Indoor Air Flow Pattern in the Mixed-Use Apartment with Double Window System

이중창호 시스템이 적용된 주상복합건물의 실내 기류특징 분석

  • 정창헌 (경남과학기술대학교 건축공학과) ;
  • 김태연 (연세대학교 건축공학과) ;
  • 이승복 (연세대학교 건축공학과) ;
  • 황석호 (경남대학교 건축학부)
  • Received : 2013.08.13
  • Published : 2013.12.25

Abstract

The purpose of this study is to evaluate the ventilation performance of Double Window System in the mixed-use apartment by CFD simulation. The average indoor air speed and PMV are the performance indicators of the study. Indoor air speed and PMV of target building is determined and compared in each case of double window and single window. According to the preliminary analysis of the air flow transmission through each window system in the pressure difference of 10 Pa, double window system shows the larger range of airflow than the conventional project type window system. When the double window system implemented to the mixed-use apartment, indoor air speed increased to 127% in the maximum ventilation mode. In minimum ventilation mode, indoor air speed is 67% of project window system. In the respect of thermal comfort, PMV slightly reduced by 0 ~ 0.2 with the increased air flow speed by the application of double window system. These results indicate the restricted usefulness of the double window system in the respect of the occupants' thermal perception.

Keywords

Acknowledgement

Supported by : 국토해양부

References

  1. Kimura K. Effect of ventilative cooling on indoor environment. Proc. Int. Symp. Room Air Convention and Ventilatio Effectiveness, Univ. of Tokyo, p.p. 578-583, 1992
  2. Givoni, Climate and Architecture. Applied Science, London, 1969
  3. 김진효, 조현, 이종인, 김유신, 정재원, 초고층 공동주택 거주자들의 전열교환형 환기장치 운전방식 현황 조사 및 문제점 분석, 대한건축학회 논문집 - 계획계 25(2), 2009.2, 249-256
  4. 조진균, 홍민호, 유창우, 자연환기 계획을 위한 국내 초고층 공동주택 커튼월의 창호유형 사례분석 및 환기창 성능분석에 관한 연구, 대한건축학회 논문집 - 계획계 25(4), 2009.4, 253-261
  5. 권용일, 장상규, 김선정, 주상복합건물의 창호개폐길이가 자연 환기능력에 미치는 영향에 관한 연구, 대한설비공학회 학술발표대회논문집, 2011.7, 1162-1167
  6. 노상태, 김강수, Single-sided 개구부의 형태와 위치에 따른 자연환기 특성에 관한 연구, 대한건축학회논문집(계획계), v.21 n.8, 2005. 08
  7. 정창헌, 김지영, 황석호, 박병용, 김태연, 이승복, 공동주택 내쾌적환기 운전 조건에 따른 환기특성 분석, 대한건축학회 논문집 - 계획계 26(1), 2010.1, 331-339
  8. 김형근, 문정만, 최용석, 자연환기덕트를 통한 초고층 공동주 택의 환기성능 분석, 대한건축학회 논문집 - 계획계 27(9), 2011.9, 309-316
  9. 김선숙, 이윤규, 자연환기설비의 성능항목 분석 및 환기성능 평가에 관한 연구, 대한건축학회 논문집 - 계획계 24(12), 2008.12, 295-302
  10. Ali Fallahi, Fariborz Haghighat, Hafia Elsadi. Energy performance assessment of double-skin facade with thermal mass, Energy and Buildings, Volume 42, Issue 9, September 2010, Pages 1499-1509 https://doi.org/10.1016/j.enbuild.2010.03.020
  11. Neveen Hamza. Double versus single skin facades in hot arid areas, Energy and Buildings, Volume 40, Issue 3, 2008
  12. Juan Zhou, Youming Chen. A review on applying ventilated double-skin facade to buildings in hot-summer and cold-winter zone in China, Renewable and Sustainable Energy Reviews, Volume 14, Issue 4, May 2010, Pages 1321-1328 https://doi.org/10.1016/j.rser.2009.11.017
  13. Volker Huckemann, Ernesto Kuchen, Marlon Leao, Erika F.T.B. Leao. Empirical thermal comfort evaluation of single and double skin facades, Building and Environment, Volume 45, Issue 4, April 2010, Pages 976-982 https://doi.org/10.1016/j.buildenv.2009.10.006
  14. 최석용, 이정재, 최진혁, 김용경, 이성진, 현장실험을 통한 박스형 이중외피시스템의 환경성능평가, 대한건축학회 논문집 - 계획계 25(1), 2009.1, 287-294
  15. 소재현, 김우태, 식물공장 이중창호의 하절기 열전달 성능 분석, 대한설비공학회, 설비공학논문집 24(4), 2012.4, 351-357
  16. 정창헌, 황석호, 김태연, 이승복, 이중창호의 하절기 냉방부하 저감 가능성에 대한 기초적 연구, 대한건축학회 논문집 - 계획계 26(2), 2010.2, 275-282
  17. 이승재, 공동주택에서의 이중창호 시스템을 통한 자연환기도입이 실내 온열환경에 미치는 영향 평가에 관한 연구, 연세대학교 석사학위논문, 2010.12
  18. 최태환, 김태연, 이승복, 수치해석을 이용한 자연환기설비의 환기량 해석에 관한 연구, 대한건축학회 논문집 - 계획계 23(9), 2007.9, 181-188
  19. The 2001 ASHRAE Handbook: Fundamentals
  20. Cândido, C., R. J. de Dear, R. Lamberts and L. Bittencourt. 2010. "Air movement acceptability limits and thermal comfort in Brazil's hot humid climate zone". Building and Environment, 45(1): 222-229 https://doi.org/10.1016/j.buildenv.2009.06.005
  21. Arens E, T. S., Zhang H, Paliaga G. 2009. "Moving air for comfort". ASHRAE Journal: 18-29.
  22. 배누리, 전정윤, 여름철 집합주택의 거실 온열 환경의 측정 및 거주자의 냉방기 사용행위에 관한 연구, 한국주거학회 학술발표대회자료 2004, 323-328 , 2004
  23. Davenport, A.G., "A Rationale for the Determination of Design Wind Velocities", Proceedings ASCE Structural Division, 86: 39-66, 1960.