tall Spec. Build., 10(4), 263-281. https://doi.org/10.1002/tal.184
- Kolsky, H. (1953), Stress wave in solids, Oxford, Clarendon Press, 71.
- Reinhorn, A.M., Soong, T.T. and Cao, H. (1995), "Preliminary evaluation of wind induced response ofNanjing TV tower", Report of US/PRC Coordination Program, State University of New York at Buffalo,Buffalo, NY.
- Wu, J.R. and Li, Q.S. (2004), "Finite element model updating for a high-rise structure based on ambient vibration measurements", Eng. Struct., 26(7), 979-990. https://doi.org/10.1016/j.engstruct.2004.03.002
- Wu, J.C. and Yang, J.N. (2000), "LQG control of lateral-torsional motion of Nanjing TV transmission tower", Earthq. Eng. Struct. D., 29(8), 1111-1130. https://doi.org/10.1002/1096-9845(200008)29:8<1111::AID-EQE957>3.0.CO;2-R
- Wilson, J.L. (2003), "Earthquake response of tall reinforced concrete chimneys", Eng. Struct., 25(1), 11-24. https://doi.org/10.1016/S0141-0296(02)00098-6
- Yahyai, M., Rezayibana, B. and Daryan, A.S. (2009), "Nonlinear seismic response of milad tower using finite element model", Struct. Des. Tall Spec. Build., 18, 877-890. https://doi.org/10.1002/tal.468
Cited by
- Explicit fiber element and its application to piers under multipulse near-fault earthquake motion pp.15417794, 2018, https://doi.org/10.1002/tal.1547
- On the wind and earthquake response of reinforced concrete chimneys vol.12, pp.5, 2013, https://doi.org/10.12989/eas.2017.12.5.559
- Zemin-yapı etkileşiminin betonarme bacaların dinamik davranışına etkisi vol.7, pp.1, 2013, https://doi.org/10.29130/dubited.465732