DOI QR코드

DOI QR Code

Balloon Occlusive Diameter of Non-Circular Atrial Septal Defects in Transcatheter Closure with Amplatzer Septal Occluder

  • Kim, Kwang Hoon (Department of Pediatrics, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Song, Jinyoung (Department of Pediatrics, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Kang, I-Seok (Department of Pediatrics, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Chang, Sung-A (Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Huh, June (Department of Pediatrics, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Park, Seung Woo (Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine)
  • Published : 2013.10.31

Abstract

Background and Objectives: The aim of this study was to investigate the balloon occlusive diameter (BOD) of non-circular defects in the transcatheter closure of atrial septal defect (ASD). Subjects and Methods: A total of 67 patients who had undergone transcatheter closure of an ASD were reviewed retrospectively. A noncircular defect was defined as the ratio of the short diameter to the long diameter of the defect on the en-face image less than 0.75. The BOD was compared with the long diameter of the defect and then compared between the two groups. Results: There were 22 patients with circular defects and 45 patients with non-circular defects. The difference in BOD measuring from the long diameter of the defect was quite different between the two groups and significantly smaller in non-circular morphology ($0.1{\pm}4.0$ vs. $2.3{\pm}2.1$, p=0.006). The difference in BOD measurement from the long diameter of ASD showed a positive correlation with the ratio of the short diameter to the long diameter of ASD (b/a) ($r^2$=0.102, p=0.008). In the non-circular morphology of ASD, the difference in BOD measured from the long diameter had a significant negative correlation with the long diameter of ASD ($r^2$=0.230, p=0.001), whereas in circular ASD, no significant correlation was found between the difference in BOD and the long diameter of ASD (p=0.201). Conclusion: The BOD compared with the long diameter measured from three-dimensional transesophageal echocardiography was smaller in non-circular ASD than in circular ASD. This difference was much smaller in non-circular ASD with a large long diameter.

Keywords

References

  1. Masura J, Gavora P, Podnar T. Long-term outcome of transcatheter secundum-type atrial septal defect closure using Amplatzer septal occluders. J Am Coll Cardiol 2005;45:505-7. https://doi.org/10.1016/j.jacc.2004.10.066
  2. Majunke N, Bialkowski J, Wilson N, et al. Closure of atrial septal defect with the Amplatzer septal occluder in adults. Am J Cardiol 2009;103:550-4. https://doi.org/10.1016/j.amjcard.2008.10.018
  3. Yew G, Wilson NJ. Transcatheter atrial septal defect closure with the Amplatzer septal occluder: five-year follow-up. Catheter Cardiovasc Interv 2005;64:193-6. https://doi.org/10.1002/ccd.20268
  4. Kim NK, Park SJ, Choi JY. Transcatheter closure of atrial septal defect: does age matter? Korean Circ J 2011;41:633-8. https://doi.org/10.4070/kcj.2011.41.11.633
  5. Johri AM, Witzke C, Solis J, et al. Real-time three-dimensional transesophageal echocardiography in patients with secundum atrial septal defects: outcomes following transcatheter closure. J Am Soc Echocardiogr 2011;24:431-7. https://doi.org/10.1016/j.echo.2010.12.011
  6. Roberson DA, Cui W, Patel D, et al. Three-dimensional transesophageal echocardiography of atrial septal defect: a qualitative and quantitative anatomic study. J Am Soc Echocardiogr 2011;24:600-10. https://doi.org/10.1016/j.echo.2011.02.008
  7. Ferreira SM, Ho SY, Anderson RH. Morphological study of defects of the atrial septum within the oval fossa: implications for transcatheter closure of left-to-right shunt. Br Heart J 1992;67:316-20. https://doi.org/10.1136/hrt.67.4.316
  8. van den Bosch AE, Ten Harkel DJ, McGhie JS, et al. Characterization of atrial septal defect assessed by real-time 3-dimensional echocardiography. J Am Soc Echocardiogr 2006;19:815-21. https://doi.org/10.1016/j.echo.2006.01.016
  9. Bhaya M, Mutluer FO, Mahan E, et al. Live/Real time three-dimensional transesophageal echocardiography in percutaneous closure of atrial septal defects. Echocardiography 2013;30:345-53. https://doi.org/10.1111/echo.12106
  10. Nasis A, Harper RW, Mottram PM. Real-time three-dimensional transoesophageal echocardiography for guidance of transcatheter closure of a complex multifenestrated atrial septal defect. Heart Lung Circ 2011;20:343-4. https://doi.org/10.1016/j.hlc.2011.01.005
  11. Marx GR, Fulton DR, Pandian NG, et al. Delineation of site, relative size and dynamic geometry of atrial septal defects by real-time three-dimensional echocardiography. J Am Coll Cardiol 1995;25:482-90. https://doi.org/10.1016/0735-1097(94)00372-W
  12. Huang X, Shen J, Huang Y, et al. En face view of atrial septal defect by two-dimensional transthoracic echocardiography: comparison to real-time three-dimensional transesophageal echocardiography. J Am Soc Echocardiogr 2010;23:714-21. https://doi.org/10.1016/j.echo.2010.04.016
  13. Seo JS, Song JM, Kim YH, et al. Effect of atrial septal defect shape evaluated using three-dimensional transesophageal echocardiography on size measurements for percutaneous closure. J Am Soc Echocardiogr 2012;25:1031-40. https://doi.org/10.1016/j.echo.2012.07.017
  14. Chan KC, Godman MJ, Walsh K, Wilson N, Redington A, Gibbs JL. Transcatheter closure of atrial septal defect and interatrial communications with a new self expanding nitinol double disc device (Amplatzer septal occluder): multicentre UK experience. Heart 1999;82:300-6. https://doi.org/10.1136/hrt.82.3.300
  15. Acar P. Three-dimensional echocardiography in transcatheter closure of atrial septal defects. Cardiol Young 2000;10:484-92.
  16. Ko SF, Liang CD, Yip HK, et al. Amplatzer septal occluder closure of atrial septal defect: evaluation of transthoracic echocardiography, cardiac CT, and transesophageal echocardiography. AJR Am J Roentgenol 2009;193:1522-9. https://doi.org/10.2214/AJR.09.2854
  17. Zanchetta M. On-line intracardiac echocardiography alone for Amplatzer Septal Occluder selection and device deployment in adult patients with atrial septal defect. Int J Cardiol 2004;95:61-8. https://doi.org/10.1016/j.ijcard.2003.04.022
  18. Amin Z, Hijazi ZM, Bass JL, Cheatham JP, Hellenbrand WE, Kleinman CS. Erosion of Amplatzer septal occluder device after closure of secundum atrial septal defects: review of registry of complications and recommendations to minimize future risk. Catheter Cardiovasc Interv 2004;63:496-502. https://doi.org/10.1002/ccd.20211
  19. Divekar A, Gaamangwe T, Shaikh N, Raabe M, Ducas J. Cardiac perforation after device closure of atrial septal defects with the Amplatzer septal occluder. J Am Coll Cardiol 2005;45:1213-8. https://doi.org/10.1016/j.jacc.2004.12.072
  20. Sadeghian H, Hajizeinali A, Eslami B, et al. Measurement of Atrial Septal Defect Size: A Comparative Study between Transesophageal Echocardiography and Balloon Occlusive Diameter Method. J Tehran Heart Cent 2010;5:74-7.