References
- Hartzler GO, Rutherford BD, McConahay DR. Retained percutaneous transluminal coronary angioplasty equipment components and their management. Am J Cardiol 1987;60:1260-4. https://doi.org/10.1016/0002-9149(87)90604-7
- Khonsari S, Livermore J, Mahrer P, Magnusson P. Fracture and dislodgment of floppy guidewire during percutaneous transluminal coronary angioplasty. Am J Cardiol 1986;58:855-6. https://doi.org/10.1016/0002-9149(86)90370-X
- Woodfield SL, Lopez A, Heuser RR. Fracture of coronary guidewire during rotational atherectomy with coronary perforation and tamponade. Cathet Cardiovasc Diagn 1998;44:220-3. https://doi.org/10.1002/(SICI)1097-0304(199806)44:2<220::AID-CCD20>3.0.CO;2-P
- Al-Amri HS, AL-Moghairi AM, Calafiore AM. Left main approach for retrieval of retained guidewire fragment. J Card Surg 2012;27:307-8. https://doi.org/10.1111/j.1540-8191.2011.01352.x
- van Gaal WJ, Porto I, Banning AP. Guide wire fracture with retained filament in the LAD and aorta. Int J Cardiol 2006;112:e9-11. https://doi.org/10.1016/j.ijcard.2006.01.040
- Hong YM, Lee SR. A case of guide wire fracture with remnant filaments in the left anterior descending coronary artery and aorta. Korean Circ J 2010;40:475-7. https://doi.org/10.4070/kcj.2010.40.9.475
- Alexiou K, Kappert U, Knaut M, Matschke K, Tugtekin SM. Entrapped coronary catheter remnants and stents: must they be surgically removed? Tex Heart Inst J 2006;33:139-42.
- Kim JH, Kim GH, Moon KW. Successful transradial retrieval of broken catheter fragment during transradial coronary angiography. J Invasive Cardiol 2012;24:74-5.
- Karabulut A, Daglar E, Cakmak M. Entrapment of hydrophilic coated coronary guidewire tips: which form of management is best? Cardiol J 2010;17:104-8.
- Collins N, Horlick E, Dzavik V. Triple wire technique for removal of fractured angioplasty guidewire. J Invasive Cardiol 2007;19:E230-4.
- Cho YH, Park S, Kim JS, et al. Rescuing an entrapped guidewire using a Tornus catheter. Circ J 2007;71:1326-7. https://doi.org/10.1253/circj.71.1326
- Kim JY, Yoon J, Jung HS, et al. Broken guidewire fragment in the radio- brachial artery during transradial sheath placement: percutaneous retrieval via femoral approach. Yonsei Med J 2005;46:166-8. https://doi.org/10.3349/ymj.2005.46.1.166
- Kang JH, Rha SW, Lee DI, et al. Successful retrieval of a fractured and entrapped 0.035-inch terumo wire in the femoral artery using biopsy forceps. Korean Circ J 2012;42:201-4. https://doi.org/10.4070/kcj.2012.42.3.201
- Darwazah AK, Abu Sham'a RA, Yassin IH, Islim I. Surgical intervention to remove an entrapped fractured guidewire during angioplasty. J Card Surg 2007;22:526-8. https://doi.org/10.1111/j.1540-8191.2007.00462.x
Cited by
- 경피적 관상동맥 확장 성형술 도중 우관상동맥 뒤가쪽가지에서 발생한 유도철사 부러짐 vol.33, pp.1, 2016, https://doi.org/10.12701/yujm.2016.33.1.52
- Lost in circulation vol.35, pp.8, 2013, https://doi.org/10.1111/jocs.14821
- Device entrapment during percutaneous coronary intervention of chronic total occlusions: incidence and management strategies vol.17, pp.3, 2013, https://doi.org/10.4244/eij-d-20-00781