DOI QR코드

DOI QR Code

Improved Detection of Ischemic Heart Disease by Combining High-Frequency Electrocardiogram Analysis with Exercise Stress Echocardiography

  • Choi, Jin-Oh (Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Chang, Sung-A (Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Park, Sung Ji (Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Lee, Sang-Chol (Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Park, Seung Woo (Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine)
  • Published : 2013.10.31

Abstract

Background and Objectives: Because the exercise treadmill test (ETT) based on ST-segment analysis is limited due to low sensitivity and specificity, there has been an interest in the additional analysis of high-frequency components of QRS (HFQRS) for the detection of coronary artery disease (CAD). We sought to evaluate the feasibility and clinical usefulness of HFQRS analysis during exercise stress echocardiography (ESE). Subjects and Methods: We evaluated 175 patients (age $57{\pm}9$, 118 men) who performed ESE and either coronary computed tomographic angiography or coronary angiography. ETT was performed using the HyperQ stress system for both conventional ST-segment analysis and HFQRS intensity analysis. Results: Thirty-two patients (31%) had significant CAD. The sensitivity and specificity of HFQRS analysis were 68.8% and 74.8%, respectively. The combined model, including HFQRS analysis and ESE, provided the best diagnostic accuracy, with the area under the receiver-operating characteristics curve (AUC) of 0.948 {95% confidence interval (CI)=0.913-0.984} compared with ST-segment analysis (AUC 0.679, 95% CI=0.592-0.766). Conclusion: HFQRS analysis during ESE is feasible and may provide additional diagnostic information for the detection of significant CAD.

Keywords

References

  1. Gibbons RJ, Balady GJ, Bricker JT, et al. ACC/AHA 2002 guideline update for exercise testing: summary article: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee to Update the 1997 Exercise Testing Guidelines). Circulation 2002;106:1883-92. https://doi.org/10.1161/01.CIR.0000034670.06526.15
  2. Lucas FL, DeLorenzo MA, Siewers AE, Wennberg DE. Temporal trends in the utilization of diagnostic testing and treatments for cardiovascular disease in the United States, 1993-2001. Circulation 2006;113:374-9. https://doi.org/10.1161/CIRCULATIONAHA.105.560433
  3. Nedeljkovic I, Ostojic M, Beleslin B, et al. Comparison of exercise, dobutamine- atropine and dipyridamole-atropine stress echocardiography in detecting coronary artery disease. Cardiovasc Ultrasound 2006;4:22. https://doi.org/10.1186/1476-7120-4-22
  4. Abboud S, Cohen RJ, Selwyn A, Ganz P, Sadeh D, Friedman PL. Detection of transient myocardial ischemia by computer analysis of standard and signal-averaged high-frequency electrocardiograms in patients undergoing percutaneous transluminal coronary angioplasty. Circulation 1987;76:585-96. https://doi.org/10.1161/01.CIR.76.3.585
  5. Pettersson J, Pahlm O, Carro E, et al. Changes in high-frequency QRS components are more sensitive than ST-segment deviation for detecting acute coronary artery occlusion. J Am Coll Cardiol 2000;36:1827-34. https://doi.org/10.1016/S0735-1097(00)00936-0
  6. Schlegel TT, Kulecz WB, DePalma JL, et al. Real-time 12-lead high-frequency QRS electrocardiography for enhanced detection of myocardial ischemia and coronary artery disease. Mayo Clin Proc 2004;79:339-50. https://doi.org/10.4065/79.3.339
  7. Toledo E, Lipton JA, Warren SG, et al. Detection of stress-induced myocardial ischemia from the depolarization phase of the cardiac cycle--a preliminary study. J Electrocardiol 2009;42:240-7. https://doi.org/10.1016/j.jelectrocard.2008.12.023
  8. Sharir T, Merzon K, Kruchin I, et al. Use of electrocardiographic depolarization abnormalities for detection of stress-induced ischemia as defined by myocardial perfusion imaging. Am J Cardiol 2012;109:642-50. https://doi.org/10.1016/j.amjcard.2011.10.022
  9. Gianrossi R, Detrano R, Mulvihill D, et al. Exercise-induced ST depression in the diagnosis of coronary artery disease. A meta-analysis. Circulation 1989;80:87-98. https://doi.org/10.1161/01.CIR.80.1.87
  10. Higgins JP, Higgins JA. Electrocardiographic exercise stress testing: an update beyond the ST segment. Int J Cardiol 2007;116:285-99. https://doi.org/10.1016/j.ijcard.2006.04.047
  11. Kligfield P, Lauer MS. Exercise electrocardiogram testing: beyond the ST segment. Circulation 2006;114:2070-82. https://doi.org/10.1161/CIRCULATIONAHA.105.561944
  12. Okin PM, Kligfield P. Heart rate adjustment of ST segment depression and performance of the exercise electrocardiogram: a critical evaluation. J Am Coll Cardiol 1995;25:1726-35. https://doi.org/10.1016/0735-1097(95)00085-I
  13. Abboud S, Berenfeld O, Sadeh D. Simulation of high-resolution QRS complex using a ventricular model with a fractal conduction system. Effects of ischemia on high-frequency QRS potentials. Circ Res 1991;68:1751-60. https://doi.org/10.1161/01.RES.68.6.1751
  14. Abboud S, Cohen RJ, Sadeh D. A spectral analysis of the high frequency QRS potentials observed during acute myocardial ischemia in dogs. Int J Cardiol 1990;26:285-90. https://doi.org/10.1016/0167-5273(90)90084-I
  15. Mor-Avi V, Shargorodsky B, Abboud S, Laniado S, Akselrod S. Effects of coronary occlusion on high-frequency content of the epicardial electrogram and body surface electrocardiogram. Circulation 1987;76:237-43. https://doi.org/10.1161/01.CIR.76.1.237
  16. Abboud S. Subtle alterations in the high-frequency QRS potentials during myocardial ischemia in dogs. Comput Biomed Res 1987;20:384-95. https://doi.org/10.1016/0010-4809(87)90052-8
  17. Lauer M, Froelicher ES, Williams M, Kligfield P; American Heart Association Council on Clinical Cardiology, Subcommittee on Exercise, Cardiac Rehabilitation, and Prevention. Exercise testing in asymptomatic adults: a statement for professionals from the American Heart Association Council on Clinical Cardiology, Subcommittee on Exercise, Cardiac Rehabilitation, and Prevention. Circulation 2005;112:771-6. https://doi.org/10.1161/CIRCULATIONAHA.105.166543
  18. Froelicher VF, Lehmann KG, Thomas R, et al. The electrocardiographic exercise test in a population with reduced workup bias: diagnostic performance, computerized interpretation, and multivariable prediction. Veterans Affairs Cooperative Study in Health Services #016 (QUEXTA) Study Group. Quantitative Exercise Testing and Angiography. Ann Intern Med 1998;128(12 Pt 1):965-74. https://doi.org/10.7326/0003-4819-128-12_Part_1-199806150-00001
  19. Geleijnse ML, Fioretti PM, Roelandt JR. Methodology, feasibility, safety and diagnostic accuracy of dobutamine stress echocardiography. J Am Coll Cardiol 1997;30:595-606. https://doi.org/10.1016/S0735-1097(97)00206-4

Cited by

  1. A DETECTION SYSTEM OF EXERCISE ELECTROCARDIOGRAM vol.27, pp.4, 2013, https://doi.org/10.1590/1517-8692202127042021_0122