Errors of Proportional Shifting due to Simplified Equivalent Circuit of a 3-Phase Induction Motor

3상유도전동기의 간이등가회로에 의한 비례추이 오차

  • Shin, Myoung-Ho (Dept. of Electrical and Information Engineering, Seoul Nat'l Univ. of Science and Technology)
  • 신명호 (서울과학기술대학교 전기정보공학과)
  • Received : 2012.12.20
  • Accepted : 2013.01.03
  • Published : 2013.01.31

Abstract

It is well known that the maximum torque of a 3-phase induction motor does not vary as the resistance of rotor varies by proportional shifting. However, proportional shifting is derived using simplified equivalent circuit of induction motor. Therefore, there are some errors in the torque characteristics shown in the text book. This paper presents the torque characteristics using not simplified equivalent circuit but equivalent circuit. Errors produced by simplified equivalent circuit are presented.

Keywords

References

  1. M-H. Shin, "Maximum efficiency control of a stator flux-oriented induction motor drive" Journal of KIIEE, vol. 20, no. 4, pp. 117-122, 2006. https://doi.org/10.5207/JIEIE.2006.20.4.117
  2. Myoung-Ho Shin, "Analysis on Parameter Detuning of Induction Motor Drives in Field Weakening Region", Journal of KIIEE, vol. 24, no. 9, pp. 118-123, 2010. https://doi.org/10.5207/JIEIE.2010.24.9.118
  3. Yoon-Jong Lee, "Electric Machinery" Dongmyoung Press, Korea, pp. 285-286, 2001.
  4. Stephen J. Champan, "Electric Machinery Fundamentals", 5th Edition, McGraw-Hill Korea, 2012.
  5. Energy Conversion Lab. of Hanyang Univ., "Electric Machinery", 2nd Edition, Hongneung Science Press, Korea,pp.373, 2011.
  6. A. M. Trzynadlowski, "The Field Orientation Principle in Control of Induction Motors", Kluwer Academic Publishers, Massachusetts USA, pp.1-38, 1994.

Cited by

  1. An Analysis on a Torque Error of a 3-Phase Induction Motor due to Simplified Equivalent Circuit vol.28, pp.1, 2014, https://doi.org/10.5207/JIEIE.2014.28.1.045