References
- Arnal, J.M., Garcia-Fayos, B., Lora, J., Verdu, G. and Sancho, M. (2008), "AQUAPOT: Study of several cleaning solutions to recover permeate flow in a humanitarian drinking water treatment facility based on spiral wound UF membrane, Preliminary test (I)", Desalination, 221(1-3), 331-337. https://doi.org/10.1016/j.desal.2007.01.091
- Astudillo, C., Parra, J., Gonzalez, S. and Cancino, B. (2010), "A new parameter for membrane cleaning evaluation", Sep. Purif. Technol., 73(2), 286-293. https://doi.org/10.1016/j.seppur.2010.04.015
- Awanis Hashim, N., Liu, Y. and Li, K. (2011), "Stability of PVDF hollow fibre membranes in sodium hydroxide aqueous solution", Chem. Eng. Sci., 66(8), 1565-1575. https://doi.org/10.1016/j.ces.2010.12.019
- Bas, D., Boyaci, I.H. (2007), "Modeling and optimization I: Usability of response surface methodology", J. Food Eng., 78(3) 836-845.
- Begoin, L., Rabiller-Baudry, M., Chaufer, B., Hautbois, M.C. and Doneva, T. (2006), "Ageing of PES industrial spiral-wound membranes in acid whey ultrafiltration", Desalination, 192(1-3), 25-39. https://doi.org/10.1016/j.desal.2005.10.009
- Causserand C., Rouaix S., Lafaille, J.P. and Aimar, P. (2006), "Degradation of polysulfone membranes due to contact with bleaching solution", Desalination, 199(1-3), 70-72. https://doi.org/10.1016/j.desal.2006.03.144
- Causserand, C., Rouaix S., Lafaille J.P. and Aimar, P. (2008), "Ageing of polysulfone membranes in contact with bleach solution: Role of radical oxidation and of some dissolved metal ions", Chem. Eng. Process.: Process Intensif., 47(1), 48-56. https://doi.org/10.1016/j.cep.2007.08.013
- Chen, J.P., Kim, S.L. and Ting, Y.P. (2003), "Optimization of membrane physical and chemical cleaning by a statistically designed approach", J. Membr. Sci., 219(1-2), 27-45. https://doi.org/10.1016/S0376-7388(03)00174-1
- Delaunay, D., Rabiller-Baudry, M., Paugam L., Pihlajamaki, A. and Nystrom M. (2006), "Physico-chemical characterizations of a UF membrane used in dairy application to estimate chemical efficiency of cleaning", Desalination, 200(1-3), 189-191. https://doi.org/10.1016/j.desal.2006.03.291
- Ettori, A., Gaudichet-Maurin, E., Schrotter, J.C., Aimar, P. and Causserand, C. (2011), "Permeability and chemical analysis of aromatic polyamide based membranes exposed to sodium hypochlorite", J. Membr. Sci., 375(1-2), 220-230. https://doi.org/10.1016/j.memsci.2011.03.044
- Field, R., Hughes, D., Cui, Z. and Tirlapur, U. (2008), "Some observations on the chemical cleaning of fouled membranes", Desalination, 227(1-3), 132-138. https://doi.org/10.1016/j.desal.2007.08.004
- Gaudichet-Maurin, E. and Thominette, F. (2006), "Ageing of polysulfone ultrafiltration membranes in contact with bleach solutions", J. Membr. Sci., 282(1-2), 198-204. https://doi.org/10.1016/j.memsci.2006.05.023
- Gaudichet-Maurin, E. (2005), "Caracterisation et vieillissement d'une membrane d'ultrafiltration d'eau", Ecole Nationale Superieure des Arts et Metiers, Paris.
- Lawrence, N.D., Perera, J.M., Iyer, M., Hickey, M.W. and Stevens, G.W. (2006), "The use of streaming potential measurements to study the fouling and cleaning of ultrafiltration membranes", Sep. Purif. Tech., 48(2), 106-112. https://doi.org/10.1016/j.seppur.2005.07.009
- Leperoux, C., Rabiller-Baudry, M., Delaunay, D., Diallo, H. and Paquin, L. (2012), "On the use of microwaves to accelerate ageing of an ultrafiltration PES membranes by sodium hypochlorite to establish representative ageing of what happened at industrial scale", 11th World Filtration Congress, Graz, Austria, April.
- Li, X., Li, J., Fu, X., Wickramasinghe, R. and Chen, J. (2005), "Chemical cleaning of PS ultrafilters fouled by the fermentation broth of glutamic acid", Sep. Purif. Technol., 42(2), 181-187. https://doi.org/10.1016/j.seppur.2004.07.005
- Liikanen, R., Yli-Kuivila, J. and Laukkanen, R. (2002), "Efficiency of various chemical cleanings for nanofiltration membrane fouled by conventionally-treated surface water", J. Membr. Sci., 195(2), 265-276. https://doi.org/10.1016/S0376-7388(01)00569-5
- Lindau, J. and Jonsson, A.S. (1994), "Cleaning of ultrafiltration membranes after treatment of oily waste water", J. Membr. Sci., 87(1-2), 71-78. https://doi.org/10.1016/0376-7388(93)E0064-K
- Moulin, P., Manno, P, Rouch, J.C., Serra, C., Clifton, M.J. and Aptel, P. (1999), "Flux improvement by Dean vortices: ultrafiltration of colloidal suspensions and macromolecular solutions", J. Membr. Sci., 156(1), 109-130. https://doi.org/10.1016/S0376-7388(98)00333-0
- Munoz-Aguado, M.J, Wiley, D.E. and Fane, A.G. (1996), "Enzymatic and detergent cleaning of a polysulfone ultrafiltration membrane fouled with BSA and whey", J. Membr. Sci., 117(1-2), 175-187. https://doi.org/10.1016/0376-7388(96)00066-X
- Nystrom, M. and Zhu, H. (1997), "Characterization of cleaning results using combined flux and streaming potential methods", J. Membr. Sci., 131(1-2), 195-205. https://doi.org/10.1016/S0376-7388(97)00053-7
- Paugam, L., Delaunay, D. and Rabiller-Baudry, M. (2010), "Cleaning efficiency and impact on production fluxes of oxidizing disinfectants on a PES ultrafiltration membrane fouled with proteins", Food Bioprod. Process., 88(4), 425-429 https://doi.org/10.1016/j.fbp.2010.10.005
- Platt, S. and Nystrom, M. (2007), "Amido black staining of ultrafiltration membranes fouled with BSA", Desalination, 214(1-3), 177-192. https://doi.org/10.1016/j.desal.2006.09.027
- Porcelli, N. and Judd, S. (2010), "Chemical cleaning of potable water membranes: A review", Sep. Purif. Tech., 71(2), 137-143. https://doi.org/10.1016/j.seppur.2009.12.007
- Puspitasari, V., Granville, A., Le-Clech, P. and Chen, P. (2010), "Cleaning and ageing effect of sodium hypochlorite on polyvinylidene fluoride (PVDF) membrane", Sep. Purif. Technol., 72(8), 301-308. https://doi.org/10.1016/j.seppur.2010.03.001
- Rabiller-Baudry, M., Le Maux, M., Chaufer, B. and Begoin, L. (2002), "Characterization of cleaned and fouled membrane by ATR-FTIR and EDX analysis coupled with SEM: application to UF of skimmed milk with a PES membrane", Desalination, 146(1-3), 123-128. https://doi.org/10.1016/S0011-9164(02)00503-9
- Rabiller-Baudry, M., Delaunay, D., Paugam, L., Begoin, L. and Chaufer, B. (2006a), "Role of physicochemical and hydrodynamic aspects in cleaning of spiral PES ultrafiltration membranes of dairy industry", Desalination, 199(1-3), 390-392. https://doi.org/10.1016/j.desal.2006.03.210
- Rabiller-Baudry, B., Paugam, L., Begoin, L., Delaunay, D., Fernandez-Cruz, M., Phina-Ziebin, C., Laviades-Garcia de Guadiana, C. and Chaufer, B. (2006b), "Alkaline cleaning of PES membranes used in skimmed milk ultrafiltration: From reactor to spiral-wound module via a plate-and-frame module", Desalination, 191(1-3), 334-343. https://doi.org/10.1016/j.desal.2005.07.028
- Rabiller-Baudry, M., Begoin, L., Delaunay, D., Paugam, L. and Chaufer, B. (2008), "A dual approach of membrane cleaning based on physico-chemistry and hydrodynamics: Application to PES membrane of dairy industry", Chem. Eng. Process.: Process. Intensif., 47(3), 267-275. https://doi.org/10.1016/j.cep.2007.01.026
- Rabiller-Baudry, M., Paugam, L. and Delaunay, D. (2009), "Membrane cleaning: A key for sustainable production in dairy industry", Handbook of Membrane Research: Properties, Performance and Application, Chapter 6, 219-256.
- Regula, C., Carretier, E., Wyart, Y., Sergent, M., Gesan-Guiziou, G., Ferry, D., Vincent, A., Boudot, D. and Moulin, P. (2012), "Ageing of drinking water production membrane in contact with sodium hypochlorite or formulated detergents", Euromembrane, London, September.
- Shorrock, C.J. and Bird, M.R. (1998), "Membrane Cleaning: Chemically Enhanced Removal of Deposits Formed During Yeast Cell Harvesting", Food Bioprod. Process, 76(1), 30-38. https://doi.org/10.1205/096030898531729
- Te Poele, S. and Van der graaf, J. (2005), "Enzymatic cleaning in ultrafiltration of wastewater treatment plant effluent", Desalination, 179(1-3), 73-81. https://doi.org/10.1016/j.desal.2004.11.056
- Vaisanen, P., Bird, R.P. and Nystrom, M. (2002), "Treatment of UF Membranes with Simple and Formulated Cleaning Agents", Food Bioprod. Process., 80(2), 98-108. https://doi.org/10.1205/09603080252938735
- Wallberg, O., Jonsson, A.S. and Wickstrom, P. (2001), "Membrane cleaning-a case study in a sulphite pulp mill bleach plant", Desalination, 141(3), 259-268. https://doi.org/10.1016/S0011-9164(01)85004-9
- Wang, P., Wang, Z., Wu, Z., Zhou, Q. and Yang D. (2010), "Effect of hypochlorite cleaning on the physicochemical characteristics of polyvinylidene fluoride membranes", Chem. Eng. J., 162(3), 1050-1056. https://doi.org/10.1016/j.cej.2010.07.019
- Weis, A. and Bird, M.R. (2001), "The Influence of Multiple Fouling and Cleaning Cycles upon the Membrane Processing of Lignosulphonates", Food Bioprod. Process., 79(3), 184-187. https://doi.org/10.1205/096030801750425280
- Weis, A., Bird, M.R. and Nystrom, M. (2003), "The chemical cleaning of polymeric UF membranes fouled with spent sulphite liquor over multiple operational cycles", J. Membr. Sci., 216(1-2), 67-79. https://doi.org/10.1016/S0376-7388(03)00047-4
- Weis, A., Bird, M.R., Nystrom, M. and Wright, C. (2005), "The influence of morphology, hydrophobicity and charge upon the long-term performance of ultrafiltration membranes fouled with spent sulphite liquor", Desalination, 175(1), 73-85. https://doi.org/10.1016/j.desal.2004.09.024
- Zondervan, E., Zwijnenburg, A. and Roffel, B. (2007), "Statistical analysis of data from accelerated ageing tests of PES UF membranes", J. Membr. Sci., 300(1-2), 111-116. https://doi.org/10.1016/j.memsci.2007.05.015
- Zondervan, E. and Roffel, B. (2007), "Evaluation of different cleaning agents used for cleaning ultra filtration membranes fouled by surface water", J. Membr. Sci., 304(1-2), 40-49. https://doi.org/10.1016/j.memsci.2007.06.041
Cited by
- Impact of sodium hypochlorite cleaning on the surface properties and performance of PVDF membranes vol.428, 2018, https://doi.org/10.1016/j.apsusc.2017.09.056
- Membrane cleaning in membrane bioreactors: A review vol.468, 2014, https://doi.org/10.1016/j.memsci.2014.05.060
- Morphological analysis of flat and hollow fiber membranes by optical and microscopic methods as a function of the fouling vol.472, 2014, https://doi.org/10.1016/j.memsci.2014.08.012
- Development of a new method for measuring the abrasive potential of water: risk of membrane failure in water treatment plants pp.1996-9732, 2018, https://doi.org/10.2166/wst.2018.266