DOI QR코드

DOI QR Code

Energy demand analysis according to window size and performance for Korean multi-family buildings

  • Huh, Jung-Ho (Department of Architectural Engineering, University of Seoul) ;
  • Mun, Sun-Hye (Department of Architectural Engineering, University of Seoul)
  • Received : 2013.08.30
  • Accepted : 2013.12.05
  • Published : 2013.12.30

Abstract

Special attention is required for the design of windows due to their high thermal vulnerability. This paper examines the problems that might arise in the application of the u-value, by reflecting the changes in the u-value of the window, depending on the window-to-wall ratio obtained in an energy demand analysis. Research indicates that the u-value of a window increases with an increase in the difference between the u-values of the frames and the glass. Relative to the changes in the u-value of the windows, the energy demand varied from 1.3% to 9.3%. Windows with a g-value of 0.3 or 0.5 displayed a higher energy demand than windows with a g-value of 0.7. Therefore, when the difference between the performance of the glass and the frame is significant, especially when the g-value is small, a modified heat transmission coefficient should be applied to the window size during the evaluation of the building energy demand.

Keywords

References

  1. ANSI/ASHRAE/IESNA Standards 90.1- 2004. (2004) "Energy Standard for Buildings Low-Rise Residential Buildings." American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc. Atlanta.
  2. Cappelletti, F., et al. (2011) "Analysis of the influence of installation thermal bridges on windows performance: The case of clay block walls." Energy and Buildings, 43(6), 1435-1442. https://doi.org/10.1016/j.enbuild.2011.02.004
  3. EN ISO 10077-1. (2006) "Thermal performance of windows, doors and shutters - Calculation of thermal transmittance-Part1:General."
  4. EN ISO 10077-2. (2003) "Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 2:Numerical method for frames."
  5. EN ISO 15927-4 (2005) "Hygrothermal performance of buildingscalculation and presentation of climatic data-Part4: Data for assessing the annual energy for heating and cooling."
  6. EPBD. (2010) "Directive 2010/31/EU of the European parliament and of the council of 19 may 2010 on the energy performance of buildings." Official Journal of the European Union.
  7. Gasparella, A., et al. (2011) "Analysis and modelling of window and glazing systems energy performance for a well insulated residential building." Energy and Buildings, 43(4), 1030-1037. https://doi.org/10.1016/j.enbuild.2010.12.032
  8. Ghisi, E., and John A. Tinker. (2005) "An ideal window area concept for energy efficient integration of daylight and artificial light in buildings." Building and Environment, 40(1), 51-61. https://doi.org/10.1016/j.buildenv.2004.04.004
  9. Ihm, P., et al. (2012) "Impact of window selection on the energy performance of residential buildings in South Korea." Energy Policy, 44, 1-9. https://doi.org/10.1016/j.enpol.2011.08.046
  10. Jaber, S. and Ajib S. (2011) "Thermal and economic windows design for different climate zones." Energy and Buildings, 43(11), 3208-3215. https://doi.org/10.1016/j.enbuild.2011.08.019
  11. Lee, et al. (2010) "Generation of typical weather data using the ISO Test Reference Year (TRY) method for major cities of South Korea." Building and Environment, 45, 956-963. https://doi.org/10.1016/j.buildenv.2009.10.002
  12. MOLIT(Ministry of Land, Infrastructure and Transport) (2012) [online]. Available from: www.molit.go.kr.
  13. Nielsen, T., Duer, K., and Svendsen, S. (2001) "Energy performance of glazings and windows." Solar Energy, 69(6), 137-143. https://doi.org/10.1016/S0038-092X(01)00062-7
  14. Su, X. and Xu, Z. (2010) "Environmental performance optimization of window-wall ratio for different window type in hot summer and cold winter zone in China based on life cycle assessment." Energy and Buildings, 42(2), 198-202. https://doi.org/10.1016/j.enbuild.2009.08.015
  15. Tsikaloudaki, K., et al. (2012) "Assessing cooling energy performance of windows for of f ice buildings in the mediterranean zone." Energy and Buildings, 49, 192-199. https://doi.org/10.1016/j.enbuild.2012.02.004
  16. Urbikain, M. and Sala, J. (2009) "Analysis of different models to estimate energy savings related to windows in residential buildings." Energy and Buildings, 41(6), 687-695. https://doi.org/10.1016/j.enbuild.2009.01.007