References
- Brahme A: Optimization of stationary and moving beam radiation therapy techniques. Radiother Oncol 12(2):129-140 (1988) https://doi.org/10.1016/0167-8140(88)90167-3
- Das IJ, Cheng C, Chopra KL, et al: Intensity-modulated radiation therapy dose prescription, recording, and delivery: Patterns of variability among institutions and treatment planning systems. J Natl Cancer Inst 100(5):300-307 (2008) https://doi.org/10.1093/jnci/djn020
- Ulmer W, Pyyry J, Kaissl W: A 3D photon superposition/ convolution algorithm and its foundation on results of Monte Carlo calculations. Phys Med Biol 50(8):1767-1790 (2005) https://doi.org/10.1088/0031-9155/50/8/010
- Gifford KA, Horton JL Jr, Wareing TA, Failla G, Mourtada F: Comparison of a finite-element multigroup discrete-ordinates code with Monte Carlo for radiotherapy calculations. Phys Med Biol 51(9):2253 (2006) https://doi.org/10.1088/0031-9155/51/9/010
- Vassiliev ON, Wareing TA, McGhee J, Failla G, Salehpour MR, Mourtada F: Validation of a new grid-based Boltzmann equation solver for dose calculation in radiotherapy with photon beams. Phys Med Biol 55(3):581-598 (2010) https://doi.org/10.1088/0031-9155/55/3/002
- Ezzell GA, Galvin JM, Low D, et al: Guidance document on delivery, treatment planning, and clinical implementation of IMRT: report of the IMRT Subcommittee of the AAPM Radiation Therapy Committee. Med Phys 30(8):2089-2115 (2003) https://doi.org/10.1118/1.1591194
- Ezzell GA, Burmeister JW, Dogan N, et al: IMRT commissioning: multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119. Med Phys 36(11):5359-5373 (2009) https://doi.org/10.1118/1.3238104
- Low DA, Dempsey JF: Evaluation of the gamma dose distribution comparison method. Med Phys 30(9):2455-2464 (2003) https://doi.org/10.1118/1.1598711
- Low DA, Harms WB, Mutic S, Purdy JA: A technique for the quantitative evaluation of dose distributions. Med Phys 25(5): 656-661 (1998) https://doi.org/10.1118/1.598248
- Both S, Alecu IM, Stan AR, et al: A study to establish reasonable action limits for patient-specific quality assurance in intensity-modulated radiation therapy. J Appl Clin Med Phys 8(2):1-8 (2007)
- Kim JI, Chung JB, Park YK, et al: A multi-institutional study for tolerance and action levels of IMRT dose quality assurance measurements in Korea. J Appl Clin Med Phys 14(2): 3964 (2013)
- Yan G, Fox C, Liu C, Li JG: The extraction of true profiles for TPS commissioning and its impact on IMRT patient-specific QA. Med Phys 35(8):3661-3670 (2008) https://doi.org/10.1118/1.2952643
- Li JS, Lin T, Chen L, Price RA, Ma CM: Uncertainties in IMRT dosimetry. Med Phys 37:2491 (2010) https://doi.org/10.1118/1.3413997
- Ju SG, Han Y, Kum O, et al: Comparison of film dosimetry techniques used for quality assurance of intensity modulated radiation therapy. Med Phys 37(6):2925-2933 (2010) https://doi.org/10.1118/1.3395574
- Margalit DN, Chen YH, Catalano PJ, et al: Technological advancements and error rates in radiation therapy delivery. Int J Radiat Oncol Biol Phys 81(4):e673-679 (2011) https://doi.org/10.1016/j.ijrobp.2011.04.036
- Nelms BE, Simon JA: A survey on planar IMRT QA analysis. J Appl Clin Med Phys 8(3):2448 (2007)
- Kruse JJ: On the insensitivity of single field planar dosimetry to IMRT inaccuracies. Med Phys 37(6):2516-2524 (2010) https://doi.org/10.1118/1.3425781
- Nelms BE, Zhen H, Tomé WA: Per-beam, planar IMRT QA passing rates do not predict clinically relevant patient dose errors. Med Phys 38(2):1037-1044 (2011) https://doi.org/10.1118/1.3544657
- Stasi M, Bresciani S, Miranti A, Maggio A, Sapino V, Gabriele P: Pretreatment patient-specific IMRT quality assurance: a correlation study between gamma index and patient clinical dose volume histogram. Med Phys 39(12):7626-7634 (2012) https://doi.org/10.1118/1.4767763
- Li H, Dong L, Zhang L, Yang JN, Gillin MT, Zhu XR: Toward a better understanding of the gamma index: Investigation of parameters with a surface-based distance method. Med Phys 38(12):6730-6741 (2011) https://doi.org/10.1118/1.3659707
- Zhen H, Nelms BE, Tome WA: Moving from gamma passing rates to patient DVH-based QA metrics in pretreatment dose QA. Med Phys 38(10):5477-5489 (2011) https://doi.org/10.1118/1.3633904
- Olaciregui-Ruiz I, Rozendaal R, Mijnheer B, van Herk M, Mans A: Automatic in vivo portal dosimetry of all treatments. Phys Med Biol 58(22):8253-8264 (2013) https://doi.org/10.1088/0031-9155/58/22/8253
Cited by
- 다엽콜리메이터의 선량학적엽간격에 따른 치료계획 정도관리시스템의 효용성 평가 vol.26, pp.3, 2015, https://doi.org/10.14316/pmp.2015.26.3.168
- 다이나로그 파일을 이용한 부피세기조절회전치료의 정도관리 vol.39, pp.4, 2013, https://doi.org/10.17946/jrst.2016.39.4.13
- To propose adding index of achievement (IOA) to IMRT QA process vol.13, pp.None, 2013, https://doi.org/10.1186/s13014-018-1055-5
- 소프트웨어 기반 정도관리 시스템을 이용한 부피세기조절회전치료 환자 별 정도관리의 유용성 평가 vol.41, pp.1, 2013, https://doi.org/10.17946/jrst.2018.41.1.39