DOI QR코드

DOI QR Code

A numerical study on the feasibility evaluation of a hybrid type superconducting fault current limiter applying thyristors

  • Received : 2013.07.31
  • Accepted : 2013.12.18
  • Published : 2013.12.31

Abstract

Smart fault current controller (SFCC) proposed in our previous work consists of a power converter, a high temperature superconducting (HTS) DC reactor, thyristors, and a control unit [1]. SFCC can limit and control the current by adjusting firing angles of thyristors when a fault occurs. SFCC has complex structure because the HTS DC reactor generates the loss under AC. To use the DC reactor under AC, rectifier that consists of four thyristors is needed and it increases internal resistance of SFCC. For this reason, authors propose a hybrid type superconducting fault current limiter (SFCL). The hybrid type SFCL proposed in this paper consists of a non-inductive superconducting coil and two thyristors. To verify the feasibility of the proposed hybrid type SFCL, simulations about the interaction of the superconducting coil and thyristors are conducted when fault current flows in the superconducting coil. Authors expect that the hybrid type SFCL can control the magnitude of the fault current by adjusting the firing angles of thyristors after the superconducting coil limits the fault current at first peak.

Keywords

References

  1. M. C. Ahn, T. K. Ko, "Proof-of-concept of a Smart Fault Controller with a Superconducting coil for the Smart Grid," IEEE Trans. Appl. Supercond., vol. 21, no. 3, pp. 2201-2204, 2011. https://doi.org/10.1109/TASC.2010.2091386
  2. L. Ye, L. Lin, K. P. Juengst, "Application Studies of Superconducting Fault Current Limiters in Electric Power Systems," IEEE Trans. Appl. Supercond., vol. 12, pp. 900-903, 2002. https://doi.org/10.1109/TASC.2002.1018545
  3. J. M. Ahn, J. S. Kim, J.F. Moon, S. H. Lim, J.C. Kim, "Analysis on the Protective Coordination in Power Distribution System with Superconducting Fault Current Limiter," Trans. KIEE, vol. 57, No. 5, pp. 755-760, 2008.
  4. J. Y. Jang, W. S. Lee, J. Lee, Y. J. Hwang, H. C. Jo, M. C. Ahn, K. Hur, T. K. Ko, "Performance evaluation on Fault Current Controller System for the Applications of Smart Grid," Journal of the Institute of Applied Superconductivity and Cryogenics, vol. 14, No. 2, pp. 1-5, 2012. https://doi.org/10.9714/psac.2012.14.2.012
  5. J. A. Waynert, H. J. Boenig, C. H. Mielke, J. O. Willis, and B. L. Burley, "Restoration and testing of an HTS fault current controller," IEEE Trans. Appl. Supercond., vol. 13, pp. 1984-1987, 2007.
  6. Muhammad H. Rashid, Power electronics, Pearson Prentice Hall, Third Edition, 2005.

Cited by

  1. Operational Characteristics of a Small-Scale Novel Hybrid Resistive-Type SFCL With Controlled Power Electronics vol.25, pp.3, 2015, https://doi.org/10.1109/TASC.2015.2391118