A Tapered Slot Antenna with Asymmetric Corrugations for a Microwave Brain Imaging System

전자파 두뇌 영상장치용 비대칭형 Corrugated 테이퍼드 슬롯 안테나

  • Lee, Juneseok (Department of Electronics & Computer Engineering, Hanyang University) ;
  • Park, Joongki (Department of Electronics & Computer Engineering, Hanyang University) ;
  • Choi, Jaehoon (Department of Electronics & Computer Engineering, Hanyang University)
  • 이준석 (한양대학교 전자컴퓨터통신공학과) ;
  • 박중기 (한양대학교 전자컴퓨터통신공학과) ;
  • 최재훈 (한양대학교 전자컴퓨터통신공학과)
  • Received : 2013.02.08
  • Accepted : 2013.03.08
  • Published : 2013.03.31

Abstract

Recently, a brain imaging system with microwave devices has been proposed. The brain imaging system requires a small antenna which has ultra wide band(UWB) operating frequency bandwidth(0.5~2 GHz) and non-varying boresight of antenna over the frequency band. This paper proposes asymmetric corrugations on a tapered slot antenna (TSA) so that the size of the TSA is reduced by 14 % while 10 dB return loss bandwidth is satisfied over the operating frequency band from 0.5 GHz to 2 GHz. A miniaturized TSA with symmetric corrugations shows tilted boresight whilst frequency is getting lower; however, the proposed TSA with asymmetric corrugations maintains direction of boresight for different frequencies. This enhancements make an asymmetric corrugated TSA meet the requirement of the brain imaing system.

최근 전자파를 이용하여 두뇌를 영상화하는 시스템이 제안되고 있다. 이러한 시스템은 초광대역 특성(0.5~2 GHz)과 주빔의 방향이 모든 동작 주파수 대역에서 일정하게 유지되는 소형 안테나를 요구한다. 위의 요구 조건을 만족하기 위해서 본 논문에서는 비대칭형 corrugation들을 일반 TSA에 적용하여 안테나의 크기는 14 % 감소시키고, 요구되는 동작 주파수 대역인 0.5 GHz에서 2 GHz까지 반사 손실이 10 dB 이하의 값을 가지도록 설계하였다. 특히 대칭형 corrugation들을 적용한 TSA가 가지는 주빔의 방향이 주파수에 따라 변하는 점을 개선하였고, 이러한 비대칭형 corrugated TSA는 전자파를 이용한 두뇌 영상장치의 구현을 위해서 요구되는 조건을 모두 만족한다.

Keywords

References

  1. 이순용, 서원범, 권결, 최재훈, "MICS 대역과 ISM 대역에서 인체 전기적 상수를 갖는 준(準)고체형 플랫 팬텀 제작", 한국전자파학회논문지, 23(1), pp. 101-107, 2012년 1월. https://doi.org/10.5515/KJKIEES.2012.23.1.101
  2. Yifan Wang, Marek Bialkowski., "Design of twoelement probe antenna for UWB near-field imaging", Antennas and Propagation Society International Symposium(APSURSI), IEEE, pp. 1-4, 2010.
  3. B. J. Mohammed, A. M. Abbosh, D. Ireland, and M. E. Bialkowski, "Compact wideband antenna for microwave imaging of brain", Progress in Electromagnetics Research C(PIER C), vol. 27, pp. 27-39, 2012. https://doi.org/10.2528/PIERC11102708
  4. Ireland David, Marek Bialkowski, "Feasibility study on microwave stroke detection using a realistic phantom and the FDTD method", Asia-Pacific Microwave Conference Proceedings(APMC), pp. 1360-1363, 2010.
  5. Yifan Wang, Marek Bialkowski., "A size-reduced exponentially tapered slot antenna with corrugations for directivity improvement" Asia Pacific Microwave Conference(APMC), pp. 2482-2485, 2009.
  6. A. Abbosh, "Gain and bandwidth optimization of compact UWB tapered slot antennas", Microwave and Optical Technology, vol. 2, no. 3, Jul. 2007.
  7. V. Mickhnev, P. Vainikainen, "Ultra-wideband tapered- slot antenna with non-uniform resistive loading", Antenna Theory and Technique, Sevastopol, Ukraine, pp. 281-283, Sep. 2007.
  8. W. Shen, "Study on asymmetric tapered slotline antenna", Ultrawideband and Ultrashort Impulse Signals, The Third International Conference, pp. 156-158, Sep. 2006.
  9. Juneseok Lee, Soonyong Lee, Kyeol Kwon, David Ireland, and Jaehoon Choi, "Design of a compact tapered slot antenna for brain imaging system", The Bioelectromagnetics Society 34th Annual Meeting, Brisbane, Jun. 2012.