Abstract

Bending motion has been used in the surgical instruments with bending structures and tendon mechanisms. A simplified bending angle amplification ratio between the proximal and distal bending joint was derived in this article. The bending structure of disk and rib in the proximal joint was analyzed based on finite element method with an emphasis on the circumferential uniformity of bending stiffness. Regarding the distal joint, optimal design and sensitivity analysis was done with four design variables of outer and inner diameter, rib height and rib width while maximizing the deformation under the stress distribution below the yield stress. Outer diameter and rib width are most critical to maximum deformation as the outer diameter and inner diameters are so to maximum equivalent stress.

Keywords

References

  1. Kim, J. G., Cho, H. M., and Jeong, S. K., "The past and future of laparoscopic surgery in Korea," Journal of Minimally Invasive Surgery, Vol. 7, pp. 1-10, 2004.
  2. Kim, H. J., Lee, J. I., Lee, Y. S., Kang, W. K., Lee, S. K., You, Y. K., and Oh, S. T., "A Case of Single Port Laparoscopic Appendectomy and Cholecystectomy in a Fresh Cadaver: A Feasible Procedure," J. Korean Soc. Coloproctol., Vol. 25, No. 1, pp. 59-62, 2009. https://doi.org/10.3393/jksc.2009.25.1.59
  3. Lee, W. J., "Robotics and Gastrointestinal Surgery," Journal of Minimally Invasive Surgery, Vol. 8, pp. 41-46, 2005.
  4. Kim, E. K., "Laparoscopic Surgery," J. of Korean Med. Assoc., Vol. 51, No. 9, pp. 833-837, 2008. https://doi.org/10.5124/jkma.2008.51.9.833
  5. Covidien, http://www.sils.com
  6. CambridgeEndo, http://www.cambridgeendo.com
  7. Novare RealHand Animation, http://columbiasurgery. org/scarless/instrumentation.html
  8. Olympus, http://www.olympus-global.com
  9. Adair, E. L., "Steerable sheath for use with selected removable optical catheter," US Patent, No. 5325845, 1994.
  10. Jung, Y. W., Kim, S. W., and Kim, Y. T., "Recent advances of robotic surgery and single port laparoscopy in gynecologic oncology," J. of Gynecologic Oncology, Vol. 20, pp. 137-144, 2009. https://doi.org/10.3802/jgo.2009.20.3.137
  11. Instuitive Surgical, Inc., "Surgical tool having positively positionable tendon-actuated multi-disk wrist joint," US Patent, No. 7736356B2, 2004.
  12. EndoVia Medical, Inc., "Flexible instrument," International Publication, No. WO02/074178A2, 2002.
  13. Harada, K. and Tsubouchi, K., "Micro manipulators for intrauterine fetal surgery in an open MRI," IEEE International Conference on Robotics and Automation, pp. 502-507, 2005.
  14. Yamashita, H., Iimura, A., and Aoki, E., "Development of endoscopic forceps manipulator using multi-slider linkage mechanisms," Proceeding of the 1st Asian Symposium on Computer Aided Surgery - Robotic and Image Guided Surgery, 2005.
  15. Swanstrom, L. L. and Whiteford, M., "Developing essential tools to enable transgastric surgery," Surgical Endoscopy, Vol. 22, pp. 600-604, 2008. https://doi.org/10.1007/s00464-007-9632-y
  16. Peirsa, J., Clijnena, J., and Reynaerts, D., "A micro optical force sensor for force feedback during minimally invasive robotic surgery," MME'02, The 13th Micromechanics Europe Workshop, pp. 271-274, 2002.
  17. Focacci, F., Piccigallo, M., Tonet, O., Megali, G., Pietrabissa, A., and Dario, P., "Lightweight hand-held robot for laparoscopic surgery," IEEE Int. Conf. on Robotics and Automation, pp. 599-604, 2007.
  18. Immega, G., Antonelli, K., and Ko, J., "Teleoperation of the KSI Tentacle Manipulator for hot cell decontamination," IEEE Int. Conf. on Intelligent Systems for the 21st Century, Vol. 3, pp. 2133-2136, 1995.
  19. Breedveld, P. and Scheltes, J. S., "A New, Easily Miniaturized Steerable Endoscope," IEEE Engineering in Medicine and Biology Magazine, pp. 40-47, 2005.
  20. Lee, K. H. and Kang, D. H., "Structural optimization of an automotive door using the kriging interpolation method," Proceedings of the Institution of Mechanical Engineers Part D: Journal of Automobile Engineering, Vol. 221, No. 12, pp. 1525-1534, 2007. https://doi.org/10.1243/09544070JAUTO403
  21. Lee, K. K. and Han, S. H., "Development of Computational Orthogonal Array based Fatigue Life Prediction Model for Shape Optimization of Turbine Blade," Transactions of the KSME A, Vol. 34, No. 5, pp. 611-617, 2010. https://doi.org/10.3795/KSME-A.2010.34.5.611
  22. Moon, D. H., Hwang, D. Y., Choi, S. W., and Won, J. S., "3 DOF Laparoscopic Surgical Instrument Bending Coupler Optimal Design," Proc. of KSPE Autumn Conference, pp. 779-780, 2010.
  23. Tae Sung S&X Inc., "Ansys Workbench Optimization Training Manual," 2009.
  24. Morrow, H. W. and Kokernak, R. P., "Statics and Strength of Materials, 6th ed.," Prentice Hall, 2007.