건강한 너구리(Nyctereutes procyonoides)들의 심전계 지표에 대한 평가

Evaluation of Electrocardiographic Index in Healthy Raccoon Dogs (Nyctereutes procyonoides)

  • 홍원우 (강원대학교 수의학과 야생 동물의학실) ;
  • 김종택 (강원대학교 수의학과 야생 동물의학실) ;
  • 양동근 (농림수산검역검사본부) ;
  • 남효승 (강원대학교 수의학과 소동물 내과교실) ;
  • 현창백 (강원대학교 수의학과 소동물 내과교실)
  • Hong, Won-Woo (Section of Wildlife Medicine, College of Veterinary Medicine, Kangwon National University) ;
  • Kim, Jong-Taek (Section of Wildlife Medicine, College of Veterinary Medicine, Kangwon National University) ;
  • Yang, Dong-Keun (Viral Disease Division, Animal, Plant and Fishery Quarantine Inspection Agency) ;
  • Nam, Hyo-Seung (Section of Small Animal Internal Medicine, College of Veterinary Medicine, Kangwon National University) ;
  • Hyun, Changbaig (Section of Small Animal Internal Medicine, College of Veterinary Medicine, Kangwon National University)
  • 심사 : 2013.12.11
  • 발행 : 2013.12.31

초록

포획된 건강한 너구리들의 심전도의 기준값을 평가하는 것이 본 논문의 주된 목적이다. 41마리의 방목되고 있는 다 자란 너구리들이 강원대학교 야생동물구조센터에 의해 구조되었으며 본 논문에 이용되었다. 어떠한 화학적 보정도 사용하지 않고 6-유도 심전도를 측정하였다. 평균 심박수는 $146.10{\pm}43.31$ 박동수/분 이었다(95% 신뢰구간 132.84~159.36 박동수/분). 평균 호흡수는 $35.73{\pm}11.56$ 호흡수/분 이었다(95% 신뢰구간 32.19~39.27 호흡수/분). 평균 수축기 압력은 $136{\pm}29.26mmHg$ 이었다(95% 신뢰구간 127.99~145.91 mmHg). 모든 너구리들의 심전계의 특징들을 또한 평가하였다. P-파의 평균 너비와 높이는 $38.2{\pm}4.0ms$ (범위 28-40 ms) 와 $0.128{\pm}0.039mV$ (범위 0.09~0.20)이었다. QRS파의 평균 너비와 높이는 $48.5{\pm}7.2ms$ (범위 36-60 ms) 와 $1.330{\pm}0.650mV$ (범위 0.15~2.30)이었다. 평균전기축 (QRS)은 $-91^{\circ}{\sim}+96^{\circ}$ ($10^{\circ}{\sim}60^{\circ}$; 95% 신뢰구간)이었다. 평균 교정 QT 간격(QTc)은 $273.7{\pm}32.7ms$ (범위 212-333 ms)이었고, PR간격은 $76.1{\pm}10.0ms$ (범위 50-82 ms)이었다. 본 논문은 포획된 건강한 너구리들의 심전도(ECG)의 기준값을 제공하는 최초의 논문이다.

The aim of this study is to evaluate the reference value for electrocardiogram in healthy captive raccoon dogs. Forty-one free-ranging adult raccoon dogs rescued from Wildlife rescue centre, Kangwon National University were enrolled in this study. The 6-lead electrocardiogram was obtained in all raccoon dogs without any chemical restraints. The mean heart rate was $146.10{\pm}43.31$ beats/min (95% confidence interval 132.84~159.36 beats/min). The mean respiration rate was $35.73{\pm}11.56$ breaths/min (95% confidence interval 32.19~39.27 breaths/min). The mean systolic blood pressure was $136{\pm}29.26$ mmHg (95% confidence interval 127.99~145.91 mmHg). Electrocardiographical features were also evaluated in all raccoon dogs. The mean duration and amplitude of P-wave were $38.2{\pm}4.0$ ms (range 28-40 ms) and $0.128{\pm}0.039$ mV (range 0.09~0.20). The mean duration and amplitude of QRS complexes were $48.5{\pm}7.2ms$ (range 36-60 ms) and $1.330{\pm}0.650$ mV (range 0.15~2.30). The range of the mean electrical (QRS) axis was $-91^{\circ}{\sim}+96^{\circ}$ ($10^{\circ}{\sim}60^{\circ}$; 95% of confidence interval). The mean corrected QT (QTc) interval was $273.7{\pm}32.7ms$ (range 212-333 ms), while the mean PR interval was $76.1{\pm}10.0ms$ (range 50-82 ms). To the authors' knowledge, this is the first study to provide references in electrocardiogram (ECG) in healthy captive raccoon dogs.

키워드

참고문헌

  1. Ettinger SJ, Feldman EC. Electrocardiography and Cardiac Arrhythmias. In: Textbook of Veterinary Internal Medicine. Philadelphia: Elsevier Saunders. 2004: 1040-1076.
  2. Hamlin RL, Hren J, Sparrow PV. Electrocardiographic evaluation of the healthy raccoon (Procyon lotor). Am J Vet Res 1986; 47: 814-817.
  3. O S-Y. Detection of antibody against rabies virus and blood analysis in Korean raccoon dogs (Nyctereutes procyonoides koreensis). PhD Thesis, Seoul National University. 2011: 18-21.
  4. Ruo JI. Study of ecology, hematologic and serum biochemistry value in Korean wild raccoon dog (Nyctereutes procyonoides). PhD Thesis, Seoul National University. 2008: 9-24.