DOI QR코드

DOI QR Code

Unsteady Analysis of Hydraulic Behavior Characteristics in Water Treatment System Using CFD Simulation

CFD를 이용한 정수처리 공정 내 유량변동시 수리흐름 해석에 관한 연구

  • Received : 2013.02.19
  • Accepted : 2013.04.08
  • Published : 2013.04.15

Abstract

The fluctuation of inlet flow to a water treatment plant makes a serious problem that it can change the outlet flowrate from each process abruptly. Since it takes very short time for the surface wave occurred from the fluctuation of inlet flow to reach the latter processes, it is impossible for operators to cope with that stably. In order to investigate the characteristics of hydraulic behavior for rectangular sedimentation basin in water treatment plant, CFD(Computational Fluid Dynamics) simulation were employed. From the results of both CFD simulations, it was confirmed that time taken for the follow-up processes by the fluctuation in intake well can be estimated by the propagation velocity of surface waves. Also, it takes very short time for the surface wave occurred from the fluctuation of inlet flow to reach the latter processes. In the case of inlet flowerate being increased sharply, local velocity within sedimentation basin appeared as wave pattern and increased due to convection current. Also, it could be observed that vortex made local velocity in the vicinity of bottom rise.

Keywords

References

  1. Ministry of Environment(2011),"2010 Statistics of Waterworks"
  2. Athanasia M. Goula, Margaritis Kostoglou, Thodoris D. Karapantsios, Anastasios I. Zouboulis(2008), "A CFD methodology for the design of sedimentation tanks in potable water treatment: Case study: The influence of a feed flow control baffle", Chemical Engineering Journal, Vol. 140, Issues 1-3, pp. 110-121. https://doi.org/10.1016/j.cej.2007.09.022
  3. William B. Rauen, Binliang Lin, Roger A. Falconer, Edmilson C. Teixeira(2008), "CFD and experimental model studies for water disinfection tanks with low Reynolds number flows", Chemical Engineering Journal, Vol. 137, Issues 3, pp. 550-560. https://doi.org/10.1016/j.cej.2007.05.011
  4. Afshin Pak, Toraj Mohammadi, S.M. Hosseinalipour, Vida Allahdini(2008), "CFD modeling of porous membranes", Desalination, Volume 222, Issues 1-3, pp. 482-488. https://doi.org/10.1016/j.desal.2007.01.152
  5. D.R. K aushal, T. Thinglas, Yuji Tomita, Shigeru Kuchii, Hiroshi Tsukamoto(2012), "CFD modeling for pipeline flow of fine particles at high concentration", International Journal of Multiphase Flow, Volume 43, pp. 85-100. https://doi.org/10.1016/j.ijmultiphaseflow.2012.03.005
  6. Jong-Woong Choi, Seong-Su Kim, No-Suk Park, Young-Joo Lee, Seon-Ha Chae(2012),"UV predictions for ultra violet flowing water purification of axial reactor type based on the location of the exit by CFD", Journal of Korean Society of Water and Wastewater, Vol.26, No.4, pp.521-533 https://doi.org/10.11001/jksww.2012.26.4.521
  7. No-Suk Park, Seong-Eun Lim, Seong-Su Kim, Jun-Sik Hwang, Nahm-Chung Jung(2008), "Analysis of relationship between daily inflow rate fluctuation and surface wave transfer velocity in water treatment processes", Journal of Korean Society of Water and Wastewater, Vol.22, No.2, pp.239-243