References
- Benedettia, A. and Mangoni,E. (2007), "Analytical prediction of composite beams response in fire situations", J Construct Steel Res, 63(2), 221-228. https://doi.org/10.1016/j.jcsr.2006.04.013
- BS 5950 (1990), The structural use of steelwork in buildings, Part 8: Code of practice for fire-resistant design, British Standards Institution, London, U.K.
- CECS200:2006 (2006), Chinese Technical Code for Fire safety of Steel Structure in Buildings, China Planning Press, Beijing. (In Chinese)
- ENV 1994-1-2 (1994), Euro code 4: Design of composite steel and concrete structures-Part 1.2: Structural Fire Design, European Committee for Standardization, Brussels.
- Fakury, R.H., Casas, E.B.L., Jr, F.P.F. and Abreu, L.M.P. (2005), "Design of semi-continuous composite steel-concrete beams at the fire limit state", J Construct Steel Res, 61(8),1094-1107. https://doi.org/10.1016/j.jcsr.2005.02.003
- GB 50017-2003 (2003), Code for Design of Steel Structure, China Architecture and Building Press, Beijing.
- Hozjan, T., Saje, M., Srpcic, S. and Planinc, I. (2011), "Fire analysis of steel-concrete composite beams with interlayer slip", Comput. Struct., 89(1-2),189-200. https://doi.org/10.1016/j.compstruc.2010.09.004
- Kodur V.K.R., Naser, M., Pakala, P. and Varma, A. (2013), "Modeling the response of composite beam-slab assemblies exposed to fire", J Construct Steel Res, 80,163-173. https://doi.org/10.1016/j.jcsr.2012.09.005
- Lamont, S., Usmani A.S. and Drysdale, D.D.(2001), "Heat transfer analysis of the composite slab in the Cardington frame fire tests", Fire Safety J., 36(8), 815-839. https://doi.org/10.1016/S0379-7112(01)00041-8
- Lie, T. T. and Denham, E.M.A. (1993), "Factors affecting the fire resistance of circular hollow steel columns filled with bar-reinforced concrete", NRC-CNRC Internal Report, No.651.
- Lu Z.D. (1989), "Research on the fire behaviour of Steel reinforced concrete beams", Doctoral thesis, Tongji University, Shanghai, China. (In Chinese)
- Ranzi, G. and Bradford M.A. (2007a), "Composite beams with both longitudinal and transverse partial interaction subjected to elevated temperatures", Eng. Struct., 29(10), 2737-2750. https://doi.org/10.1016/j.engstruct.2007.01.022
- Ranzi G. and Bradford M.A. (2007b), "Direct stiffness analysis of a composite beam-column element with partial interaction", Compos Struct, 85(15-16), 1206-1214. https://doi.org/10.1016/j.compstruc.2006.11.031
- Wang, Y. C. (1998), "Composite Beams with Partial Fire Protection", Fire Safety J., 30(4), 315-332. https://doi.org/10.1016/S0379-7112(97)00000-3
- Wellman E.I., Varma A.H., Fike R. and Kodur V. (2011), "Experimental evaluation of thin composite floor assemblies under fire loading", ASCE J Struct Eng, 137(9), 1002-16. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000451
- Zhou H.Y. (2004), "Theoretical and Experimental Research on Fire Resistance of Steel-Concrete Composite Beams", Doctoral thesis, Tongji University, Shanghai, China. (In Chinese)
- Zhou H.Y., Li G.Q. and Wang Y.Z. (2005), "Parametric studies on fire resistance of simply supported steel-concrete beams". Steel Struct., 20(6), 92-96. (In Chinese)
Cited by
- Behavior of Steel–Concrete Partially Composite Beams Subjected to Fire—Part 2: Analytical Study vol.53, pp.3, 2017, https://doi.org/10.1007/s10694-016-0624-0
- Analysis of corrugated steel web beam bridges using spatial grid modelling vol.18, pp.4, 2015, https://doi.org/10.12989/scs.2015.18.4.853
- Space grid analysis method in modelling shear lag of cable-stayed bridge with corrugated steel webs vol.24, pp.5, 2013, https://doi.org/10.12989/scs.2017.24.5.549
- Reinforcement design of the top and bottom slabs of composite box girder with corrugated steel webs vol.33, pp.4, 2013, https://doi.org/10.12989/scs.2019.33.4.537
- Practical Design Methods for Fire Resistance of Restrained Cellular Steel Beams vol.19, pp.6, 2013, https://doi.org/10.1007/s13296-019-00248-w