Radiation Dose Reduction via Sinogram Affirmed Iterative Reconstruction and Automatic Tube Voltage Modulation (CARE kV) in Abdominal CT

  • Shin, Hyun Joo (Department of Radiology, Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine) ;
  • Chung, Yong Eun (Department of Radiology, Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine) ;
  • Lee, Young Han (Department of Radiology, Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine) ;
  • Choi, Jin-Young (Department of Radiology, Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine) ;
  • Park, Mi-Suk (Department of Radiology, Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine) ;
  • Kim, Myeong-Jin (Department of Radiology, Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine) ;
  • Kim, Ki Whang (Department of Radiology, Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine)
  • 투고 : 2012.11.29
  • 심사 : 2013.08.01
  • 발행 : 2013.11.01

초록

Objective: To evaluate the feasibility of sinogram-affirmed iterative reconstruction (SAFIRE) and automated kV modulation (CARE kV) in reducing radiation dose without increasing image noise for abdominal CT examination. Materials and Methods: This retrospective study included 77 patients who received CT imaging with an application of CARE kV with or without SAFIRE and who had comparable previous CT images obtained without CARE kV or SAFIRE, using the standard dose (i.e., reference mAs of 240) on an identical CT scanner and reconstructed with filtered back projection (FBP) within 1 year. Patients were divided into two groups: group A (33 patients, CT scanned with CARE kV); and group B (44 patients, scanned after reducing the reference mAs from 240 to 170 and applying both CARE kV and SAFIRE). CT number, image noise for four organs and radiation dose were compared among the two groups. Results: Image noise increased after CARE kV application (p < 0.001) and significantly decreased as SAFIRE strength increased (p < 0.001). Image noise with reduced-mAs scan (170 mAs) in group B became similar to that of standard-dose FBP images after applying CARE kV and SAFIRE strengths of 3 or 4 when measured in the aorta, liver or muscle (p ${\geq}$ 0.108). Effective doses decreased by 19.4% and 41.3% for groups A and B, respectively (all, p < 0.001) after application of CARE kV with or without SAFIRE. Conclusion: Combining CARE kV, reduction of mAs from 240 to 170 mAs and noise reduction by applying SAFIRE strength 3 or 4 reduced the radiation dose by 41.3% without increasing image noise compared with the standard-dose FBP images.

키워드

참고문헌

  1. Winklehner A, Goetti R, Baumueller S, Karlo C, Schmidt B, Raupach R, et al. Automated attenuation-based tube potential selection for thoracoabdominal computed tomography angiography: improved dose effectiveness. Invest Radiol 2011;46:767-773 https://doi.org/10.1097/RLI.0b013e3182266448
  2. Hart D, Wall BF. Radiation exposure of the UK population from medical and dental X-ray Examinations. NRPB-W4. Chilton: NRPB, 2002
  3. Hur S, Lee JM, Kim SJ, Park JH, Han JK, Choi BI. 80-kVp CT using Iterative Reconstruction in Image Space algorithm for the detection of hypervascular hepatocellular carcinoma: phantom and initial clinical experience. Korean J Radiol 2012;13:152-164 https://doi.org/10.3348/kjr.2012.13.2.152
  4. Kambadakone AR, Chaudhary NA, Desai GS, Nguyen DD, Kulkarni NM, Sahani DV. Low-dose MDCT and CT enterography of patients with Crohn disease: feasibility of adaptive statistical iterative reconstruction. AJR Am J Roentgenol 2011;196:W743-W752 https://doi.org/10.2214/AJR.10.5303
  5. Brenner DJ, Hall EJ. Computed tomography--an increasing source of radiation exposure. N Engl J Med 2007;357:2277-2284 https://doi.org/10.1056/NEJMra072149
  6. Qi W, Li J, Du X. Method for automatic tube current selection for obtaining a consistent image quality and dose optimization in a cardiac multidetector CT. Korean J Radiol 2009;10:568-574 https://doi.org/10.3348/kjr.2009.10.6.568
  7. Hwang HJ, Seo JB, Lee JS, Song JW, Kim SS, Lee HJ, et al. Radiation dose reduction of chest CT with iterative reconstruction in image space - Part II: assessment of radiologists' preferences using dual source CT. Korean J Radiol 2012;13:720-727 https://doi.org/10.3348/kjr.2012.13.6.720
  8. Hwang HJ, Seo JB, Lee JS, Song JW, Kim SS, Lee HJ, et al. Radiation dose reduction of chest CT with iterative reconstruction in image space - Part I: studies on image quality using dual source CT. Korean J Radiol 2012;13:711-719 https://doi.org/10.3348/kjr.2012.13.6.711
  9. Goo HW. CT radiation dose optimization and estimation: an update for radiologists. Korean J Radiol 2012;13:1-11 https://doi.org/10.3348/kjr.2012.13.1.1
  10. Moritz JD, Hoffmann B, Sehr D, Keil K, Eggerking J, Groth G, et al. Evaluation of ultra-low dose CT in the diagnosis of pediatric-like fractures using an experimental animal study. Korean J Radiol 2012;13:165-173 https://doi.org/10.3348/kjr.2012.13.2.165
  11. McCollough CH, Primak AN, Braun N, Kofler J, Yu L, Christner J. Strategies for reducing radiation dose in CT. Radiol Clin North Am 2009;47:27-40 https://doi.org/10.1016/j.rcl.2008.10.006
  12. Winklehner A, Karlo C, Puippe G, Schmidt B, Flohr T, Goetti R, et al. Raw data-based iterative reconstruction in body CTA: evaluation of radiation dose saving potential. Eur Radiol 2011;21:2521-2526 https://doi.org/10.1007/s00330-011-2227-y
  13. Halliburton SS. Recent technologic advances in multi-detector row cardiac CT. Cardiol Clin 2009;27:655-664 https://doi.org/10.1016/j.ccl.2009.06.007
  14. Ghetti C, Ortenzia O, Serreli G. CT iterative reconstruction in image space: a phantom study. Phys Med 2012;28:161-165 https://doi.org/10.1016/j.ejmp.2011.03.003
  15. Schindera ST, Diedrichsen L, Muller HC, Rusch O, Marin D, Schmidt B, et al. Iterative reconstruction algorithm for abdominal multidetector CT at different tube voltages: assessment of diagnostic accuracy, image quality, and radiation dose in a phantom study. Radiology 2011;260:454-462 https://doi.org/10.1148/radiol.11102217
  16. Barrett HH, Swindell W. Radiological imaging: the theory of image formation, detection, and processing. New York: Academic Press, 1981
  17. The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103. Ann ICRP 2007;37:1-332
  18. Office for Official Publications of the European Communities. European guidelines on quality criteria for computed tomography. Luxembourg: Office for Official Publications of the European Communities, 1999
  19. Yu L, Bruesewitz MR, Thomas KB, Fletcher JG, Kofler JM, McCollough CH. Optimal tube potential for radiation dose reduction in pediatric CT: principles, clinical implementations, and pitfalls. Radiographics 2011;31:835-848 https://doi.org/10.1148/rg.313105079
  20. Leipsic J, LaBounty TM, Mancini GB, Heilbron B, Taylor C, Johnson MA, et al. A prospective randomized controlled trial to assess the diagnostic performance of reduced tube voltage for coronary CT angiography. AJR Am J Roentgenol 2011;196:801-806 https://doi.org/10.2214/AJR.10.5786
  21. Schindera ST, Nelson RC, Mukundan S Jr, Paulson EK, Jaffe TA, Miller CM, et al. Hypervascular liver tumors: low tube voltage, high tube current multi-detector row CT for enhanced detection--phantom study. Radiology 2008;246:125-132 https://doi.org/10.1148/radiol.2461070307
  22. Fleischmann D, Boas FE. Computed tomography--old ideas and new technology. Eur Radiol 2011;21:510-517 https://doi.org/10.1007/s00330-011-2056-z
  23. Mueck FG, Korner M, Scherr MK, Geyer LL, Deak Z, Linsenmaier U, et al. Upgrade to iterative image reconstruction (IR) in abdominal MDCT imaging: a clinical study for detailed parameter optimization beyond vendor recommendations using the adaptive statistical iterative reconstruction environment (ASIR). Rofo 2012;184:229-238 https://doi.org/10.1055/s-0031-1282032
  24. Moscariello A, Takx RA, Schoepf UJ, Renker M, Zwerner PL, O'Brien TX, et al. Coronary CT angiography: image quality, diagnostic accuracy, and potential for radiation dose reduction using a novel iterative image reconstruction techniquecomparison with traditional filtered back projection. Eur Radiol 2011;21:2130-2138 https://doi.org/10.1007/s00330-011-2164-9

피인용 문헌

  1. Can Sinogram-Affirmed Iterative Reconstruction Improve the Detection of Small Hypervascular Liver Nodules With Dual-Energy CT? vol.38, pp.5, 2014, https://doi.org/10.1097/rct.0000000000000105
  2. Non-enhanced Low-tube-voltage High-pitch Dual-source Computed Tomography with Sinogram Affirmed Iterative Reconstruction Algorithm of the Abdomen and Pelvis vol.29, pp.4, 2013, https://doi.org/10.1016/s1001-9294(14)60073-0
  3. Radiation Dose and Imaging Quality of Abdominal Computed Tomography before and after Scan Protocol Adjustment: Single-Institution Experience in Three Years vol.71, pp.6, 2014, https://doi.org/10.3348/jksr.2014.71.6.278
  4. Attenuation-Based Automatic Kilovoltage Selection and Sinogram-Affirmed Iterative Reconstruction: Effects on Radiation Exposure and Image Quality of Portal-Phase Liver CT vol.16, pp.1, 2015, https://doi.org/10.3348/kjr.2015.16.1.69
  5. Feasibility Study of Radiation Dose Reduction in Adult Female Pelvic CT Scan with Low Tube-Voltage and Adaptive Statistical Iterative Reconstruction vol.16, pp.5, 2013, https://doi.org/10.3348/kjr.2015.16.5.1047
  6. Determining and Managing Fetal Radiation Dose from Diagnostic Radiology Procedures in Turkey vol.16, pp.6, 2015, https://doi.org/10.3348/kjr.2015.16.6.1276
  7. Phantom Study on Dose Reduction Using Iterative Reconstruction in Low-dose Computed Tomography for Lung Cancer Screening vol.71, pp.12, 2013, https://doi.org/10.6009/jjrt.2015_jsrt_71.12.1201
  8. Combined Use of Automatic Tube Voltage Selection and Current Modulation with Iterative Reconstruction for CT Evaluation of Small Hypervascular Hepatocellular Carcinomas: Effect on Lesion Conspicuity a vol.16, pp.3, 2013, https://doi.org/10.3348/kjr.2015.16.3.531
  9. Low Dose Computed Tomography for 3D Planning of Total Hip Arthroplasty: Evaluation of Radiation Exposure and Image Quality vol.39, pp.5, 2013, https://doi.org/10.1097/rct.0000000000000271
  10. Performances of low-dose dual-energy CT in reducing artifacts from implanted metallic orthopedic devices vol.45, pp.7, 2013, https://doi.org/10.1007/s00256-016-2377-8
  11. Three-dimensional reconstruction of coronary arteries and plaque morphology using CT angiography – comparison and registration with IVUS vol.16, pp.None, 2016, https://doi.org/10.1186/s12880-016-0111-6
  12. CT dose reduction: approaches, strategies and results from a province-wide program in Quebec vol.36, pp.2, 2013, https://doi.org/10.1088/0952-4746/36/2/346
  13. Effective dose estimation for oncological and neurological PET/CT procedures vol.7, pp.1, 2017, https://doi.org/10.1186/s13550-017-0272-5
  14. Comparison of Chest Pain Protocols for Electrocardiography-Gated Dual-Source Cardiothoracic CT in Children and Adults: The Effect of Tube Current Saturation on Radiation Dose Reduction vol.19, pp.1, 2013, https://doi.org/10.3348/kjr.2018.19.1.23
  15. Feasibility of radiation dose reduction with iterative reconstruction in abdominopelvic CT for patients with inappropriate arm positioning vol.13, pp.12, 2013, https://doi.org/10.1371/journal.pone.0209754
  16. Comparison of standard-dose and half-dose dual-source abdominopelvic CT scans for evaluation of acute abdominal pain vol.60, pp.8, 2013, https://doi.org/10.1177/0284185118809544
  17. Determination of computed tomography number of high-density materials in 12-bit, 12-bit extended and 16-bit depth for dosimetric calculation in treatment planning system vol.18, pp.3, 2013, https://doi.org/10.1017/s1460396919000013
  18. Validation of CARE kV automated tube voltage selection for PET-CT: PET quantification and CT radiation dose reduction in phantoms vol.8, pp.1, 2013, https://doi.org/10.1186/s40658-021-00373-8