Optimum Binder Ratio of Mass Concrete for LNG Tank

LNG저장시설 적용을 위한 매스콘크리트 최적 결합재 혼입율 검토

  • Received : 2013.12.06
  • Accepted : 2013.12.19
  • Published : 2013.12.30

Abstract

The optimum binder ratio of the low heat mass concrete for LNG tank was evaluated in the present study. Three types of binder such as OPC I, ground granulated blast-furnace slag powder were mixed and were used. Also fine particle cement and activator were used to raise an early age strength development and ground limestone was used to reduce the cost. As a result of the study, mix ratio II (30:30:40) was suitable for Bottom Center and mix ratio III(40:30:30) was suitable for Roof based on compressive strength and semi-adiabatic temperature.

본 연구에서는 LNG저장시설용 수화열 저감형 콘크리트 적용을 위하여 최적의 결합재를 개발하고자 하였다. 결합재는 1종포틀랜드시멘트, 고로슬래그미분말, 플라이애시를 혼합 사용하였다. 또한 여기에 미립자시멘트 및 자극제를 첨가하여 조강성능 향상 및 석회석 고미분말을 사용하여 경제성을 향상시켰다. 검토결과, 압축강도 및 간이 수화열 실험 결과를 종합해 볼 때, Bottom Center의 경우 혼입비율 II(30:30:40), Roof의 경우 혼입비율 III(40:30:30)이 최적 혼입비율인 것으로 평가되었다.

Keywords

References

  1. Korea Concrete Institute (2009). Concrete standard specification, Korea Concrete Institute.
  2. Architectural Institute of Korea (2006). Standard Specification for Building Construction, Architectural Institute of Korea.
  3. Han C.G. (2011) Concrete Properties and Mix design, Kimoondang.
  4. Byun K.J., Kim J.H., Nam J.W. and Kim H.J. (2007) Kimoondang
  5. Korea Concrete Institute (2001). Concrete Admixture, Korea Concrete Institute.
  6. Korea Concrete Institute (2005). Concrete Engineering, Korea Concrete Institute.
  7. Korea Concrete Institute (2004). Special Concrete Engineering, Korea Concrete Institute.
  8. ACI committee 232 (2003) Use of fly ash in concrete, America Concrete Institute.
  9. Kim J.K. and Yang E.I. (1997) Factors for Hydration Heat and Thermal Stress in Mass Concrete, Korea Concrete Institute Journal, 9(3), 15-2.
  10. Park C.K., Son S.H., Lee S.H., Jang K.W., Jeong J.H. and Kim M.S. (2001) Hydartion Heat Control with Closed Loop Pipe Cooling System, KCI Autumn Conference, 13(2), 403-408.
  11. Lee J.H,, Bae H.U., Woo S.M., Woo J.I., Ha B.T. and Kim J.S. (2002) Study on thermal crack control using pipe-cooling in massive concrete foundation of urban bridge, KCI Spring Conference, 14(1), 41-46.
  12. Kim Y.J., Lee S.S. and Lee S.H. (2000) Crack Control of RC Structures Using the Low Heat Concrete Mixed with Fly Ash, Korea Concrete Institute Journal, 12(2), 41-47.
  13. Kim K.H., Hwang I.S., Kwon O.B., Kim K.M., and Park S.J. (2010) A Study on the Fundamental Properties of Low Carbon Low Heat Concrete according to Replacement Ratio of Mineral Admixture, KCI Autumn Conference, 22(2), 71-72.
  14. Lee I.S., Hong S.M., Baek D.H., Kim K.H., Han M.C. and Han C.K. (2009) Characteristics the Concrete According to Mixing Methods and Unit Water Content of Ternary Blended Cement, KIC Autumn Conference, 9(2), 133-136.
  15. Choi S.Y., Kim S.H., Cha W.H. Kwon O.B., Han M.C. and Han C.K. (2007) Properties of High Strength Concrete Depending on the Blaine of Cement Particle Classifying, KIC Spring Conference, 7(1), 71-74.
  16. Kim S.I., Kim K.H., Bae J.C., Lee H.I., Kim S.S. and Han C.K. (2007) Effect of the Various Combinations of the Binders and the Silica Fume Types to the Physical Properties of the Pre-Mix Cement, KIC Autumn Conference, 7(2), 37-40.
  17. Kim K.H., Hwang I.S., Kim S.S., Choi S.Y., Han M.C. and Han C.K., The Influence of the Type of Silica Fume on the Property of Cement Binder for Ultra High Strength (2007) KIC Spring Conference, 7(1), 51-54.