DOI QR코드

DOI QR Code

Improvement of Alignment Accuracy in Electron Tomography

  • Jou, Hyeong-Tae (Maritime Security Center, Korea Institute of Ocean Science & Technology) ;
  • Lee, Sujeong (Mineral Resources Research Division, Korea Institute of Geoscience and Mineral Resources) ;
  • Kim, Han-Joon (Maritime Security Center, Korea Institute of Ocean Science & Technology)
  • Received : 2013.01.22
  • Accepted : 2013.03.12
  • Published : 2013.03.30

Abstract

We developed an improved method for tilt series alignment with fiducial markers in electron tomography. Based on previous works regarding alignment, we adapted the Levenberg-Marquardt method to solve the nonlinear least squares problem by incorporating a new formula for the alignment model. We also suggested a new method to estimate the initial value for inversion with higher accuracy. The proposed approach was applied to geopolymers. A better alignment of the tilt series was achieved than that by IMOD S/W. The initial value estimation provided both stability and a good rate of convergence since the new method uses all marker positions, including those partly covering the tilt images.

Keywords

References

  1. De Rosier D J and Klug A (1968) Reconstruction of three dimensional structures from electron micrographs. Nature 217, 130-134. https://doi.org/10.1038/217130a0
  2. Diez D C, Seybert A, and Frangakis A S (2006) Tilt-series and electron microscope alignment for the correction of the non-perpendicularity of beam and tilt-axis. Ultramicroscopy 154, 195-205.
  3. Jing Z and Sachs F (1991) Alignment of tomographic projections using an incomplete set of fiducial markers. Ultramicroscopy 35, 37-43. https://doi.org/10.1016/0304-3991(91)90042-5
  4. Jou H T, Lee S, Kim Y J, and Suk B C (2008) Model simulation for assessment of image acquisition errors affecting electron tomography. Korean J. Microscopy 38, 51-61.
  5. Kim M J, Huh Y H, Choi K J, Jun S, Je A R, Chae H, Lee C, and Kweon H S (2012) Ultra-structural abnormalities in APP/PSEN1 transgenic mouse brain as the Alzheimer's disease model. Appl. Microsc. 42, 179-185. https://doi.org/10.9729/AM.2012.42.4.179
  6. Kremer J R, Mastronarde D N, and McIntosh J R (1996) Computer visualization of three-dimensional image data using IMOD. J. Struct. Biology 116, 71-76. https://doi.org/10.1006/jsbi.1996.0013
  7. Lee K J, Kweon H S, Kang J S, and Rhyu I J (2005) 3-dimensional reconstruction of parallel fiber-Purkinje cell synapses using highvoltage electron microscopy. Korean J. Microscopy 35, 31-39.
  8. Levenberg K (1944) A method for the solution of certain problems in least squares. Quart. Appl. Math. 2, 164-168.
  9. Luther P K, Lawrence M C, and Crowther R A (1988) A method for monitoring the collapse of plastic sections as a function of electron dose. Ultramicroscopy 24, 7-18. https://doi.org/10.1016/0304-3991(88)90322-1
  10. Marquardt D (1963) An algorithm for least-squares estimation of nonlinear parameters. SIAM J. Appl. Math. 11, 431-441. https://doi.org/10.1137/0111030
  11. Midgley P A and Dunin-Borkowski R E (2009) Electron tomography and holography in materials science. Nature Mater. 8, 271-280. https://doi.org/10.1038/nmat2406
  12. Penczek P, Marko M, Buttle K, and Frank J (1995) Double-tilt electron tomography. Ultramicroscopy 60, 393-410. https://doi.org/10.1016/0304-3991(95)00078-X
  13. Scott M C, Chen C-C, Mecklenburg M, Zhu C, Xu R, Ercius P, Dahmen U, Regan B C, and Miao J (2012) Electron tomography at 2.4-angstrom resolution. Nature 483, 444-447. https://doi.org/10.1038/nature10934
  14. Ziese U, Jong K P de, and Koster A J (2004) Electron tomography: a tool for 3D structural probing of heterogeneous catalysts at the nanometer scale. App. Catal. A-Gen. 260, 71-74. https://doi.org/10.1016/j.apcata.2003.10.014